    Carbon Steel NAF S125, Color : Red

    • MaterialCarbon Steel
    • ApplicationIndustrial use
    • FeatureHard Structure, Industry Proven Design, Less Maintenance, Superior Functional
    • Number Of FlowerFire Suppression Systems
    • ConditionNew
    • Supply TypeExporter, Supplier, Retailer
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 10 Years
    • building Nature of Business Retailer
    • gst icon GST No. 08AAQCA5025Q1Z2

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details

    Product Details no_img_icon

    • Number Of FlowerFire Suppression Systems
    • MaterialCarbon Steel
    • ApplicationIndustrial use
    • FeatureHard Structure, Industry Proven Design, Less Maintenance, Superior Functional
    • ConditionNew

    NAF® S 125 is a UL Recognized and US EPA SNAP Listed gaseous extinguishing agent. NAF® S 125 Engineered Systems are UL Listed.
    NAF® S 125 is suitable for use in rooms, vaults, enclosed machines, containers, storage areas and wherever fixed enclosures are present. It is an electrically non-conductive media, it can therefore be used to protect electronic and delicate equipment. After discharge NAF® S 125 does not require the clean-up of the protected enclosure, making it extremely useful in applications where damage by other extinguishing methods would be prohibitive.
    NAF® S 125 has a low order of toxicity. At typical design concentrations it can be safely used to protect normally occupied areas.
    The NAF S 125® formulation includes a patented additive that reduces the levels of decomposition by-products normally generated by halocarbons during extinguishment and enhances extinguishing performance (inter alia US Patent No. 6,402,975 and EU Patent No. 630,278).
    By weight NAF® S 125 requires the lowest concentration, making NAF® S 125 the most cost effective clean agent solution available in the market today.

     

    They are available in 180º and 360º coverage that is suitable for total flooding systems in occupied areas. This Gas Suppression System protects areas such as computers, archives, electrical and telecommunications equipment, Server Room/Data Center, Hospitals, Petrochemical, Offshore, Airport, Laboratories, Paint Booths, etc. The typical design concentration of this Gas Suppression System is 8%, with a discharge time of 10 seconds in accordance with the UL 2166 regulations.
    Discharge is via valves that have been completely designed by manufacturer and certified by the top independent agencies. This gas suppression system offers great flexibility of adaptation to all actuation systems currently on the market, and even allows combinations of several of these. This gas suppression system design incorporates elements that protect against accidental activation due to micro-seepage. All of the valves are registered through the Ministry of Industry and thus comply with an obligatory standard. The NAF S125 extinguishing systems include discharge nozzles especially designed to maximize the properties of the extinguishing agent. They are available in 180º and 360º coverage. 
    Main benefits :

    • 20% Gas less required in comparison of FM200 System
    • Maximum reduction of fire damage / Rapid intervention
    • Maximum safety in the area
    • Excellent cost/benefit ratio
    • Low maintenance cost
    • Low space occupied / low installation weight
    • Maximum safety for personnel
    • Maximum flexibility of use / rapid distribution


    Certificates :

    • The NAF S125 are certified by the LPCB (loss prevention certification board) of England no.: 108640 / BC9933
    • APCI (Cuba certification body) no : SS 4004040-1102
    • Certified by the UL (Underwriters Laboratories) : UL is a non-profit independent organization that guarantees the safety of systems and components: NAF S125 has now added the UL stamp of quality to their traditional system of quality (ISO 9001: 2000). This vouches for the design of the systems (extinguishing concentration and network calculation software); the reliability of the components and the production quality - both of the components and the extinguishing agents as well.


    Physical Properties

    CompositionHFC-125 + 0.15% of Limonene
    Molecular weight120.0
    Boiling point @ 1.013 bar-48.3°C
    Density of the liquid @ 25°C1189.7 kg/m³
    Critical temperature339.45 K
    Critical pressure3595 Kpa
    Vapor pressure @ 20°C12.09 bar
    Relative electrical resistance @ 1 atm. 21°C (N2=1.0)0.955

     

    NFPA 2001 Edition 2012

    Design concentration for Class A Fires8.7% (by volume)
    Flooding factor for Class A Fires0.484 kg/m³
    Design concentration for Class C Fires9% (by volume)
    Flooding factor for Class C Fires0.502 kg/m³

     

    ISO 14520 Edition 2006

    Design concentration for Class A/C Fires8.7% (by volume)
    Flooding factor for Class A/C Fires0.484 kg/m³
    PBPK (5 minutes exposure)11.5%
    Ozone Depletion Potential (ODP)0
    Global Warming potential (GWP)2800

     

    Share your requirements for a quick response!
    Tell us what you need?

    Looking for NAF S125?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice