Company Information
Ask for more detail from the seller
Contact Supplier| Electromagnetic flowmeter | 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600 |
|---|---|
| Rubber Lined Pipe | 40, 50, 65, 80, 100, 125, 150, 200, 300, 350, 400, 500, 600, 800, 1000, 1200, note: special specifications can be customized |
| Flow direction | positive and negative, net flows Turndown |
| Measuring range ratio | 150:1 |
| Repeatability error | +/-0.1% |
| Accuracy | piped: 0.5 class, 1.0 class |
| Measured medium temperature | Common rubber lining: -20~+60 oC |
| High temperature rubber lining: -20~+90 oC | |
| PTFE lining: -30~+100 oC | |
| High temperature vinyl lining: -30~+180 oC | |
| Rated working pressure | pipeline: DN10~DN65: ≤ 2.5MPa;DN80~DN150: ≤ 1.6MPa; DN200~DN1200: ≤ 1.0MPa |
| Flow measuring range | flow measuring range corresponding to flow rate range is 0.3~15m/s |
| Measured fluid conductivity | 5μs/cm (Most with water as the composition of the medium, its conductivity in the range 200~800 Mu s/cm, optional solenoid flow) |
| Output | Current:4~20mADC (isolation), pulse frequency 0~1kHz, OCT photoelectric isolation, external power ≤ 35VDC, breakover, collector Max 25mA |
| Load resistance | < 600 Ω |
| Electrode material | 316L, titanium (Ti), tantalum (Ta), Hastelloy, (h), Platinum (Pt) or other special electrode materials |
| Protection grade | standard: IP65; IP68 |
| Working power supply | 85~265VAC 45~63HZ |
| Straight pipe length | pipe: ≥ 5DN in the upper reaches, downstream of greater than or equal to 2DN |
| Connections | flow meter connected to the piping is used between flanges, flange connection dimensions comply with GB9119-88 requirements. |
| Explosion-proof mark | mdllBT4 |
| environment temperature | -25 oC ~=60 oC |
| Relative humidity | 5%~95% |
| Total power consumption | <20W |