Company Information
Ask for more detail from the seller
Contact SupplierSCOPE :-
HOLYSCIENTIFIC is one of the leading science equipment manufacturer & exporter our equipments are widely used in many industries like laboratory sterilization, clean room, microbiology, pathology, bio technology, pharmaceuticals, seed & soil testing, metallurgical, food processing and many more. Cloud & pour point apparatus is widely used in oil and petroleum industries.
USAGES :-
FEATURES
MODE OF HEATING :-
RASAYAN cloud & pour is made according to specification laid by IP by 15 & ASTM D 97. The Pour Point is lowest temperature at which the oil will just fail to flow. The apparatus consists main cooling bath made out of S.S. Sheet and stand Unit with drain Plug and cover has provision for fitting thermometer and a filling adventure for adding freezing mixture. A Glass Jar for containing Oils, Jackets, Disc and gasket as specified are also provided. Bench-model and floor-model test units with multiple four-jacket mechanically refrigerated baths, each factory preset at a different temperature for convenient cloud and pour point testing. Bench model has three baths, set at +30, 0, and –30°C floor model has four baths, set at +30, 0, –30 and –60°C. Each bath has a S.S made top plate with ports for thermometer and four copper test jackets. Synthetic sponge covers over each top plate and gasket hoods over each bath prevent excessive ice accumulation around the test jackets. Cascade hermetic refrigeration system provides reliable long term service. Bath interior and cabinet is constructed entirely of stainless steel. Cloud & Pour Point Appratus, Floor model rides on swivel castors. Supplied with test jackets, gaskets, disks, and thermometer holders for test jars and cooling baths.
| Model No* | Test position | No.of tank | Temperature range |
| RCP1A | 2/4 as per requirement | Single | 00C to -650C |
| RCP2A | Two | 00C and -170C | |
| RCP3A | Three | 00C ,-170C and -340C | |
| RCP4A | Four | 0°C, -17°C, -34°C, -51°C. | |
| RCP5A | Five | 0°C, -17°C, -34°C, -51°C and -65°C |
| Testing procedure meets | As per ASTM D97( Pour) & ASTM D 2500 (Cloud) |
|---|---|
| Model | Floor / table top type |
| Temperature range | Refer STANDARD MODELS |
| Temperature control | + 2°C |
| Ambient Temp. Recommendation | < 25.0°C |
| Display Resolution & Control Sensitivity | 0.1°C |
| Control Readout | Actual and Set point |
| Controller | Digital Microprocessor based PID/ON-OFF |
| Sensor | Pt 100 (RTD)- 3 wire |
| Stirrer | Maintain temperature uniformity (optional if required) |
| Cooling up to -35°C | CFC free Single stage refrigeration system for each tank |
| Cooling below -35°C | CFC free Double stage (Cascade) refrigeration system for each tank |
| Heating | Provided only for better accuracy (optional if required) |
| Alarm type | Deviation High or Low |
| Inner tank | Stainless steel 304 grade dully polished |
| Outer | Mild steel CRCA sheet with powder coating |
| Test positions | Refer STANDARD MODELS |
| Compressor | Hermetically sealed Emerson make |
| Condensor | Fin and tube air cooled |
| Refrigerant | CFC Free R134a/ R404a & Suva 95 |
| Insulation | High density PUF – Poly Urethane Foam |
| Wheels | For easy moving with front locking facility |
| Accessories | Copper Jacket, Test jars, Disc, Gasket, Cork for each test positions of each tank |
| Power supply | Single Phase – 230VAC, 50Hz |
| Voltage Stabilizer | For refrigeration system |
|---|---|
| Thermometer | As per IP IC |
| NABL Certified Calibration Certificate | For temperature controller |
| Data Logging | PC interface through RS232 Communication module |