Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Marsz Blue Automatic Furnace Transformer, for Industrial, Phase : Single Phase

Listing ID #7126399

  • MOQ 1 Piece
  • PhaseSingle Phase
  • Country of OriginIndia
  • Brand NameMarsz
  • ColorBlue
  • Supply Type Exporter, Supplier, Trader
Preferred Buyer From : All Countries Except India
View More Details
Send Enquiry

Company Information

  • Member Since 14 Years
  • Nature of Business Manufacturer
  • GST No. 27AAPCM8700R1ZL

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Phase Single Phase
  • Country of Origin India
  • Brand Name Marsz
  • Color Blue
  • Condition New
  • Automatic Grade Automatic
  • Application Industrial
  • Cooling Type Oil Cooled

MARSZ manufactures Arc, Submerged Arc, Ladle, Induction furnace transformers upto 10 MVA, Upto 33kV, ONAN / OFWF cooling.

 

A high current furnace transformer is provided by having the low-voltage windings arranged in a closed delta configuration within the transformer enclosure. Bus bar terminals are mounted exterior to the enclosure for providing electrical connection with the low-voltage windings.

 

MARSZ Furnace transformers are used to step down from voltages between 11 and 33 kV to levels of several hundred volts only. This results in massive secondary currents. As an example a 30 MVA unit at 150 V would result in a secondary current of 115 kilo Ampere. For these high secondary currents special bushings are required to connect to the bus-bars. These bushings are specified with very specific arrangements to suit the bus-bar arrangement and cooling system. Furnace bus-bars are mostly water cooled. Due to the high secondary currents and resistive losses the furnace layout is such as to limit the bus-bar length.

 

The MARSZ furnace transformers are then located close to the furnace itself and if they are single phase units, arranged in a triangle around the furnace. This means that there is a high risk of fire, a high ambient temperature and this whole set up is located at a level associated with the third story of the building. The location above ground level encourages single phase units due to the structural limitations of the buildings. To reduce the fire risk the transformers are contained in rooms, which adds to the high ambient temperature.

 

MARSZ Furnace transformers are very much used in a production environment. Loading of these transformers is then very close to rated values and even beyond. This demands very reliable transformers. Shutdowns due to transformer problems are frowned upon. When shutdowns occur, the problem needs to be solved quickly. This in turn calls for good accessibility of the tap changer and other parts of the transformer. Large inspection covers in close proximity to the tap changer are often specified.

 

Due to the nature of the process MARSZ furnace transformers are specified with large tapping ranges. Thirty tap positions is not uncommon. Adding to the wide tapping range is the utilisation of the tap changer. Some users require up to 800 operations of the tap changer per day. This demands high maintainability and efforts to increase the maintenance intervals. On line tap changer oil filters are thus essential. To reduce downtime further, plug-in type diverters are specified. This allows a quick changeover of the diverter switch and an overhaul in a workshop environment with more time at hand.

 

Another aspect of the process is the large number of short circuits that these transformers are subjected to every day. Transformers associated with open arc furnaces can be subjected to a number of short circuits per melt as the material being melted collapses across the electrodes. Bus-bar flash overs are also a fact of life on most furnace installations. To add to this peril, MARSZ furnace transformers are required to have a lower than normal impedance. This gives rise to higher over-current factors. Very robust design in terms of the transformers’ ability to withstand the dynamic effects of repeated short circuits is required. Minimum impedance values for furnace transformers of the core type are in the order of 4 – 5 %. To achieve lower values, one would need a shell type transformer. Upper levels for impedance could be any value from 10 to 24 % depending on the configuration and tapping range.

 

Application in following industries :

Chemical, Pharmaceuticals, Steel, Textile, Engineering, Plastic, Cement, Refineries, Mining, Captive Power Projects, Hydro Power Projects, Wind Mill Farms, Construction Houses, Pharma, Electrical, Electronics, Renewable Energy, Automobile.


Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry

Company Details close-icon

Marsz Electricals Pvt. Ltd. was established in the year 2021 in Maharashtra, India. We are manufacturer and trader of transformer, diesel generator, mobile lighting tower and a lot more.

 

It has to its credit the reputation of being strong in the application of manufacturing of transformers and the core team has an accumulated experience of more than fifteen years. The company has a fleet of well-experienced technocrats and management personnel to implement its plan and program for its prospective growth both shortly and in the long run. In all circumstances, quality is the essence of our company\'s activities.

 

The Company is equipped with a full range of required testing instruments and machinery as per the International Code of Practice in addition to Indian Standard Specification (ISS) for all routine tests. 

 

All Special type tests are carried on periodically as per customers\' requirements.

We are a professionally managed leading Company with a skilled work force and having state of the art manufacturing, Engineering and testing facility at our premises. We have the setup to design and develop innovative, bespoke solutions to even the most challenging customer requirements.

 

Outstanding Customer Service

 

As a family-owned company, we take great pride in treating our customers with the respect and attention they rightfully deserve. We are big enough to look after all your transformer requirements yet small enough to care, unlike many large multinational companies where customer service seems to have gone out of Fashion.

  • Nature of Business Manufacturer / Exporter / Supplier / Trader
  • Number of Employees 20 - 50
  • Year of Establishment 2021
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Furnace Transformer?

Quantity
Seller Contact Details
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice