Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Distribution Transformer

Listing ID #126452

  • Supply Type Manufacturer, Supplier
Preferred Buyer From : All over the world

We manufacture and supply premium quality Distribution Transformer which are praised by our clients for their high operational output and international deisgn. Our Distribution Transformer which....
View More Details
Send Enquiry

Company Information

  • Member Since 15 Years
  • Nature of Business Retailer
  • Year of Establishment 1997

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

We manufacture and supply premium quality Distribution Transformer which are praised by our clients for their high operational output and international deisgn. Our Distribution Transformer which complies to IS: 1180/Part-II and IS: 2026 are widely used by our clients for :-
Measurement of winding resistanceMeasurement of voltage ratioMeasurement of impedance voltage/short circuit impedance & load loss at 75’CMeasurement of No-load loss and No-load currentMeasurement of insulation resistanceInducted over voltage withstand testSeparate source voltage withstand test
Main Components :-
Core :-
The magnetic core is built up from Prime high quality CRGO generally M4 Grade. MOH, M1H, HIB Grade. Laminations are coated with oil and heat resistant insulation. Laminations are free from Burs. The construction is only through interleaved mitred joints to have uniform Flux density, minimum excitation power and minimum core loss. All core-cutting facilities are available with us. We are directly importing Prime core to ensure quality
Oil :-
Dehydrated mineral oil as per IS : 335 (1993) with latest amendments is used for proper insulation and cooling. ARDISONS ASSOCIATES has in-house facilities to test the oil for resistivity, tan delta, B.D.V. neutralization, flash point etc. to ensure the ageing characteristics
Coil
Mainly Aluminium Conductors are used for 25kVA to 200 kVA and electrolytic grade copper conductors are used for lower ratings upto 20kVA & higher ratings above 200 kVA. Type of coils helical, continuous disc, cross over coils depends on voltage class and transformer ratings as designed by our designing department. Electrical grade Kraft paper, press board as per IS : 1576 and permawood are used as solid insulating materials. Sufficient cooling ducts are provided to reduce the temperature rise of winding, oil and hot spot. All coils are preshrunk as per the seasoning cycle to withstand mechanical forces developed during short time overloads and short circuit conditions
Tanks :-
The interior surface of the tank is cleaned by chemical/ shot or sand blasting and coated with oil resistant zinc chromate primer. Conservator, meter boxes, rollers, conventional /sealed type tank are provided as per the rating / requirement. All tanks are tested on pressure as well as under vacuum to ensure zero leakage & requisite amount of deflection. To meet the variation of pressure inside the tank, due to variation in temperature and short circuit current, the tanks are suitably stiffened. ARDISONS has got the full fledged In House.
Fittings :-
Gas operated relay, MOG, Oil Temperature Indicator, Winding Temperature Indicator. Marshalling box, tap switch either off circuit or OLTC are provided as per the rating / requirement
Testing :-
The transformers is tested at our works with modern , sophisticated, computerized , regularly calibrated Power Analyzer & meters through a centralized control panel. Dynamic short circuit and impulse voltage test can be conducted at any Government agency if required, and temperature rise test can be conducted at our works. All of our designs are type tested for lightning Impulse Voltage and Short Circuit withstand tests (Dynamic and Thermal).All the transformers are subjected to the following below mentioned routine tests at the works. The following routine tests are carried out in accordance with the details specified in the latest version of
IS: 1180/Part-II and IS: 2026
Measurement of winding resistance Measurement of voltage ratioMeasurement of impedance voltage/short circuit impedance & load loss at 75’C Measurement of No-load loss and No-load currentMeasurement of insulation resistance.
Inducted over voltage withstand testSeparate source voltage withstand test.


Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for distribution transformer?

Quantity
Seller Contact Details
  • Seller Ardisons Associates
  • Address Phase 8, Mohali, Punjab

Find similar products

View all products in Transformers
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice

Distribution Transformer

Listing ID #126452

  • Supply Type Manufacturer, Supplier
Preferred Buyer From : All over the world

We manufacture and supply premium quality Distribution Transformer which are praised by our clients for their high operational output and international deisgn. Our Distribution Transformer which....
View More Details
Send Enquiry

Company Information

  • Member Since 15 Years
  • Nature of Business Retailer
  • Year of Establishment 1997

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

We manufacture and supply premium quality Distribution Transformer which are praised by our clients for their high operational output and international deisgn. Our Distribution Transformer which complies to IS: 1180/Part-II and IS: 2026 are widely used by our clients for :-
Measurement of winding resistanceMeasurement of voltage ratioMeasurement of impedance voltage/short circuit impedance & load loss at 75’CMeasurement of No-load loss and No-load currentMeasurement of insulation resistanceInducted over voltage withstand testSeparate source voltage withstand test
Main Components :-
Core :-
The magnetic core is built up from Prime high quality CRGO generally M4 Grade. MOH, M1H, HIB Grade. Laminations are coated with oil and heat resistant insulation. Laminations are free from Burs. The construction is only through interleaved mitred joints to have uniform Flux density, minimum excitation power and minimum core loss. All core-cutting facilities are available with us. We are directly importing Prime core to ensure quality
Oil :-
Dehydrated mineral oil as per IS : 335 (1993) with latest amendments is used for proper insulation and cooling. ARDISONS ASSOCIATES has in-house facilities to test the oil for resistivity, tan delta, B.D.V. neutralization, flash point etc. to ensure the ageing characteristics
Coil
Mainly Aluminium Conductors are used for 25kVA to 200 kVA and electrolytic grade copper conductors are used for lower ratings upto 20kVA & higher ratings above 200 kVA. Type of coils helical, continuous disc, cross over coils depends on voltage class and transformer ratings as designed by our designing department. Electrical grade Kraft paper, press board as per IS : 1576 and permawood are used as solid insulating materials. Sufficient cooling ducts are provided to reduce the temperature rise of winding, oil and hot spot. All coils are preshrunk as per the seasoning cycle to withstand mechanical forces developed during short time overloads and short circuit conditions
Tanks :-
The interior surface of the tank is cleaned by chemical/ shot or sand blasting and coated with oil resistant zinc chromate primer. Conservator, meter boxes, rollers, conventional /sealed type tank are provided as per the rating / requirement. All tanks are tested on pressure as well as under vacuum to ensure zero leakage & requisite amount of deflection. To meet the variation of pressure inside the tank, due to variation in temperature and short circuit current, the tanks are suitably stiffened. ARDISONS has got the full fledged In House.
Fittings :-
Gas operated relay, MOG, Oil Temperature Indicator, Winding Temperature Indicator. Marshalling box, tap switch either off circuit or OLTC are provided as per the rating / requirement
Testing :-
The transformers is tested at our works with modern , sophisticated, computerized , regularly calibrated Power Analyzer & meters through a centralized control panel. Dynamic short circuit and impulse voltage test can be conducted at any Government agency if required, and temperature rise test can be conducted at our works. All of our designs are type tested for lightning Impulse Voltage and Short Circuit withstand tests (Dynamic and Thermal).All the transformers are subjected to the following below mentioned routine tests at the works. The following routine tests are carried out in accordance with the details specified in the latest version of
IS: 1180/Part-II and IS: 2026
Measurement of winding resistance Measurement of voltage ratioMeasurement of impedance voltage/short circuit impedance & load loss at 75’C Measurement of No-load loss and No-load currentMeasurement of insulation resistance.
Inducted over voltage withstand testSeparate source voltage withstand test.


Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for distribution transformer?

Quantity
Seller Contact Details
  • Seller Ardisons Associates
  • Address Phase 8, Mohali, Punjab

Browse Related Categories

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice