    Dual Channel Dust Sampler, Feature : Durable, Fine Finished

    • FeatureDurable, Fine Finished
    • PM 2.5 Size SeparatorSeparate set of inlet assembly with EPA PM 2.5 WINS Impactor
    • Bar Press SensorRange 600 to 800 mm Hg. Resolution, 1 mm Hg
    • ModelIPM-FDS 2510
    • Supply TypeManufacturer, Exporter, Supplier, Retailer, Distributor, Importer, Trader
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 17 Years
    • building Nature of Business Retailer
    • gst icon GST No. 27AFNPK8304B1ZL

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • FeatureDurable, Fine Finished
    • Bar Press SensorRange 600 to 800 mm Hg. Resolution, 1 mm Hg
    • Leak TestInternal & External Leak check feature for accurate sampling.
    • Dust Instruments MeasurementPm2.5 & Pm10
    • ModelIPM-FDS 2510
    • PM 2.5 Size SeparatorSeparate set of inlet assembly with EPA PM 2.5 WINS Impactor

    When it comes to innovation in Ambient Air Sampling technology, Instrumex has delivered yet again! The most common hassle faced by Consultants in order to comply with the CPCB norms for Ambient Air Sampling - was using two separate instruments for measurement of PM2.5 & PM10 Dust. Instrumex has found the solution to this problem - The Dual Channel Sampler for measurement of PM2.5 & PM10 dust concentrations in ambient air – Simultaneously!

     

    The flow control module uses the proven technology used in Instrumex's IPM-FDS 2.5/10µ Fine dust Sampler that has enjoyed over 400 installations across India and abroad. The two channels in IPM-FDS-2510 are individually controlled by separate flow control element but integrated into a single controller module. Thereby giving precise microprocessor based flow control for two channels. Both the channels individually comply with Federal Reference Method of USEPA as described in 40 CFR Part-50 Appendix L for determination of Particulate Matter. It also confirms with the CPCB guidelines for Measurement of Ambient Air Pollutants.

     

    Features

    • Dual channel enables measurement of PM-10 & PM10 Simultaneously
    • PM-10 Confirms to 40 CFR, Part 50 Appendix J of USEPA
    • PM-2.5 Confirms to 40 CFR, Part 50 Appendix L of USEPA
    • Microprocessor based Precision flow control for each channel
    • Data Logging of all parameters for each channel
    • Data Retrieval by USB and RS-232 ports
    • Extremely portable with Foldable tripod stands and carry case


    Specification

    PM 2.5 Size SeparatorSeparate set of inlet assembly with EPA PM 2.5 WINS Impactor
    PM 10 Size SeparatorEPA Omni-directional ambient particle inlet with 10µ separation assembly & sample transport tube.
    Flow Rate Meter & Volume Totaliser (USEPA Procedure Followed)Flow in LPM on Digital Display for both the channels with a Resolution of 0.01 LPM under actual operating conditions. Flow rate maintained Constant @ 16.67 LPM with ±2% Accuracy Throughout Sampling Period using Microprocessor Based Digital Flow Controller.
    Clock / Timer SystemProgrammable Real Time control system with automatic start & stop & digital display of date & time & time of sampling. Accuracy ± 2 min / month.
    Temperature SensorsFor Ambient temperature & Two Filter temperatures for PM2.5 and PM10 each. Range - 5°C to 50°C with a Resolution of 0.10C.
    Bar Press SensorRange 600 to 800 mm Hg. Resolution, 1 mm Hg
    Leak TestInternal & External Leak check feature for accurate sampling.

    Microprocessor Based Digital Flow Controller

    Sample Flow Rate Flow in LPM on digital display for both the channels with a Resolution of 0.01 LPM under actual operating conditions. Flow rate maintained at 16.67LPM (1m3/hr) ±5%, Accuracy ± 2% of reading throughout the sampling period. Calibrated from FCRI, Palakkad.
    Volume TotaliserVolume Totalized from flow rate & available on display with a resolution of 0.01m3
    Interval Data5 Minute averages of Ambient Temperature, Filter Temperature, Barometric Pressure, Real time Flow and Volumetric Flow Rate.
    User InterfaceA Simple menu driven interface & soft function keys for easy operation even by unskilled personnel.
    Flow Rate ComputationFlow is recorded as Average flow rate, Total Volume Sampled and Percentage Coefficient of Variation.
    Display

    Switchable Display to select parameter for Channel – 1 or Channel – 2 20x4 LCD display showing parameters in real time.

     
    Flow Rate (16.67) LPM
    Volumetric Flow
    Barometric Pressure
    Ambient Temperature
    Filter Temperature
    Warning Flag IndicatorWarning Flag Indicators for certain conditions going out of specification
    Data Transfer OptionConvenient in-field data transfer on a USB drive by an optional USB Interface. Enables user to generate reports even while sampling at remote locations. Default option is RS-232 serial port.

    Details


    Download Detail File : Click Here
    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Dual Channel Dust Sampler?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice