Listing ID #3766199
Company Information
Ask for more detail from the seller
Contact SupplierThe Fluke 317 are designed with ergonomic concepts, shaped to fit your hand and to access tight spots easily. The Fluke 317 also offer AC/DC current measurements and have a higher resolution for loads below 40 A. In addition to a compact package with a strong feature set, and Frequency functions for testing motors, lighting, etc.
These affordable instruments combine a compact package with a strong feature set:
The Meter ships with:
Current AC | Range | 40.00 A, 600.0 A |
Resolution | 0.01 A, 0.1 A | |
Accuracy | 1.6% ± 6 digit (50-60 Hz) {40 A} | |
2.5% ± 8 digit (60-500 Hz) {40 A} | ||
1.5% ± 5 digit (50-60 Hz) {600 A} | ||
2.5% ± 5 digit (60-500 Hz) {600 A} | ||
Crest Factor add 2% into spec for CF > 2 | 3.0 Max @ 500 A, 2.5 Max @ 600 A | |
AC response | rms | |
Current DC | Range | 40.00 A, 600.0 A |
Resolution | 0.01 A, 0.1 A | |
Accuracy | 1.6% ± 6 digit (40 A) | |
1.5% ± 5 digit (600 A) | ||
Voltage AC | Range | 600.0 V |
Resolution | 0.1 V | |
Accuracy | 1.5% ± 5 digit (20-500Hz) | |
AC response | rms | |
Voltage DC | Range | 600.0 V |
Resolution | 0.1 V | |
Accuracy | 1% ± 4 digit | |
Resistance | Range | 400.0 Ω, 4000 Ω |
Resolution | 0.1 Ω, 1 Ω | |
Accuracy | 1% ± 5 digit | |
Continuity | ≤ 30 Ω | |
Inrush | Integration time | N/A |
Frequency | Range | N/A |
Accuracy | N/A | |
Trigger Level | N/A |
Operating Temperature | 14°F to 122°F (-10 °C to 50 °C) |
Storage Temperature | -40 °F to 140 °F (-40 °C to 60 °C) |
Operating Humidity | Non condensing (< 50 °F) (< 10 °C) |
90 % RH (50 °F to 86 °F) (10 °C to 30 °C) | |
75 % RH (86 °F to 104 °F) (30 °C to 40 °C) | |
45 % RH (104 °F to 122 °F) (40 °C to 50 °C) | |
(Without Condensation) | |
Operating Altitude | 1 mile (2000 meters) above mean sea level |
Storage Altitude | 7 miles (12,000 meters) above mean sea level |
IP Rating | IP40 |
Vibration Requirements | Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis |
Drop Test Requirements | 3 ft (1 m) drop test, six sides, oak floor |
EMI, RFI, EMC | Instrument unspecified for use in EMC field ≥ 0.1 V/m |
Temperature Coefficients | 0.1x (specified accuracy)/ °C |
(<64 °F or > 82° F) | |
(<18 °C or > 28 °C) |