Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    Electromagnetic flow meter, Frequency : 50 Hz

    • ViscosityUp to 3000 cp
    • Design PressureUp to 15 Kg/cm2
    • Measuring Range0.1 to 350M3/hr
    • Fluid:Liquids
    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 11 Years
    • building Nature of Business Retailer
    • Year of Establishment 2014

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • Velocity Range0.5m/s to 10m/s
    • ViscosityUp to 3000 cp
    • Sp. GravityUp to 2.95
    • Design PressureUp to 15 Kg/cm2
    • Fluid:Liquids
    • Measuring Range0.1 to 350M3/hr

    Process Control Devices offers a series of digital flow meters. Design to measures the flow rate of a liquid flowing through the close pipe. The electromagnetic flow meter is volumetric flow meter having no obstruction as there are no moving parts. Hence pressure drop is negligible. The performance is independent of density, viscosity, temperature, and pressure of the flowing liquidThe magnetic flow meter is calibrate using water and can measure the flow of other conductive fluids, with no further correction. This is a special feature that other type of flow meters doesn’t have. PCD is one of the leading Electromagnetic flow meter manufacturers in Mumbai India.

     

    Working Principle of Electromagnetic Flow Meter

     

    Electromagnetic flow meters work on the principle of “Faraday’s Law of electromagnetic induction”. According to the law, “when a conductive liquid cut the magnetic field, voltage Induce”. Further, that voltage signal is sensed by the electrode which is mounted on the wall of the flow tube. That induce voltage signal is process by the electronic transmitter to determine the flow. The generation of voltage is directly proportional to the velocity of the fluid.

     

     

    Construction of Electromagnetic Flow Meter

    Electronic Part consists of head type Flow Indicator which contains Microprocessor Controller chip mounted on the electronic circuit. It has the LCD display, Which shows the Current flow rate & Total commutative flow. Also, has a transmission feature of 4-20 mA output & RS 485 Communication with High & Low Flow Alarm. To operate it requires an external power supply of 24 VDC or 230 VAC.

     

    The mechanical part consists of Flow Tube, Lining such as of PTFE Or Neoprene, Electrode, Magnetic Coil, Flange connection. Flow Tube Material is non-wetted part and should be of the nonmagnetic material such as SS 304 Or SS 316. Selection of Lining Material must be according to temperature, corrosive property & compatibility of the measured fluid. Neoprene can resist general weak acid, alkaline corrosion and can withstand temperature unto 80ËšC, but it has wear resistance. As PTFE (Teflon) has low wear resistance and have good compatibility to almost all strong acid, chemical, alkaline corrosion, ETP Water, Waste Slurry. And can withstand temperature up to 180ËšC. Selection of Electrode Material must be according to corrosiveness of measured fluid.

     

    Mechanical Specification

    Line Size: 15 NB to 300 NB

    Lining Material: PTFE, EPDM, NEOPRENE

    Electrode Material: SS316,  Hastelloy C, Titanium, Monel

    Design Temperature: Up to 150 DegC

    Connection: Flanged to ASA, BS, DIN

     

    Electronics Specifications

    Programming: By Membrane Key

    Power Supply: 24 VDC Isolated, 230 VAC, 110VAC

    Out Puts: 4-20mA, 4wire, Pulse,

    Communication : RS 485 MODBUS

    Accuracy: ± 1% of FSD & ± 0.5% on request

    Linearity: +/- 0.5 %

    Repeatability: 0.5%

     

    Silent Features
    • Total / accumulated total / flow rate
    • Auto empty-full pipe check
    • Ultrafast response time
    • 4-20mA and pulse output
    • high and low alarm (2-relay output)
    • Modbus (RS485)
    • Can handle slurries and heavy particulates
    • Good accuracy (0.5 to 1%)
    • Can respond well to fast changing flows
    • Insensitivity to viscosity, specific gravity, temperature and pressure (within certain limitations)
    • Will work with laminar, turbulent, and transitional flows
    • Virtually no pressure drop
    • No moving parts
    • Lining protectors available for harsh, chemically corrosive, and abrasive fluids
    • Can respond well to fast changing flows


    Additional Information

    • Payment Terms L/C
    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for electromagnetic flow meter?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice