Company Information
Ask for more detail from the seller
Contact SupplierWe are offering fetal monitor.
this series is a lightweight, compact fetal and maternal monitor, it can meet the need of whole
stages of labor (including antepartum and intrapartum monitoring for fetus and mother),it also
can be connected to the obstetrical central station
features
1.7”tft colour screen,folding 90 degree;
2.the internal line thermal printer can records fhr ,toco ,the life period can exceed over 20years;
5.auto fetal movement counting with monitoring curve and data display;
3.1mhz,9 crystal safer wide beam pulse wave transducer; 4.low consumption ultrasound transducer, it's safe for fetus monitoring;
5.ac or li-battery operated;
6.more than 10 hours data storage, then can be reviewed and printed;
7.built-in communication interface to the central nurse station.
5specification
fhr measure
measure mode
ultrasonic doppler
measurement range
50~210bpm
measure accuracy:
≤±2bpm
fhr wave arrange
50~210bpm
fhr digital display arrange
50~210bpm
strength
<5mwcm2
working frequency
1.0mhz
toco measure
measure mode
external measurement
measurement range
0-100 units
measure accuracy
≤±10%
toco curve range
0-100 units
toco digital range
0-100 units
automatic reset function
yes
maternal spo2 measure
measurement range
70%~99%
measure accuracy
±3%
nibp measure
nibp-sys
6.7~32.0kpa(50~240mmhg)
nibp-dia
3.4~26.6kpa(25~200mmhg)
nibp-mean
2.0~24.0ka(15~180mmhg)
nibp accuracy
±1.1kpa(±8mmhg)or ±5% of results, taking the bigger one
measure mode
manualautomatic
pregnant hr measure
measurement range
40bpm~240bpm
measure accuracy
±2 bpm
fetal movement marker
icon of fetal movement button in manual
fetal movement detected automatically
event marker
marked by doctor for clinical event
display screens
7” tft 480*234
record mode
thermal dot matrix printer system
record paper
112mm folded thermal printer paper
paper skip speed
1、2、3cmmin, accuracy ±5%
fetal heart rate alarming limit
lower limit, 90, 100, 110, 120 bpm optional.
upper limit, 160, 170, 180, 190 bpm optional
alm delay
15 seconds or 30 seconds optional
alarming for printer problems
al_paper: out of paper
al_cover: printer panel not closed or not closed completely.
maximum audio output power
<1.5w
power
ac: 100-240v,5060hz,20va
dc: 7.4v2200mah rechargeable lithium battery
dimension
295d*240w*73h(mm)
weight
1.75kg
probe connecting line
2.7~2.95m
network interface
rs232 ,tipip
working environment
temperature: +5℃ ~ +40℃
humidity:
atmospheric pressure: 86kpa ~ 106kpa
storage temperature:
temperature: -10℃ ~ +55℃
humidity:
atmospheric pressure: 86kpa ~ 106kpa.