    Instrument Signal Cables

    • Supply TypeManufacturer, Exporter, Supplier
    • Preferred Buyer Location All over the world

    Construction: Conductor Bare / tinned electrolytic annealed copper conductor. Solid, stranded or flexible confirming to BS 6360 and IS 8130. Refer Table 1 for details. Insulation : PVC or HR PVC....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 21 Years
    • building Nature of Business Manufacturer
    • Year of Establishment 1982

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    Construction: Conductor

    Bare / tinned electrolytic annealed copper conductor. Solid, stranded or flexible confirming to BS 6360 and IS 8130. Refer Table 1 for details.

    Insulation :

    PVC or HR PVC insulation in accordance with IS 5831. Polyethylene insulation in accordance with BS 6234 / IS 6474.

    Twisting and Laying :

    Required numbers of cores are laid up in case of multicore core cables. Individual pairs, triads or quads are formed by uniformly twisting the insulated cores with short lay lengths, prior to laying.

    Core Identification :

    Cores can be colour coded or number printed for easy identification. In case of multi pair cables one core in each pair is number printed in words as well as in figures at short intervals of 50mm or a numbered polyester tape is provided over each pair.

    Overall Screen :

    After final lay up of the complete cable an overall screen of aluminium-polyester tape is applied along with 0.5 sqmm multi stranded annealed tinned copper (ATC) drain wire in continuous electrical contact with aluminium side of the tape. Tinned copper braid screening can also be provided.

    Individual & Overall Screen :

    Individual pairs, triads or quads are screened by aluminium-polyester tape along with 0.5 sqmm ATC drain wire and overall screened by aluminium-polyester tape as mentioned above. Tinned copper braid screening can also be provided. 
    In case of individually screened cables for critical applications an extruded isolation sheath can also be provided over the individual screens.

    Assembly Binder :

    After final assembly a non-hygroscopic polyester tape is provided to act as a binder as well as a bedding for the outer screening in all cables.

    Armour:

    Galvanized steel round wire or strip armour in accordance with BS 5308 / IS 1554 respectively. The armour wire and strip confirms to IS 3975. If required, G.I square interlock armour or G.I / S.S wire braid armour can also be provided.

    Inner & Outer Sheath :

    PVC, HR, FRLS PVC or ZHLSF sheath in accordance with IS 5831 can be provided. U.V stabilized Polyethylene sheath can also be provided for hazardous areas. A blue colour outer sheath for intrinsically safe areas can be provided on request. A pair of communication wires can be provided if desired.



    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Instrument Signal Cables?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice