Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    Basic Auramine

    • Melting Point267C (513F)
    • Number Of FlowerChemical Dye
    • Chemical FormulaC17H21N3ClH
    • Storage Color CodeGreen
    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 17 Years
    • building Nature of Business Retailer
    • Year of Establishment 1988

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details

    Product Details no_img_icon

    • Number Of FlowerChemical Dye
    • Melting Point267C (513F)
    • SolubilitySoluble In Water
    • Flammability RatingSlight
    • Personal ProtectionUse Appropriate Respirators, Protective Clothing, And Eye Protection
    • SynonymsAuramine O, CI 41000, Auramine Hydrochloride
    • Chemical FormulaC17H21N3ClH
    • Molecular Weight303.84
    • Reactivity RatingNone
    • Storage Color CodeGreen
    • Health RatingModerate

    Mehul Dye Chem. Industries is the one name, which is look after for the manufacturing and exporting of Basic Auramine O. Our manufactured Basic Auramine O is known for its accurate chemical specifications, which makes it worthy to apply in varied industrial processes.
    Physical and Chemical Properties :
    Appearance : Yellow needlesSolubility : Soluble in waterpH : No information foundBoiling Point : No information foundMelting Point : 267C (513F)
    Product Identification :
    Synonyms : Auramine O, biological stain; CI 41000; aniline,4,4'- (Imidocarbonyl) Bis (N,N- Dimethyl-, hydrochloride; Auramine hydrochloride; CI basic yellow #2Molecular Weight : 303.84Chemical Formula : C17H21N3ClH
    Exposure Controls/Personal Protection :
    Airborne Exposure Limits : None established.
    Personal Respirators (NIOSH Approved) : For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator (NIOSH type N95 or better filters) may be worn. If oil particles (e.g. lubricants, cutting fluids, glycerin, etc.) are present, use a NIOSH type R or P filter. For emergencies or instances where the exposure levels are not known, use a full-face positive-pressure, air-supplied respirator. WARNING: Air-purifying respirators do not protect workers in oxygen-deficient atmospheres.
    Disclaimer :
    Harmful if swallowed or absorbed through skinMay cause irritation to skin, eyes, and respiratory tractAvoid breathing dust.Avoid contact with eyes, skin, and clothing.Keep container closed.Use with adequate ventilationSkin Protection : Wear impervious protective clothing, including boots, gloves, lab coat, apron, or coveralls, as appropriate, to prevent skin contact.Eye Protection : Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is possible. Use chemical safety goggles.
    Handling and Storage
    Keep in a tightly closed container, stored in a cool, dry, ventilated area. Protect against physical damage. Separate from incompatibilities. Containers of this material may be hazardous when empty since they retain product residues (dust, solids); observe all warnings and precautions listed for the product.
    SAF-T-DATA(tm) Ratings :
    Health Rating : 2 - ModerateFlammability Rating : 1 - SlightReactivity Rating : 0 - NoneContact Rating : 2 - Moderate (Life)Lab Protective Equip. : GOGGLES; LAB COAT; VENT HOOD; PROPER GLOVESStorage Color Code : Green (General Storage)
    First Aid Measures :
    Inhalation : Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Call a physician.Ingestion : Give large amounts of water to drink. Never give anything by mouth to an unconscious person. Get medical attention.Skin Contact : In case of contact, immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Wash clothing before reuse. Call a physician.Eye Contact : In case of contact, immediately flush eyes with plenty of water for at least 15 minutes, lifting upper and lower eyelids occasionally. Call a physician if irritation persists.
    Fire Fighting Measures :
    Fire : As with most organic solids, fire is possible at elevated temperatures or by contact with an ignition source.Explosion : Fine dust dispersed in air in sufficient concentrations, and in the presence of an ignition source is a potential dust explosion hazard.Fire Extinguishing Media : Water spray, dry chemical, alcohol foam, or carbon dioxide.Special Information : In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full facepiece operated in the pressure demand or other positive pressure mode.
    Accidental Release Measures
    Remove all sources of ignition. Ventilate area of leak or spill. Wear appropriate personal protective equipment as specified in Section 8. Spills: Clean up spills in a manner that does not disperse dust into the air. Use non-sparking tools and equipment. Reduce airborne dust and prevent scattering by moistening with water. Pick up spill for recovery or disposal and place in a closed container.
    Exposure Controls/Personal Protection :
    Ventilation System : A system of local and/or general exhaust is recommended to keep employee exposures as low as possible. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area. Please refer to the ACGIH document, Industrial Ventilation, A Manual of Recommended Practices, most recent edition, for details. Personal Respirators (NIOSH Approved) : For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator (NIOSH type N95 or better filters) may be worn. If oil particles (e.g. lubricants, cutting fluids, glycerine, etc.) are present, use a NIOSH type R or P filter. For emergencies or instances where the exposure levels are not known, use a full-face positive-pressure, air-supplied respirator. WARNING: Air-purifying respirators do not protect workers in oxygen-deficient atmospheres.Skin Protection : Wear impervious protective clothing, including boots, gloves, lab coat, apron or coveralls, as appropriate, to prevent skin contact.Eye Protection : Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is possible. Use chemical safety goggles.


    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Basic Auramine?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice