Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    Class Multifunction Power and Energy Meter

    • Supply TypeManufacturer, Exporter, Supplier
    • Preferred Buyer Location All over the world

    Application Sub-station Metering Industrial Large Feeder Metering Load profile analysis. Sub-Metering Power generation Power Quality analysis. Comprehensive and Accurate Measurement 3-phase....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 16 Years
    • building Nature of Business Manufacturer

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    Application
    • Sub-station Metering
    • Industrial Large Feeder Metering
    • Load profile analysis.
    • Sub-Metering
    • Power generation
    • Power Quality analysis.
    Comprehensive and Accurate Measurement
    • 3-phase Voltage (L-N)
    • 3-phase Voltage (L-L)
    • 3-phase Current
    • KW (3-phase and Total)
    • KVAR (3-phase and Total)
    • KVA (3-phase and Total)
    • PF (3-phase and Total)
    • Bidirectional KWh
    • KVAh
    • KVARh
    • Frequency
    • % THD
    • Demand & MD
    Relay Outputs Options

    The SLM102 has four relay outputs, related at 3A. These can be used for alarm/trip events. The use of these relays is totally field configurable, for the parameter on which to operate, the value on which to trip, the delay offer which to trip and the value at which to open. This enables the SLM102 to be used as a maximum demand controller.

    Communication

    Ethernet
    The SLM102 has a standard Ethernet-TCP/IP connection. Multiple socket Ethernet connectivity enables the unit to respond to as many as 12 different requests. The SLM102 can act as a small web-server.This on-board web-sever, offers quick and easy access to basic measurement, without special software. Built-in web pages display a range of power, energy and basic power quality information through any web enabled device. It also supports MODBUS-TCP/IP protocol.

    Features
    • Exceeds class 0.2 revenue accuracy in Power & Energy Metering.
    • On board Ethernet port supporting TCT/IP protocol. Acts as a small web-server. Also supports MODBUS TCP/IP.
    • RS485 port with MODBUS-RTU protocol.
    • Demand Measurement: Fixed or sliding. KW or KVA.
    • Harmonics measurement: All six waveforms upto 29th including THD.
    • Bright Red LED display. Three rows of 8-digits each ensure unbroken display of even large energy register values.
    • Four relay outputs for Alarm & Trip. Limits are field programmable.
    • Event definition and logging.
    • Datalogging of all parameters for load pattern analysis. 2 Mbytes memory on-board.
    • USB 2.0 port to download logged data.
    • USB 2.0 port based programming of field selectable parameters.
    Advance Measurement Features

    SLM102 also measures the minimum & maximum values and also allows definition of events, so that the user can define the parameter of interest, event definition value and related time delays.

    • Voltage min/max. -3-phsae L-N
    • Voltage min/max. - 3-phase L-L (applicable only for 3P3W)
    • Current min/max. - 3-phase.
    • Hz min/max.
    • Active Power min/max. - 3-phase & Σ system
    • Apparent Power min/max. - 3-phase & Σ system
    Harmonic Measurement

    SLM102 measures the odd harmonics for 3Ø voltages and 3Ø currents upto 29th, includidng THDs for each waveform.

    Data Logging

    The SLM102 has 2Mb on-board non-volatile memory. The unit has a user programmable log capacity, that is the log duration is site selectable. A complete electrical system snap-shot is saved, to be later downloaded using the USB 2.0 port, into a PC based utility supplied free by Trinity.



    Parameters
    Type Name Statistics Symbol 3P4W 3P3W
    True RMS Basic param etersVoltage(Volts L-N)Direct Voltage Input : 0 to 300 VAC
    PT Ratio : Programmable upto 66 KV
    Range of Reading : 0 to 66 KV
    Accuracy : 0.2% of reading : (50
    VrY-
    Vy-
    VbY-
    Voltage(Volts L-L)Direct Voltage Input : 0 to 450 VAC
    PT Ratio : Programmable upto 66 K
    Range of Reading : 0 to 66 KV
    Accuracy : 0.5% of reading : (85
    Vry
    Vbr-
    Vyb
    Current(Ir, Iy, Ib)Secondary Current input : 1A or 5A
    CT Ratio : Freely programmable from
    5A to 5000ARange of Reading : 0 to 5000A
    Accuracy : 0.2% of reading (0.02 IB
    Ir
    Iy-
    Ib
    Line(Frequency)45 to 55 HZ
    Accuracy : 0.5% of Reading
    Hz
    PowerActivePower(P)Accuracy : See Table-1(0.5 < cosθ < 0.8)(P) R-Phase
    (P) Y-Phase-
    (P) B-Phase
    ReactivePower(Q)Accuracy : See Table-1(0.5 < sinθ <0.8)(Q) R-Phase
    (Q) Y-Phase-
    (Q) B-Phase
    ApparentPower(S)Accuracy : 0.3% of Reading(0.01 Ib ≤ I < Imax)(S) R-Phase-
    (S) Y-Phase-
    (S) B-Phase-
    System ActivePower(P)Accuracy : See Table-1(0.5 < cosθ < 0.8)Σ-P
    System ReactivePower(Q)Accuracy : See Table-1(0.5 < sinθ <0.8)Σ-P
    System ApparentPower(S)Accuracy : 0.3% of Reading(0.01 Ib ≤ I < Imax)Σ-P
    Power Factor0.5% for 0.5 < |PF| < 0.8,(0.05 Ib < I < 1.2 Ib)PF R-Phase-
    PF Y-Phase-
    PF B-Phase-
    System PF
    Table 1-Percentage Error Limits for Power
    Value fo Current PF Percentage Error Limits
    0.01 Ib ≤ I < 0.05 Ib1.0±0.4
    0.05 Ib ≤ I ≤ Imax1.0±0.2
    0.02 Ib ≤ I < 0.1 Ib0.5 Lagging±0.5
    0.8 Leading±0.5
    0.01 Ib ≤ I ≤ Imax0.5 Lagging±0.3
    0.8 Lagging±0.3
    Energy, Demand and Power Quality
    Parameters Mode
    Type Statistics 3P4W 3P3W
    Total ActiveEnergy(KWh)Range of reading : 0 to 9999999.9 MWh
    Accuracy : 0.2S as per IS 14697:1999
    Total ReactiveEnergy(KVARh)Range of reading : 0 to 9999999.9 MVARh
    Accuracy : 0.2S as per IS 14697:1999
    Total ApparentEnergy(KVAh)Range of reading : 0 to 9999999.9 MVAh
    Active PowerDemand(KWDMND)Sliding and Fixed selectable
    Apparent PowerDemand(KVADMND)Sliding and Fixed selectable
    Harmonics for Voltages (3rd to 29th)
    Harmonics for Current (3rd to 29th)
    THD for each voltage
    THD for each current
    Power Supply:

    Self Power. Unit has in-built 3-phase supply with an operating range of 50 VAC - 480 VAC, 50-60 Hz.

    Miscellaneous
    Display 8X3 (Digits X Lines) 7 Segment LED display
    Eighteen LEDs for parameter indication
    Two LEDs for Active and Reactive Energy (1000 impulse / KWh or KVARh).
    Dimensions Bezel : 144 mm X 144 mm.
    Depth of Installation : 55 mm
    Panel cutout : 138 mm X 138 mm
    Operating Temperature : 0°C to 60°C
















    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Class Multifunction Power and Energy Meter?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice