Company Information
Ask for more detail from the seller
Contact SupplierIndustrial High Voltage X Ray Control Unit Specifications(example for High Voltage Control unit of 450KV machine):  English operation interface  PLC intelligent microcomputer operation, touching screen displaying  Filament automatic preheating  Voltage controlling and indication:50~450kV,step distance 1kV,precision ±0.5%             Repeatability:±0.005% of max voltage value (under normal temperature)  Current controlling and indication: Big focus 1~10mA,step distance 0.1mA,precision ±0.5% Small focus 1~2mA,step distance 0.1mA,precision ±0.5% Tube voltage, current preset, preset value can be adjust continuously, system also have up-limit and hardware protection.  Exposure time preset and indication:0~999min random setting  Working mode selection:"RTR" and "Filming"  Indication of tube temperature  Multiple protection for on-off high voltage, match with key switch, avoid misusing of X-ray machine. It has sound reminder when open or close the voltage  Automatic and manual aging status selection, for automatic aging can set up-limit voltage and current according to using requirement.  Big/small focal working status selection, operated by key switch, and prevent destroy the X-ray tube when transmit the focus during HV on, and inside of procedure it has focus interlock protection functions.  Working time acceleration Â