Company Information
Ask for more detail from the seller
Contact Supplier| Silicon Carbide Heating Elements in matched sets ensure better temperature uniformity and longer element life. Â Elements mounted horizontally or vertically. | |
| Internal hot face lining made of special refractory slabs backed by low heat capacity refractory and other insulations of different grades. | |
Multi-tap Transformer/s with Selector Switches or Thyristorised Power Controls, for regulating power-input and element-ageing.  Special provision for Element inter-connection change-over for match-maintenance of heating elements.  Over-temperature protection, optional. CHAMBER types up to 1500°C : Floor mounting construction with upper portion comprising the front-loading heating chamber.  Control Panel and Transformer/s or Thyristor Drive/s housed in the lower portion.  Insert type swing-aside parallel moving Door. Platform/Table models for smaller sizes. APPLICATIONS : Trial firing and testing of P.L.C.A.R. of refractories ; Heat-treatment, precision batch firings, laboratory testing, | |
| T'maxa | Modela | Cavity Size (mm) | Hrs. to T'max | KW a | ||
| W | H | D | ||||
| 1400°C | 40C 2* | 125 | 95 | 225 | 3.0 | 2.0 |
| 40C 4/4Y* | 125 | 125 | 250 | 3.0 | 2.5 | |
| 40C 5 | 150 | 125 | 300 | 3.0 | 4.0 | |
| 40C 6Y* | 150 | 150 | 250 | 3.5 | 3.5 | |
| 1450°C | 45C 2* | 125 | 95 | 225 | 3.0 | 2.5 |
| 45C 7 | 150 | 150 | 300 | 3.0 | 5.2 | |
| 45C 12Y* | 200 | 200 | 300 | 2.5 | 6.0 | |
| 45C 20 | 250 | 200 | 400 | 3.0 | 10.0 | |
| 45C 42 | 300 | 300 | 450 | 3.5 | 12.0 | |
| 45C 54Y | 300 | 300 | 600 | 6.0 | 14.0 | |
| 45C 96Y | 400 | 400 | 600 | 5.0 | 18.0 | |
| 1500°C | 50C 9 | 200 | 150 | 300 | 3.0 | 7.5 |
| 50C 35Y | 250 | 300 | 450 | 3.5 | 12.0 | |
| 'Y' for Thyristorised Power Control | ||||||
| '*' denotes Table models | ||||||