Contact SupplierOur company offers refrigerated type Compressed Air Receiver 20 - 1500 CFM. It comes with the following components :
Our refrigerated type Compressed Air Receiver uses pre-cooling methodology so that a smaller refrigeration unit can do the job (more economical). The heat exchanger used in this product has no extended surfaces or sharp corners that collect dust, dirt or oil residue, this is by design to ensure that all and any dust, dirt and oil is washed from the air.
Our company is based out of Delhi, we supply a wide range of products which include: industrial blowers, compressors, vacuum pumps etc.
Model | Capacity (SCFM) |
Inlet Press Kg/cm² |
Max Working Press Kg/cm² |
Inlet Temp deg C |
Volt. Supply |
Power Cons (kW) |
Ref Gas |
Noise Level (dBA) |
Weight (Kg) |
End Conn |
---|---|---|---|---|---|---|---|---|---|---|
GD20 | 20 | 7 | 16 | 45 | 230/50/1 | 0.32 | R134a | 69 | 38 | 3/4" BSP F |
GD40 | 40 | 7 | 16 | 45 | 230/50/1 | 0.34 | R134a | 69 | 55 | 1" BSP F |
GD50 | 50 | 7 | 16 | 45 | 230/50/1 | 0.34 | R134a | 69 | 55 | 1" BSP F |
GD60 | 60 | 7 | 16 | 45 | 230/50/1 | 0.34 | R134a | 69 | 55 | 1" BSP F |
GD80 | 80 | 7 | 16 | 45 | 230/50/1 | 0.85 | R134a | 69 | 70 | 1" BSP F |
GD100 | 100 | 7 | 16 | 45 | 230/50/1 | 0.85 | R134a | 69 | 70 | 1" BSP F |
GD150 | 150 | 7 | 16 | 45 | 230/50/1 | 1.02 | R134a | 69 | 110 | 1.5" BSP F |
GD200 | 200 | 7 | 16 | 45 | 230/50/1 | 1.75 | R407C | 69 | 100 | 2" NB |
GD250 | 250 | 7 | 16 | 45 | 230/50/1 | 1.75 | R407C | 69 | 100 | 1.5" BSP F |
GD300 | 300 | 7 | 16 | 45 | 230/50/1 | 2.3 | R407C | 69 | 200 | 2" NB |
GD400 | 400 | 7 | 16 | 45 | 415/50/3 | 2.3 | R407C | 69 | 260 | 2" NB |
GD500 | 500 | 7 | 16 | 45 | 415/50/3 | 2.3 | R407C | 69 | 290 | 2" NB |
GD650 | 650 | 7 | 16 | 45 | 415/50/3 | 3.34 | R407C | 69 | 350 | 2" NB |
GD800 | 800 | 7 | 16 | 45 | 415/50/3 | 4.8 | R407C | 69 | 540 | 3" NB |
GD1000 | 1000 | 7 | 16 | 45 | 415/50/3 | 4.8 | R407C | 69 | 580 | 3" NB |
GD1250 | 1250 | 7 | 16 | 45 | 415/50/3 | 5.63 | R407C | 69 | 620 | 4" NB |
GD1500 | 1500 | 7 | 12 | 45 | 415/50/3 | 7.15 | R407C | 69 | 900 | 4" NB |
Requirement : | Inlet flow | 100 cfm |
---|---|---|
Working pressure | 5 Kg / cm² | |
Inlet temperature | 45° C | |
Ambient temperature | 38° C | |
Referring tables : | Factor Pi | 0.84 |
Factor Ti | 1 | |
Factor Ta | 1 | |
Dryer capacity required : |
Flow Pi x Ti x Ta |
100 0.84 x 1 x 1 |
119 cfm |
Inlet Air Temperature °C | 30 | 38 | 45 | 50 |
---|---|---|---|---|
Correction Factor (Ti) | 1.14 | 1.08 | 1 | 0.75 |
Inlet Pressure Kg/cm² | 2 | 5 | 9 | 12 |
Factor (Pi) | 0.84 | 1 | 1.11 | 1.21 |
Ambient Temperature °C | 25 | 30 | 38 | 43 |
Factor (Ta) | 1.36 | 1.18 | 1 | 0.86 |