    Dual Tube Flowmeter With AHD

    • N2o Tube Range0.1– 12 L/min, with Expanded Scale At 0.1 – 1 L/min Graduations in Lpm Unit
    • Markings/identificationFloat Mark On Tubes & other Markings as per Iso 5358
    • Accuracy (o2& N2o)As per Iso-5358
    • N2o CutoffBuilt-in Fitted At Back
    • Supply TypeManufacturer, Exporter, Supplier
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 20 Years
    • building Nature of Business Manufacturer
    • gst icon GST No. 19AACCC2453J1ZN

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • Oxygen Tube Range0.1 – 10 L/min, with Expanded Scale At 0.1 – 1 L/min Graduations in Lpm Unit
    • Mixed Gas Outlet6 Mm Festo Connection from Rear Top ,(straight)
    • MountingBack Bar Mounting, as per Drawing
    • Metering TubeBorosilicate Glass.
    • N2o CutoffBuilt-in Fitted At Back
    • N2o Inlet6 Mm Festo Connection from Rear Bottom ,(straight)
    • HousingAluminum Frame, Acrylic Front, Background On White Acrylic Sheet.
    • N2o Tube Range0.1– 12 L/min, with Expanded Scale At 0.1 – 1 L/min Graduations in Lpm Unit
    • Tube Length (o2& N2o)220 Mm
    • Control Knob N2oAluminium Serrated, Serration Depth <1mm, Knob Dia Lower Than Oxygen Knob Dia
    • Markings/identificationFloat Mark On Tubes & other Markings as per Iso 5358
    • Tube Fitting ArrangementLeft-n2o, Right –o2
    • Working Pressure (max)420 Kpa (both N2o & O2)
    • Control Knob OxygenAluminium with Special Profile as per Iso 5358
    • Accuracy (o2& N2o)As per Iso-5358
    • Compliance ToIso-5358, Rohs
    • FloatAluminium-is-6063,Anodised Red –for O2& N2o
    • Material of ConstructionBrass-is-319 Natural Colour/aluminium Is-6063 Anodized Natural, O Rings & Washer Epdm.
    • Oxygen / N2o Ratio30 + 5% of O2 At all Settings After N2o Flow Opening.
    • Labels for Control Knob-o2/n2oO2-black On White Back Ground/n2o-white On Blue Back Ground
    • Hypoxia UnitGeared Type Fitted with the Frame.
    • Oxygen Inlet6 Mm Festo Connection from Rear Bottom ,(straight)

    Function 

    The Flow Head incorporates the following Functions

    • Gas indexed pneumatic inlet ports
    • N20 gas flow cut off in the event of oxygen failure
    • Flow control needle valves
    • N20/O2 flow ratio hypoxic mixture prevention proportioning system
    • Color coded, marked specific labels for flow tubes and flow control valves
    • Gas mixing chamber, mixed gas outlet

     

     

    GENERAL OPERATION

    The Flow Head integrates O2 and N20.

    The 02 Air and N20 needle valves gas supply pressure is externally regulated to 400Kpai10Kpa as per standard.

    The N20 channel incorporates a pressure cut-oft valve. The 02 supply pressure in the circuit controls the output pressure of the pressure cut-off valve. Under all conditions of operation, the N20 flow shall reach zero before the 02 flow. In this flow head the N20 pressure switch shall cut off the flow of N20 before the 02 pressure drops below 50:15Kpa.

     

    PERFORMANCE STANDARDS

    Standard flow conditions defined at 20°C, 101 .3Kpa, (760mmHg) Conforms to ISO 5358 requirements.

    Flow Tubes

    •  Flow Tubes are calibrated for discharge into an ambient atmosphere of 101 .3Kpa at an operating temperature of 20°C.
    • Each flow tube shall be calibrated to accuracy of 110% of reading, or better.
    • Flow tubes withstand 690Kpa internal pressure without breaking.

    Flow Control Valves

    • Anti-clockwise rotation shall cause an increase inflow.
    • Flow control knob are color coded and touch coded. Smooth and precise rotation ensures accurate flow setting

     

    PRESSURE CUT-OFF VALVE

    • N20 regulated pressure shall drop with falling of 02 supply pressure and shall prograssively reduce flow of this gas while
    • maintaining the proportion of 02 (22% min.) until O2 pressure falls to 50i15Kpa at which point the supply of N20 shall be cut off.
    • The only means of restoring N20 flow after 02 supply failure (O2 pressure below 50i15Kpa) shall be the restoration of 02 pressure.

    ASSEMBLY

    Leakage from atmosphere shall not exceed 108ml/min. when a vacuum of 80cm H20 is applied to all internal.

    MATERIALS

    • All wetted material are compatible with all gases used and all anaesthetic agents.
    • Equipment compiles with HoHS requirements.


    Download


    Download Detail File : Click Here
    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry

    Product Images

    • Dual Tube Flowmeter With AHD
    • Dual Tube Flowmeter With AHD
    • Dual Tube Flowmeter With AHD
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Dual Tube Flowmeter With AHD?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice