Contact SupplierRelying on our experience in the industry gained over years, we, as a Manufacturer, Supplier and Exporter of Defibrillator have positioned us in the top string of the industry. Our distribution network allows us to facilitate quick and convenient delivery in a matter of time at your doorstep. Its low maintenance, smooth operation and high performance make it an interesting proposition.
General | Power Supply | (AC Input) 100 to 230 V AC; ± 15 %; 50 / 60 Hz | - | - |
---|---|---|---|---|
Power Consumption | < 70 VA | - | - | |
Battery type | SLA 12V 4.5 Ah | - | - | |
Battery Capacity | More than 100 discharges of 300 Joules or 5 hours monitoring | - | - | |
Dimensions | 260 (W)x280 (D)x250 (H) mm | - | - | |
Weight | 10.5 kgs (with Printer, Battery & Paddle) | - | - | |
Environment | Operating Temperature : 0°C to 40°C Relative Humadity : 10 to 90 % RH(non condensing) |
- | - | |
Defibrillator | Technology | Current Controlled Bi-phasic | - | - |
Energy Stored (Max) | More than 300 Joules | - | - | |
Energy Select | - | - | - | |
-External | 2 to 300 J in steps 2,3,5,7,10,20,30,50,70,100,150,200,300 Joules | - | - | |
Charge Time |
< 10 secs to 300 J with battery(fully charged new battey) | - | - | |
Charge Indicator | Charge ready LED on the front panel and audible tone Charge ready LED on Apex Paddle |
- | - | |
Delivered Energy | Displayed on the screen | - | - | |
Synchronisation | DEFIBRILLATOR synchronized to the R wave Marker indication on the ECG waveform | - | - | |
Sync Message Display | Message on monitor screen and lamp on front panel | - | - | |
Paddles | Standard Adult Anterior Electrodes(84.5 cm²)Slide off to Expose Paediatric Electrodes(20 cm²) Retractable Cable Length:Coiled -600 mm, Stretched- 3000 mm. |
- | - | |
Monitor Section | Display | STN LCD 5" diagnol(120 mm x 90 mm)with CCFL backlight | - | - |
Display Resolution | 320 x 240 pixels | - | - | |
ECG Modes | Paddle ECG and Patient Cable ECG(1,2 and 3 standard leads) | - | - | |
Leads Off Message | On screen message with alert tones | - | - | |
CMRR | > 90dB @ 50Hz ;Input Impedance: > 2.5mΩ | - | - | |
Frequency Response | 0.5 to 35 Hz with filter | - | - | |
Sweep Speed | 25 mm/sec | - | - | |
Display Time | 4 secs | - | - | |
HR Display and Accuracy | 10 to 300 BPM; ±2 BPM(or) whichever is higher | - | - | |
HR Alarm | Audio Visual User Selectable Alarm Limits; 20 to 300 BPM insteps of 1 BPM |
- | - | |
1mV Cal Signal | Vertical Line(variable amplitude w.r.t. Gain) | - | - | |
ECG Out | 1V/1mV (depends on gain settings) | - | - | |
Patient Cable Length | 3 mts. | - | - | |
Electical Isolation and shielding | Input protected against high voltage DF Pulses and radio frequency interference |
- | - | |
Cautery filter | Built In | - | - | |
Printer Section | Recorder | 50 mm. | - | - |
Recording Type | Thermal Array Recording | - | - | |
Paper Size | 50 mm. X 20 mts.;Print width :40 mm | - | - | |
Paper Speed | 25 mm/sec | - | - | |
Print Mode | 6 sec delayed ECG | - | - | |
Event Recording | Stores and Prints upto 24 events Post Critical event data upto 24 events |
- | - | |
Print Annotations | Time,Date,Heart Rate,HR Limits,Event Marker,ECG Parameters,Defibrillator mode,Selected and Delivered Energy,Patient Impedance,Peak Current & Hospital Name | - | - | |
Standard Accessories | Defibrillator-Paddles(Adult & Paediatric) | 1 no. | Cardijelly | 1 no. |
Disposable Electrodes | 1 pkt | Patient Cable | 1 no. | |
Power Cord | 1 no. | Recording Paper(20 M roll) | 1 no. | |
Accessory Bag | 1 no. | User Manual | 1 no. |
Note : Due to constant upgradation, specifications & features subject to change without prior notice.
General | Power Supply | (AC Input) to 230 V AC; ± 15 %; 50 / 60 Hz | - | - |
---|---|---|---|---|
Power Consumption | 100 VA | - | - | |
Battery type | Rechargeable SMF Lead Acid | - | - | |
Battery Capacity | 12 v, 4.5 AH 7 hrs ony Monitoring; 100 Discharges of 360 joules | - | - | |
Dimentions | 260 (W)x280 (D)x250 (H) mm | - | - | |
Weight | 10.5 kgs (with Printer, Battery & Paddle) | - | - | |
Environment | Operating Temperature : 0°C to 40°C Relative Humadity : 10 to 90 % RH |
- | - | |
Defibrillator | Waveform | 5 sec Monophasic pulse(Lown) | - | - |
Energy Select | - | - | - | |
-External | 0 to 360 J in steps 2,3,5,7,10,20,30,50,70,100,150,200,300,360 | - | - | |
-Internal | 0 to 50 J in steps 2,3,5,7,10,20,30,50 | - | - | |
Charge Time | < 5 secs to 360 J with battery(fully charged new battery) <15 secs to 360 J without battery(AC mains only) |
- | - | |
Available and delivered energy | Displayed on the screen | - | - | |
Synchronisation | DEFIBRILLATOR synchronized to the R wave Marker indication on the ECG waveform | - | - | |
Sync Message Display | Message on monitor screen and lamp on front panel | - | - | |
Energy/HR Display | Displayed on the screen | - | - | |
Paddles | Standard Adult Anterior Electrodes(84.5 cm²)Slide off to Expose Paediatric Electrodes(20 cm²) Retractable Cable Length:Coiled -600 mm, Stretched- 3000 mm. |
- | - | |
Monitor Section | Display | Monochrome LCD 5" diagnol(120 mm x 90 mm)with CFL backlight | - | - |
Display Resolution | 320 x 240 pixels | - | - | |
ECG Modes | Paddle ECG and Patient Cable ECG(1,2 and 3 standard leads) | - | - | |
Leads Off Message | On screen message with alert tones | - | - | |
CMRR | > 90dB @ 50Hz ;Input Impedance: > 2.5mΩ | - | - | |
Frequency Response | 0.5 to 35 Hz with filter | - | - | |
Sweep Speed | 25 mm/sec | - | - | |
Display Time | 4 secs | - | - | |
HR Display and Accuracy | 30 to 250 BPM; ±2 BPM(or) whichever is higher | - | - | |
HR Alarm | Audio Visual User Selectable Alarm Limits; 30 to 300 BPM insteps of 5 BPM |
- | - | |
1mV Cal Signal | Vertical Line(variable amplitude w.r.t. Gain) | - | - | |
ECG Out | 1V/1mV (depends on gain settings) | - | - | |
Patient Cable Length | 3 mts. | - | - | |
Electical Isolation and shielding | Input protected against high voltage DF Pulses and radio frequency interference |
- | - | |
Cautery filter | Built In | - | - | |
Printer Section | Recording Type | Thermal Array Recording | - | - |
Paper Size | 50 mm. X 20 mts.;Print width :40 mm | - | - | |
Paper Speed | 25 mm/sec | - | - | |
Print Delay | 6 Secs. (Selectable in Auto Mode) | - | - | |
Event Recording | Stores and Prints 3 sec. Pre and 7 sec. Post Critical event data upto 24 events | - | - | |
Print Annotations | Time,Date,Heart Rate,HR Limits,Event Marker,ECG Parameters,Defibrillator mode,Selected and Delivered Energy,Patient Impedance,Peak Current & Hospital Name | - | - | |
Standard Accessories | Defibrillator-Paddles(Adult & Paediatric) | 1 no. | Cardijelly | 1 Bottle |
Disposable Electrodes | 30 nos. | Earth Cable | 1 no. | |
Patient Cable(3 lead) | 1 no. | Accessory Bag | 1 no. | |
Mains Cable(Power Cord) | 1 no. | User Manual | 1 no. | |
Internal Paddles | 1 no. | Recording Paper | 1 roll – 20 mtrs.(Applicable for DF 2509 R only) |
Note : Due to constant upgradation, specifications & features subject to change without prior notice.