Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Electric Cast Iron Inline Flow Meter

Listing ID #5811027

  • MaterialCast Iron
  • Packaging TypePacked In Corrugated Boxes
  • Driven TypeElectric
  • Accuracy1.0% Of Reading At Rates > 0.5m/s 0.005 M/s Of Reading At Rates < 0.5m/s
  • Supply Type Exporter, Supplier
Preferred Buyer From : All over the world
View More Details
Send Enquiry

Company Information

  • Member Since 6 Years
  • Nature of Business Retailer
  • GST No. 36AAOFN3614M1ZV

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Material Cast Iron
  • Packaging Type Packed In Corrugated Boxes
  • Driven Type Electric
  • Accuracy 1.0% Of Reading At Rates > 0.5m/s 0.005 M/s Of Reading At Rates < 0.5m/s
  • Connection Clamp
  • Measuring Principle. Transit Time Difference
  • Warranty 1 Year

Details :

  • Excellent long-term stability
  • Best accuracy among the three transducer types
  • Flowmeter is pre-programmed in factory, thus, it is a simple plug and play device
  • For pipe size DN10~DN500 (3/8”~20”)

 

Ultrasonic flow measurement is among the best & most accurate technology available these days. It is widely accepted & prominently used across the industries due to its non-cohesive nature with the flow media. It is also non-effected in high magnetic field zones, where other technologies like electromagnetic & Boltzmann’s turbine technologies might have a challenge.

 

Our Shenitech ultrasonic flow meters work on Transit time principle which ensures high accuracy. Our ultrasonic flow meters are used not only for domestic

water application but also in dirty water having high TDS, in Sewerage treatment & effluent treatment application.

 

Transit time principle is annotated as below.

 

“ It is the time difference taken by two UH frequency pulses to reach the diametrically opposite ends of the pipe, which is related to the velocity of the fluid media inside pipe in direct proportion ”

 

Suppose ‘T1’ is the time taken by pulse to travel downstream to the flow of media & ‘T2’ is the time take by the pulse to travel upstream of the flow media moving unidirectional with velocity ‘v’ , then time difference ‘δT’ is related to velocity as

 

(T2 – T1) = δT Or δT α v Or δT = k * v Or δT/k = v

 

Cross section area of pipe is ‘A’ Then Flow rate ‘Q’ can be calculated as

 Q=v*A 

 

We can offer inline type as well as clamp-on and insertion type sensors, depending upon the applications’ requirement. Our flow meters offer all standard signal outputs like analog outputs (4- 20 mA or 0-10 VDC), Modbus over RS-485, M-Bus etc. which is widely accepted for third party integration.

 

Benefits & Features :

  • Low maintenance as no moving parts
  • High Accuracy as high as ± 1%
  • OIML R49 standard. CE Approval
  • Low pressure drop
  • Tamper Proof Design
  • Low Cost Over long run

We have all types of sensors option available as far as mounting is considered. The sensor selection is generally depend upon the application & site conditions. We recommend to take our expert advice before making selection of appropriate sensor.


Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Inline Flow Meter?

Quantity
Seller Contact Details
  • Seller Ninth Wave Technologies
  • Address Sp Road, Secunderabad, Telangana

Find similar products

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
Electric Cast Iron Inline Flow Meter at Best Price in Secunderabad - ID: 5811027
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Electric Cast Iron Inline Flow Meter

Listing ID #5811027

  • MaterialCast Iron
  • Packaging TypePacked In Corrugated Boxes
  • Driven TypeElectric
  • Accuracy1.0% Of Reading At Rates > 0.5m/s 0.005 M/s Of Reading At Rates < 0.5m/s
  • Supply Type Exporter, Supplier
Preferred Buyer From : All over the world
View More Details
Send Enquiry

Company Information

  • Member Since 6 Years
  • Nature of Business Retailer
  • GST No. 36AAOFN3614M1ZV

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Material Cast Iron
  • Packaging Type Packed In Corrugated Boxes
  • Driven Type Electric
  • Accuracy 1.0% Of Reading At Rates > 0.5m/s 0.005 M/s Of Reading At Rates < 0.5m/s
  • Measuring Principle. Transit Time Difference
  • Connection Clamp
  • Warranty 1 Year

Details :

  • Excellent long-term stability
  • Best accuracy among the three transducer types
  • Flowmeter is pre-programmed in factory, thus, it is a simple plug and play device
  • For pipe size DN10~DN500 (3/8”~20”)

 

Ultrasonic flow measurement is among the best & most accurate technology available these days. It is widely accepted & prominently used across the industries due to its non-cohesive nature with the flow media. It is also non-effected in high magnetic field zones, where other technologies like electromagnetic & Boltzmann’s turbine technologies might have a challenge.

 

Our Shenitech ultrasonic flow meters work on Transit time principle which ensures high accuracy. Our ultrasonic flow meters are used not only for domestic

water application but also in dirty water having high TDS, in Sewerage treatment & effluent treatment application.

 

Transit time principle is annotated as below.

 

“ It is the time difference taken by two UH frequency pulses to reach the diametrically opposite ends of the pipe, which is related to the velocity of the fluid media inside pipe in direct proportion ”

 

Suppose ‘T1’ is the time taken by pulse to travel downstream to the flow of media & ‘T2’ is the time take by the pulse to travel upstream of the flow media moving unidirectional with velocity ‘v’ , then time difference ‘δT’ is related to velocity as

 

(T2 – T1) = δT Or δT α v Or δT = k * v Or δT/k = v

 

Cross section area of pipe is ‘A’ Then Flow rate ‘Q’ can be calculated as

 Q=v*A 

 

We can offer inline type as well as clamp-on and insertion type sensors, depending upon the applications’ requirement. Our flow meters offer all standard signal outputs like analog outputs (4- 20 mA or 0-10 VDC), Modbus over RS-485, M-Bus etc. which is widely accepted for third party integration.

 

Benefits & Features :

  • Low maintenance as no moving parts
  • High Accuracy as high as ± 1%
  • OIML R49 standard. CE Approval
  • Low pressure drop
  • Tamper Proof Design
  • Low Cost Over long run

We have all types of sensors option available as far as mounting is considered. The sensor selection is generally depend upon the application & site conditions. We recommend to take our expert advice before making selection of appropriate sensor.


Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Inline Flow Meter?

Quantity
Seller Contact Details
  • Seller Ninth Wave Technologies
  • Address Sp Road, Secunderabad, Telangana

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice