    Interferential Therapy

    • Patient SafetyAvailable
    • Preset Programs50 program
    • 0-200 HzDIADYNAMIC CURRENT
    • RUSSIAN CURRENTMedium Frequency
    • Supply TypeSupplier
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 16 Years
    • building Nature of Business Retailer
    • Year of Establishment 1998

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • Absorption46-Watts Max
    • Probe TestCable & Electrode Test
    • Moisture10% to 80%
    • Base AMF0-250 Hz
    • Vector Mode2PL, 4PL, 4PT, 4PNL
    • Customize Program99 Create Programs
    • Treatment Time01 to 99 Minutes adjustable
    • 0-200 HzDIADYNAMIC CURRENT
    • Max Output Voltage100V (Peak to Peak)
    • 2.5 KHzBase AMF
    • Low Frequency50Hz & 100Hz
    • Max. Output Current100mA Digital Display for CH-1 & CH-2
    • 0-200 HzSpectrum
    • Spectrum0-250 Hz
    • Preset Programs50 program
    • Medium Frequency2 KHz& 4 KHz
    • Patient SafetyAvailable
    • Therapy Mode4P, 4PV, 2P
    • Operating Voltage110-270V 50Hz
    • Fuses1 Amp
    • Current ModeCP, LP, DF, MF
    • Room Temperature10ºC to 40ºC
    • Wave shapeTra, Tri, Rec.
    • RUSSIAN CURRENTMedium Frequency
    • Weight)5 Kg Approx.
    • Dimension (L*H*D)352mm, 125mm, 331mm

    The effects of tissue stimulation with these 'medium frequency' currents (medium frequency in electromedical terms is usually considered to be 1KHz-100KHz) has yet to be established. It is unlikely to do nothing at all, but in terms of current practice, little is known of its physiological effects. It is not capable of direct stimulation of nerve in the common context of such stimulation.
    Physiotherapy Interferential therapy utilizes two of these medium frequency currents, passed through the tissues simultaneously, where they are set up so that their paths cross & they literally interfere with each other. This interference gives rise to an interference (beat frequency) which has the characteristics of low frequency stimulation – in effect the interference mimics a low frequency stimulation.
    The exact frequency of the resultant beat frequency can be controlled by the input frequencies. If for example, one current was at 4000Hz and its companion current at 3900Hz, the resultant beat frequency would be at 100Hz, carried on a medium frequency 3950Hz amplitude modulated current.
    By careful manipulation of the input currents it is possible to achieve any beat frequency that you might wish to use clinically. Modern machines usually offer frequencies of 1-150Hz, though some offer a choice of up to 250Hz or more. To a greater extent, the therapist does not have to concern themselves with the input frequencies, but simply with the appropriate beat frequency which is selected directly from the machine.

     

    ELECTRODES, CONTACT AND SAFETY

    Virtually all interferential clinical units are supplied with carbon rubber electrodes. The clinician should be aware that either water soaked sponges or a conducting gel should always be used between the electrode and the tissue. This will insure a uniform contact and provide for even disbursement of the current over the entire surface area of the electrode. If water only is used as a conductive agent, pooling may occur with resulting dry spots under the electrode. The current will then become intensified at the site of best conduction, the water pools, with little or no current flow elsewhere. With "true interferential therapy device" units this could result in over stimulation of tissue under the water pools and even possible tissue burns as depolarized tissue will not be able to sense the over stimulation.
    While some ift interferential still offer the vacuum electrode system, many clinicians have discontinued their use. Extra maintenance, tissue bruising and uneven current flow have been cited as reasons for a reduction in the popularity of vacuum systems.
    Self adhesive electrodes are rapidly becoming the favorite of clinicians due to the ease of use, patient acceptance and elimination of possible cross-contamination. Difficult to apply areas such as shoulders, hips and the cervical spine are easily treated with the self-adhesive electrodes. Also, recent improvements in adhesive agents have made longer use possible and prices have been reduced substantially.
    If carbon rubber electrodes are used, care should be taken to insure proper current flow. When conductive gels are used, the gel will create a glaze over the surface of the electrodes with long-term use. The glaze may prevent the flow of current over the entire electrode surface. Cleaning the electrode periodically with a mild soap and water and soft brush is recommended. It is not a good practice to use conducting mist sprays in lieu of other conducting agents. This is due to the saline content of the sprays which has been shown to destroy the carbon content of the electrode, thus rendering the electrode useless.

    The best selection for this device is re-usable Silver Connector Electrodes.
     

    Intensity oF Current
    Interferential therapy unit provides a comfortable, soothing stimulation and should never be strong enough to cause any discomfort to the patient. Higher intensities should not be considered "better" as far as obtaining results. It is important to note that once the patients comfort level is established at the onset of therapy, the intensity should not be increased during the treatment.



    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Interferential Therapy?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice