Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    Environmental Test Chamber

    • Supply TypeManufacturer, Exporter, Supplier
    • Preferred Buyer Location All over the world

    INTRODUCTION For Environmental Chamber in Ahmedabad, Environmental Chamber in Baroda And Surat “NOVA” Environmental Test Chamber can generate & maintain above ambient temp.,below ambient....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 18 Years
    • building Nature of Business Manufacturer
    • Year of Establishment 1985

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    INTRODUCTION For Environmental Chamber in Ahmedabad, Environmental Chamber in Baroda And Surat

    “NOVA” Environmental Test Chamber can generate & maintain above ambient temp.,below ambient temp.,and humidity. It is specifically designed for application of various testing under low temp.& with control humidity.

     
    APPLICATION:

    These test chambers are used for climatic and durable Test of electrical & Electronic apparatus, Control penal, Electronic components, Material & components, Chemical Testing, Pharmaceuticals, Geological testing, Conditioning Samples prior to electrical/electronic test as well as TQA Requirement test etc.etc. It can be used as a simulated Tropical & extreme tropical conditions. Nova Instruments For Environmental Chamber in Ahmedabad, Environmental Chamber in Baroda, Environmental Chamber in Surat. 

    SALIENT FEATURES:
    • Fully automatic, temp. control-Micro control Based.
    • Easy to operate.
    • Top Control Penal.
    • Obstruction free working space.
    • Digi. Temp. Indicator & Control (Micro Control)
    • Sensitive Temperature sensor Pt-100 type.
    • Floor model.
    • Castor wheel for easy move ability.
    • Elegant outlook, enamel painted/powder coated.
    • Glass door/window to see through.
    • Forced air circulation.
    • Humidity Control by dry & wet principal.
    • Digital Humidity Indication (Optional).
    • Stainless Steel steam boiler.
    • Panel Meters- Volt & Ampere.
    • Suitable for climatic & durable tests.
    • Auto Water level 
    • CONSTRUCTION:
      The unit is of double walled construction. The exterior chamber is made of mild steel and finished in non corrosive paint or powder coated and interior chamber is made of heavy gauge polished stainless steel. Between two chamber glass-wool /  thermocole  insulation is provided. Glass window/Door is provided to see the operation without disturbing the control condition inside the chamber. An outside metal door with lock is provided. The unit rest on castor wheel.
       
      HEATING:
      [A] Chamber is heated by long lasting air heater to eliminate failure of heater.
      [B] Boiler heater is of immersion type heater.
       
      COOLING:
      Using hermetically sealed compressor coupled with evaporation coil & fan cooled condenser.
       
      HUMIDITY :
      Humidity generated by steam injection near the duck from a boiler connected to water tank fitted with water level controller. Humidity set & derived by dry & wet bulb principles by the provided depression chart.
       
      INDICATION & CONTROL :
      Digital display indication for temperatures. Fully automatic solid state electronic controllers with Pt-100 sensors for both dry & wet bulb controllers are panel type easy for maintenance/service.
       
      CONTROL PANEL:

      Control panel is provided on the top of the unit consisting of Mains switch, Mains indicator, Ampere meter, Voltmeter, Wet bulb Digital Indicator cum Controller, Wet bulb Indication pilot lamp, Dry bulb Digital Indicator cum Controller, Dry bulb indication pilot lamp (For cooling cycle-heating cycles), Low water level controller fitted and connected through circuit to boiler heater low level pilot lamp (will not glow if water level is below requirements), Door heater switch (Optional), Chamber light switch  (Optional).



    CAPACITY (Cuft)INNER DIMN. IN CMS (H x W x D)TEMP. RANGE
    ACCU.+/-1 DEG.C
    HUMIDITY RANGE ACCU.+/-3% RHINNER CHAMBER
    6 Cuft70 x 50 x 5010 to 60 Deg. C.5% 
    Above 
    Ambient
    to  
    95% RH
    Stainless Steel
    8 Cuft80 x 55 x 5010 to 60 Deg. C.Stainless Steel
    10 Cuft90 x 55 x 5510 to 60 Deg. C.Stainless Steel
    12 Cuft90 x 65 x 5810 to 60 Deg. C.Stainless Steel
    16 Cuft90 x 70 x 7010 to 60 Deg. C.Stainless Steel





    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Environmental Test Chamber?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice