    CERA BWP FLUSH DOOR

    • StandardIS:2202-(Part-1, 1999)
    • Thickness(MM)25, 30, 32, 35, 38, 40
    • Supply TypeManufacturer, Exporter, Supplier, Retailer, Trader
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 9 Years
    • building Nature of Business Retailer

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    Technical Specification
    Test Prescribed in IS:2202-(Part-1, 1999)Minimum Value for ConformityObserved Value
    General Fitness Test as per IS:4020 (Part 3), 1998Squareness measuredConfirmed
    Local Planeness Test as per IS:4020 (Part 4), 1998Planeness measured to ah accuracy of 0.1 mConfirmed
    Dimension and Squareness Test as per IS: 4020 (Part 2), 1998Height and Width measured within an accuracy of 1.0 mmConfirmed
    Impact indentation Test as per IS: 4020 (Part 5), 1998Indentation Measured to an accuracy of 0.1 mmConfirmed
    Edge Loading Test as per IS: 4020 (Part 7). 1998The deflection measured to an accuracy of 0.1 mmConfirmed
    Flexure Test as per IS: 4020 (Part 6), 1998The deflection measured to an accuracy of 0.1 mmConfirmed
    Slamming Test as per IS: 4020 (Part 10), 199850 times on the nail at the rate of 4-5 dropl minConfirmed
    Buckling Test as per IS: 4020 (Part 9). 1998Deformation measured to an accuracy of 1mm, 5 min. after application of the load and 15 min. after unloadingConfirmed
    Shock Resistance Test as per IS: 4020 (Part 8), 19984 to 5 shocks minimumConfirmed
    Misuse Test as per IS: 4020 (Part 11), 1998Should pass after applying 2OON force to the handle at right anglesConfirmed
    End Immersion Test as per IS:4020 (Part 13), 1998No-delaminationNo-delamination found
    Varying Humidity Test as per IS: 4020 (Part 12), 1998‘Deviation measures to an accuracy of 1 .0 mmConfirmed
    Knief Test as per IS: 4020 (Part 14) 1998Minimum Pass StandardExcellent Standard
    Screw Withdraw as per IS: 4020 (Part 16), 1998Applied load should be 2.0 mm per min for complete withdrawal of the screwConfirmed
    Glue Adhesive Test as per IS: 4020 (Part 15), 1998There shall be no-delaminationNo-delamination found
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for CERA BWP FLUSH DOOR?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice