    Insertion Electromagnetic Flow Transmitter, For Conductive Liquids., Feature : Easy To Use, Proper Working

    • ApplicationConductive Liquids.
    • FeatureEasy To Use, Proper Working
    • Number Of FlowerInsertion Electromagnetic Flow Transmitter
    • Total Carbohydrate1year
    • CpnditionNew
    • Supply TypeManufacturer, Exporter, Supplier, Retailer, Distributor, Importer, Trader, Buying House
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 15 Years
    • building Nature of Business Supplier
    • gst icon GST No. 07AOSPS8386M1ZM

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • Number Of FlowerInsertion Electromagnetic Flow Transmitter
    • ApplicationConductive Liquids.
    • FeatureEasy To Use, Proper Working
    • Total Carbohydrate1year
    • CpnditionNew

    insertion electromagnetic flow transmitter

    series ief insertion electromagnetic flow transmitter

    field configurable, high accuracy, bacnet or modbus® protocol

    a-ief remote display is now available!

    the series ief insertion electromagnetic flow transmitter is an adjustable insertion flowmeter featuring electromagnetic technology that accurately and reliably measures fluid velocity in addition to providing several continuous signal outputs. This series is specifically designed to offer superior performance paired with simple installation and use. One unit is adjustable to fit pipe sizes from 4 to 36" (101.6 to 914.4 mm), and offers several output options including selectable bacnet ms/tp or modbus® rtu communications protocol over 2-wire rs-485 in addition to the standard analog, frequency and alarm outputs.

    dwyer instruments, inc. Was recognized for excellence in product design in the 15th annual dealer design awards program sponsored by the air conditioning heating & refrigeration news magazine. An independent panel of contractors acted as judges in the contest that had 98 entries. The company’s insertion electromagnetic flow transmitter was the bronze award winner in the testing and monitoring product category. The achr news is the leading trade magazine in the heating, ventilating, air conditioning, and refrigeration industries. To read the full announcements, please visit https://www.dwyer-inst.com/2018ddabronzewinner.

    specifications

    • service:compatible clean or dirty non coating, conductive liquids.
    • range:0 to 20 ft/s (0 to 6 m/s).
    • wetted materials:body shaft/fitting: 316ss; electrodes: 316ss; electrode cap: polymer/polystyrene; o-ring: silicon.
    • accuracy:high accuracy units: ±0.5% of reading at calibrated velocity; ±1% of reading from 2 to 20 ft/s (0.6 to 6 m/s); ±0.02 ft/s (±0.006 m/s) at < 2 ft/s (0.6 m/s);
    • standard accuracy units: ±1% fs.
    • temperature limits:ambient: -20 to 160°f (-29 to 71°c); process: 15 to 250°f (-9 to 121°c); storage: -40 to 185°f (-40 to 85°c).
    • process connection:1" npt or bspt with accessory full port ball valve options.
    • pressure limits:400 psi (27.6 bar) @ 100º f (37.8°c).
    • pressure drop:< 0.1 psi at 12 ft/s in 4" (101.6 mm) and larger pipe.
    • outputs:(1) analog: 4 to 20 ma, 0 to 5 v, 0 to 10 v or 2 to 10 v (display selectable);
    • (1) pulse/frequency: 0 to 15 v peak pulse, 0 to 500 hz or scalable pulse output (display selectable);
    • (2) alarm: (1) empty pipe detection or minimum/maximum velocity, (display selectable);
    • (1) reverse flow output indication.
    • power requirements:12 to 42.4 vdc, .25 a @ 24 vdc; 12 to 36 vac.
    • electrical connection:removable terminal blocks, model selectable 1/2" female npt conduit connection, pg 16 gland or pg 16 gland with (2) 10' (3 m) 9 conductor 22 awg plenum rated cables, accessory cable lengths up to 200' (61 m) optional.
    • display:2" ( 5.08 cm) x 2" (5.08 cm) graphic lcd with backlight.
    • conductivity:>20 microsiemens.
    • enclosure material:powder coated die cast aluminum.
    • enclosure ratings:nema 6p (ip68) (non display models); nema 4x (ip66) (-lcd option).
    • agency approvals:btl, ce, nsf/ansi 61 and 372.
    • communications (-com option)
    • type:bacnet ms/tp or modbus® rtu communication protocol (default disabled, display selectable).
    • supported baud rates:9600, 19200, 38400, 57600, 76800, or 115200 bps (display selectable).
    • device load:1/8 unit load.

     


    Additional Information

    • Payment Terms L/C, D/A, D/P, T/T, Western Union
    • Port of DispatchDELHI
    • Delivery Time4-6 WEEK

    Product Images

    • Insertion Electromagnetic Flow Transmitter
    • Insertion Electromagnetic Flow Transmitter
    • Insertion Electromagnetic Flow Transmitter
    • Insertion Electromagnetic Flow Transmitter
    • Insertion Electromagnetic Flow Transmitter
    • Insertion Electromagnetic Flow Transmitter
    • Insertion Electromagnetic Flow Transmitter
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Insertion Electromagnetic Flow Transmitter?

    Quantity
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice