Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    CT-2 Electrical Contact Cleaning Spray, Form : Liquid

    • FormLiquid
    • Pack Quantity300 ml
    • Can ColorBlack
    • Packing MaterialPacked in Metal Cans
    • Supply TypeManufacturer, Supplier, Retailer
    • Preferred Buyer Location All over the world

    Features Useful to remove contaminants that could provide a path for tracking or arcing and to remove grime that may be insulating and cause overheating Grease, oil, lubricants, carbon etc can be....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 10 Years
    • building Nature of Business Retailer
    • gst icon GST No. 27AADPS4961K1Z7

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details

    Product Details no_img_icon

    Features

    • Useful to remove contaminants that could provide a path for tracking or arcing and to remove grime that may be insulating and cause overheating
    • Grease, oil, lubricants, carbon etc can be removed from contacts
    • As opposed to many so called cleaners, it contains no oil based products that affect the sensitive contact mating mechanism and reduce the life of the equipment
    • It evaporates within 20 seconds, making the joint ready for casting
    • It is easy to use aerosol is especially useful in ducts and man holes, where there is limited space


    Directions for use

    • Shake can thoroughly
    • Apply even coat
    • For hard to reach or small areas attach snorkel tube to actuator tip
    • Stabilizes Connections Between Similar & Dissimilar Metals


    Electrical contacts play a crucial role in electrical circuits, as they make and break the flow of currents in circuits. An ideal electrical contact offers infinite resistance when open and zero resistance when closed. In actuality, the contact does have a finite resistance when closed; this resistance has a heating effect due to so-called'I-squared-R' losses. If not maintained properly, the contacts will offer high resistance and may evenburn up due to overheating.
    Referring to the diagram, it can be seen that a 440V ac circuit has more than 1200 volts peak-to-peak appearing across the contact, which becomes a spark gap as the contact closes or opens. As a result, the foreign material present m me surrounding air gets deposited on me contact surface, thus creating an insulating layer, and increasing the contact resistance.
    What are Electrical Contact Cleaners ?
    Electrical cleaners are used to remove contaminants that could provide a path for tracking or arcing, and to remove grime that would cause overheating. These cleaners can also be used to advantage to clean stripped wires before joining terminals and so forth.
    Constituents of High Quality Contact Cleaner Aerosols
    Aerosols are a convenient means of providing cleaning action, on even hard to reach contacts. The 'Ingredients include an- appropriate chemical compound and a propellant. Many different kinds of compounds and propellants can be used. What is -Important, however, is that the compounds must not be oil-based, because such compounds will aggravate the dirt on the contact surface.
    Can Contract Cleaner Be Applied On Live Contacts ?
    It is important to understand the functioning of the aerosol cleaners; these do not by themselves do anything more than loosen the dirt and grime; it is the wiping action of the contact which ultimately removes such contaminants; just as one needs to scrub and not just apply soap for washing one's hands. So, simply spraying a cleaner on a live contact is not an advisable method of suing contact cleaner, not to mention the fact that this is a hazardous practice not approved under electrical codes or the Factory Act. and may invalidate any future insurance claims. The following table illustrate the advantages of our contact cleaner over some competitive brands


    Details

     kli-nitBrand ABrand B
    Whether it is Environmentally Friendly (Ozone Friendly)YesNoYes
    Oil BaseNoYesYes
    Recommended for Live CircuitsNoNoYes
    Whether approved by Electricity authoritiesYesNANA
    Whether approved by Defense authoritiesYesNANA
    PropertySpecificationTest methodUnit
    AppearanceColourless liquidVisual--
    DensityAbout 1.0 (of base)In-houseg/cc
    Shelf life3In-houseYears
    CFCDoes not containIn-house--
    Solid contain0.015%In-house--
    Drying time10-15 secondsIn-houseSeconds

    Applications


    Download Detail File : Click Here

    Download Brochure


    Download Detail File : Click Here

    Download Material Safety Data Sheet


    Download Detail File : Click Here
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for CT-2 Electrical Contact Cleaning Spray?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice