    Lubcon Engineers are typically used in applications where a large number of lubrication points need to be lubricated from a single source.   Each central lubricating unit is connected to their....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 15 Years
    • building Nature of Business Retailer

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details

    Product Details no_img_icon

    Lubcon Engineers are typically used in applications where a large number of lubrication points need to be lubricated from a single source.

     

    Each central lubricating unit is connected to their distributors through two lines via the change over valves. The two (2) lines alternatively act as supply pressure line and return line connected to container.

    When the central lubricating pump unit is operated, lubricant is delivered through the main lines of the system. The pump unit will continue to deliver lubricant and the pressure will continue to rise in the main line until the lubricant flow resistance at the lubrication point are overcome. At this point, the control valve and operating pistons within the individual metering distributors are actuated and a measured quantity of grease as determined by the diameter and length of stroke of the operating piston is delivered to the bearings.
     
    When all the metering distributors have discharged their respective quantities of lubricant, further pumping raises the line pressure. As soon as the line pressure exceeds the setting of pressure control valve, the change over valve operates to switch relieved to the grease container and the other line which was under relief is connected to the pump outlet so that next cycle of lubrication can start.
     
    The line pressure is sensed at the pump end and the pressure in the pressure control valve is set to a sufficiently high value in order to ensure operation of all the meter distributors. Both lines are blocked at the ends.
    There is a provision of visual indicator pins to the change over valve which is co-operation with a limit switch relays electric signal to the control system which deenergises the pump motor and activates the time relay which determines the interval time between two successive pumpings.
     
    After the pre-set time (0-2 hours) of the internal time relay is over, the pump re-stars and completes the next pumping cycle. The pumping repeats itself in the above manner and the lubrication of all points connected to the system continues.


    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Dual Line Lubrication System?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice