    Ground Fault Monitoring System

    • Current Setting Range300 mA to 12 Amps. In step - 300mA / 500mA / 750mA / 1.00A / 1.25 / 1.50 / 1.75 / 2.50 / 3.00 / 4.00 / 5.00 / 6.00 / 7.00 / 8.00 / 9.00 / 10.00 / 11.00 / 12.00
    • Tripping Time0.0 Second top 5 Seconds in step of 0.05 Sec
    • Operating Temperature-5 to 55 C.
    • Core Balance Current TransformerMoulded case CBCT with open circuit detection.
    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 7 Years
    • building Nature of Business Retailer
    • gst icon GST No. 27AAHFN9779L1Z9

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • Instantaneous Tripping Timeless than 35 msec.
    • Current Setting Range300 mA to 12 Amps. In step - 300mA / 500mA / 750mA / 1.00A / 1.25 / 1.50 / 1.75 / 2.50 / 3.00 / 4.00 / 5.00 / 6.00 / 7.00 / 8.00 / 9.00 / 10.00 / 11.00 / 12.00
    • Potential Free contact2 Change Over Contact for Tripping and Alarm.
    • Core Balance Current TransformerMoulded case CBCT with open circuit detection.
    • CommunicationRS. 485 (Optional)
    • Tripping Time0.0 Second top 5 Seconds in step of 0.05 Sec
    • Operating Temperature-5 to 55 C.

    At Neelkanth you will get the best ground fault monitoring system Mumbai at an affordable price. We are a reliable and trusted manufacturer and supplier of electrical devices that are required in different sectors.

    When planning for electrical system protection, the ground faults present far more common and in aggregate potentially more dangerous occurrences for personnel and the equipment that are used. Bonding, grounding and ground fault protection are extremely vital for reducing the hazards of electrical shocks to the personnel during a ground fault like when a current carrying conducting insulator fails or inadvertently faults to the ground.

    Choosing our products for ground fault protection will allow the electrical system to stay maintained and in a reliable manner matching the needs or loads that it serves to isolate undesirable fault conditions In a quick and ideally selective way.

    Why Choose Us?

    Our products are tested and certified by experts. These are made with advanced machines and technologies and helps in ground fault protection for specific equipment like transformers, generators, motors and much more.

    A ground fault usually occurs when the conductor at a voltage other than the earth reference comes in contact with another conductive material that is connected to the ground. Depending on those of the installed grounding system, this can lead to the sustained or transient overvoltage and under-voltage to an undesirable single like to the ground fault currents. These faults can often harm the systems and cause event losses. This is the reason why choosing our products is the best choice for different customers and clients.

    Following are some more reasons why you should choose our products and use them for detecting ground faults.

    • Provides you with a common reference point

    • Improves safety

    • Protects your equipment in the best way possible

    • Ground fault locations can be detected easily

    • Allows you better control of transient overvoltages

    • Electrostatic accidents can be better avoided

    We have a micro-controlled based ground fault detector in our company as well. Choose us and get our products today.


    Technical Specification

    Supply Voltage230V 50 HzMeasuring accuracy with closed transformer+/- 5%
    Power consumption70 VAwith split transformer+/- 10%
    Measuring range Alarm settings30 mA to 9999mA
    Local measuring point10mA to 11ATime delay settingto 99 sec.
    Remote measuring point30mA to 11AAlarm relay--
    Measuring length--one relay for 16 channels 2 pcs change
    over contacts max 30 VAC 1.25A
    --
    Local channelmax 300 ftRemote channelmax 3000 ft

    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Ground Fault Monitoring System?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice