| Function | Range | Accuracy | Resolution | Remarks | ||||
| ACV | 400mV | 1.2% of rdg | 0.1mV | Overload protection: 1000V DC/750Vrms ACImpedance: 10MΩ,More than 100MΩ on 400mV scale | ||||
| 4V | 0.8% of rdg | 1mV | ||||||
| 40V | 10mV | |||||||
| 400V | 100mV | |||||||
| 1000V | 1.5% of rdg | 1V | ||||||
| DCV | Range | Accuracy | Resolution | Frequency | Average sensing, calibrated to rms of sine waveOverload protection: 1000V DC/750Vrms AC
Impedance: 10MΩ. | |||
| 400mV | ±2.5% of rdg | 0.1mV | 50~100Hz | |||||
| 4V | 1.2% of rdg | 1mV | ||||||
| 40V | 10mV | |||||||
| 400V | 100mV | |||||||
| 750V | 2.5% of rdg | 1V | ||||||
| ACA | Range | Accuracy | Resolution | Overload protection: 1000Arms within 60 seconds | ||||
| 4000mA | 3.5% of rdg | 1mA | ||||||
| 30A | 3.0% of rdg | 10m A | ||||||
| DCA | Range | Accuracy | Resolution | Frequency | Average sensing, calibrated to rms of sine waveOverload protection: 1000Arms within 60 seconds | |||
| 4000mA | 3.5% of rdg | 1mA | 50~60Hz | |||||
| 30A | 3.0% of rdg | 10m A | ||||||
| Resistance | Range | Accuracy | Resolution | Overload protection: 250V DC/250Vrms AC | ||||
| 400Ω | 1.8% of rdg | 0.1Ω | ||||||
| 4kΩ | 1.2% of rdg | 1Ω | ||||||
| 40kΩ | 10Ω | |||||||
| 400kΩ | 100Ω | |||||||
| 4MΩ | 1kΩ | |||||||
| 40MΩ | 2.0% of rdg | 10kΩ | ||||||
| Capacitance | Range | Accuracy | Resolution | Overload protection: 250V DC/250Vrms AC | ||||
| 40nF | 3.5% of rdg | 10PF | ||||||
| 400nF | 2.5% of rdg | 100PF | ||||||
| 4μF | 1nF | |||||||
| 40μF | 10nF | |||||||
| 100μF | 3.5% of rdg | 100nF | ||||||
| Frequency | Range | Accuracy | Resolution | Sensitivity | Overload protection: 250V DC/250Vrms ACDuty cycle: 0.1%~99.9% | |||
| 10Hz | 0.5% of rdg | 0.01Hz | Range of input voltage:1.5V~10V, If input voltage over range, need adjust | |||||
| 100Hz | 0.1Hz | |||||||
| 1000Hz | 1Hz | |||||||
| 10kHz | 10Hz | |||||||
| Temperature(NiCr-NiSi sensor) | Range | Accuracy | Resolution | Overload protection: 250V DC/250Vrms AC | ||||
| ℃ | -20~150℃ | 3℃+2 | <400℃ | 1℃ | ||||
| 150~300℃ | 3.0% of rdg | <400℃ | 1℃ | |||||
| 300~1000℃ | 3.5% of rdg | ≥400℃ | 1℃ | |||||
| Diode and Audible continuity test | Range | Description | Test condition | Overload protection: 250V DC/250Vrms AC | ||||
| Display read approx.Forward voltage of diode. | Forward DC currentapprox. 0.4mA
Reversed DC voltage approx. 1.5V | |||||||
| Built-in buzzer soundsif resistance is less
than 70Ω | Open circuit voltageaprox. 0.5V | |||||||