Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    Filter Units

    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world

    The Sentinel range of filter units has been specially developed for the filtration of electroplating solutions and the range of capacities available will meet the majority of automatic and manual....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 11 Years
    • building Nature of Business Retailer

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    The Sentinel range of filter units has been specially developed for the filtration of electroplating solutions and the range of capacities available will meet the majority of automatic and manual plating installation requirements.

    Sentinel filter units are totally enclosed, provide a large filtration area, are easy to clean and maintain, and provide effective retention of activated carbon or filter aids.

    The filters are designed to take plate packs and the standard units incorporate a rubber lined centrifugal pump.

    Applications:

    Sentinel filters may be used on the majority of electroplating solutions including:

    • NICKEL - bright, semi-bright, dull
    • ZINC - cyanide, alkaline, acid, neutral
    • TIN - acid, stannate
    • COPPER - cyanide, pyrophosphate
    • CADMIUM - cyanide, acid, neutral.

    For the following solutions sentinel filters fitted with special pumps can be supplied:

    • flourborate and fluoride based solutions
    • acid copper
    • acid tin (including bright solution.)
    • solutions containing free hydrochloric acid e.g. nickel chloride strike solutions.

    Sentinel filters are not suitable for the filtration of chromium plating solutions.

    Filtration of anodising solutions: For sulphuric acid anodising solutions standard Sentinel filter units are advised.Sentinel fiter units are supplied in three sizes having one, two and three filter containers respectively. The filter contains are made of steel with a special quality high temperature cured rubber lining and are mounted on a sturdy tubular steel cradle. On standard units the motor-driven pump is mounted within the cradle, below the filter container. The single and double container units are fitted with castors for ease of movement, the three-container unit is provided with mountings for foundation bolts.

    Filter Pack: Sentinel filter are supplied with a plate type pack as described on the reverse. Packs can easily be removed from the container for cleaning of replacement without the use of a hoist, and to simplify this operation valves are fitted to the individual containers in case of larger filter units to enable them to be drained of solution.

    Centrifugal Pump: The Standard Sentinel filter units incorporate close coupled centrifugal pumps designed for filtration duties. A non-metallic/stainless steel impeller housed in a rubber lined cast iron body is used with an immersed type.

    Mechanical seal. Alternatively magnetically coupled, seals monoblock pumps can also be supplied. The filter units are supplied complete with a suitable motor, mounted on the tubular frame. A valve is fitted to the pump inlet to permit the unit be isolated.

    Pipework: Sentinel filters are provided with flanged inlets and outlets, permitting when required, direct connection to rigid plastic or rubber lined steel pipework. The units are supplies complete with two 3 metre (10ft.) lengths of reinforced acid resistant polypropylene hose including appropriate spigots.

    Sentinel filter units can be supplied as part of comprehensice solution handling facilities incorporating features such as:

    • Transfer of solution from plating tank to storage.
    • Solution circulation for heat exchangers and low current density plating out-units.
    • Chemical make-up tanks.
    • Plating solution purification treatments.


    Units with mechanical sealSealless units
    Model NOXSingleDoubleTripleTyneeNOXSingleDouble
    Code No. 952302952401952501952601952201952305952402952502
    Overall Lengthmm860860114517005506008601145
    Overall Widthmm735735735840450450735735
    Overall Heightmm92010651065114555067010651065
    No. of containersnos11231112
    No. of clothesnos8163248881632
    No. of platesnos9173451991734
    Cloth aream20.61.12.23.30.60.61.12.2
    Clean flow capacityLt/hr22504500900013500800180045009000
    Pack ChangesLt/hr112522504500900040090022504500
    Hose boremm3030305025253030
    Motor hphp0.52350.080.160.52
    Elec. inputkw0.381052.23.70.060.120.381.5
    Nett weightkg1201402303258590115200
    Gross weightkg170200290410110120175270
    Case lengthmm101610161320185062068010161320
    Case widthmm762762813879510510762813
    Case heightmm106711681168125062075011681168
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Filter Units?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice