Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

KABIR Admittance Level Switches, Certification : ISO 9000-2001

Listing ID #1541889

2,087.50 / Piece
Get Latest Price
  • MOQ 1 Piece(s)
  • Brand NameKABIR
  • CertificationISO 9000-2001
  • Model NumberSMLS-09
  • Place of OriginVADODARA
  • Supply Type Supplier
Preferred Buyer From : All over the world
View More Details
Send Enquiry

Company Information

  • Member Since 12 Years
  • Nature of Business Manufacturer
  • GST No. 24AANFK0752A1ZS

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Based in Vadodara, Gujarat, we are an esteemed manufacturer and supplier of Admittance Level Switches. Admittance Level Switch is used to measure level precisely. The Switch comprises of an evaluation unit and an immune coat probe which is usually mounted on the vessel. In order to achieve highest accuracy, the Switch makes use of 3-Electrode technique with a driven shield arrangement. The Calibration controls of these Switches are set-up in the evaluation unit, which also comprises of a special ten LED dot display. Our Admittance Level Switches are highly preferred by the clients, for their precision in measurements.

 

Detrails :

  • Admittance based level switch with RF signal transmission between probe and evaluation unit via a co-axial cable with drain wire having driven shield arrangement to eliminate cable capacitance and drift due to change of cable capacitance with temperature. You can install the evaluation unit even far from the probe. The calibration controls are available in the evaluation unit. A special ten LED dot display/bar display simplifies calibration and indicates material trend in vicinity of the point level.
  • The SLA...M Seriesswitch can be efficiently used to reduce the inventory as the same evaluation unit can be field configured either for High or Low level fail-safe detection. The SLA...M series Ignores build-up of service material between probe, the vessel walls and the coating. The level limit switch uses 3-Electrode technique with driven shield arrangement to achieve high degree of immunity.
    The measuring system for this level limit detection tool consists of an evaluation unit and an immune-coat probe that could be mounted either from the top or side of the vessel. The probe comprises sense and shield electrodes electrically isolated from the metallic tank by means of suitable insulators. The sense electrode of the switch and the vessel wall serve as the two electrodes of a capacitor with the service material as the dielectric. A change in material level causes a change in dielectric, which in turn causes a change in admittance of this tank capacitor.
  •  The processed signal is used to energize or de-energize a relay whose output contacts are available for annunciation or control.
  •  An accurate measurement of this change affords an indirect measure of the level of material in the tank. The evaluation unit measures the change of admittance accurately by using radio frequency (R.F.) technique coupled with coat immunizing circuitry.
  • Many process industries viz. cement, power, steel, food, chemicals, fertilizer, sugar, detergent etc. have been using the SLA...M series for reliably measuring and self checking the level of service material which may include fine or coarse solids of low dielectric constant that have a tendency to stick. 
  • A wide variety of probes with different mounting connections is available to suit various applications. We offer specially designed ceramic insulated rod / rope probe suitable for operating temperatures up to 600° C max.

 

Note : 

  • Bar display is recommended for longer distance between probe and evaluation unit and for materials having tendency to absorb moisture.
  • A wide variety of probes with different mounting connections is available to suit various applications. We offer specially designed ceramic insulated rod / rope probe suitable for operating temperatures up to 6000 C max.


Technical Data Evaluation Unit

Housing Cast Aluminum, weather proof, back panel / wall mounting.
Cable Entries 3 No. / 2 No.
Max. Amb. Temp. -20º C to + 60º C.
Power Consumption 5 VA approx.
Mains Voltage 230 V or 110 V AC (-15% to +10%), 50 Hz; 24 V AC/DC 90 to 260 V AC universal power supply (to be specified while ordering).
Relay Output One/two set (s) of potential free change over contacts rated at 230V AC 6A, 50 Hz for non-inductive loads.
Fail-Safe Mode Max. or Min. field selectable.
Indication (switching) Red LED for alarm, Green LED for normal.
Indication (sensitivity) 10 step LED dot / bar display
Response Time 0.2 second typical.
Switching Delay Adjustable from 0.5 to 20 second for probe covered or uncovered.
Connection to Probe Via co-axial screened cable with drain wire.
Switching Hysteresis 0.2 pF. typical.

Additional Information

  • Payment Terms T/T
  • Port of Dispatch MUMBAI
  • Packaging Details Wooden cages & Bubble sheet.
  • Delivery Time WITHIN A WEEK

Product Images

  • Admittance Level Switches
  • Admittance Level Switches
  • Admittance Level Switches

Company Details close-icon

We are pleased to introduce ourselves as one of the leading Quality manufacturers of FLOW, LEVEL, PRESSURE AND TEMPRATURE INSTRUMENTS based at Vadodara an industrial town in western India.
“KABIR INSTRUMENTS & TECHNOLOGY” was established by Mr. Rikesh Bhagat, Mr. Sunil Bhagat & Mr. Ketan Patel in 2011 with the aim of manufacturing process control Instruments such as Rota Meters (Glass & Metal Tube), Acrylic Body Rota Meters, By-Pass Rota Meters, Orifice Flange Assemblies with accessories, Electromagnetic Flow meters, Level Instruments (i.e. Indicators, Gauges, Switches, Transmitters), Sight Flow Indicators (Sight Glasses Full View, Double Window & Single Window type), Manometers, Toughened Glasses , Pressure Gauges, Temperature Gauges, Temperature Elements (i.e. RTD PT 100, Thermocouples) which find application in a wide range of manufacturing processes in a wide spectrum of industries. We are currently exporting to Asian Countries such as UAE, Malaysia.
  • Nature of Business Manufacturer / Exporter / Supplier
  • Number of Employees Below 20
  • Year of Establishment 2012
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Admittance Level Switches?

Quantity
Seller Contact Details
  • Seller Kabir Instruments & Technology
  • Address Makarpura, Vadodara, Gujarat
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
KABIR Admittance Level Switches, Certification : ISO 9000-2001 at USD 25 / Piece in Vadodara
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

KABIR Admittance Level Switches, Certification : ISO 9000-2001

Listing ID #1541889

2,087.50 / Piece
Get Latest Price
  • MOQ 1 Piece(s)
  • Brand NameKABIR
  • CertificationISO 9000-2001
  • Place of OriginVADODARA
  • Model NumberSMLS-09
  • Supply Type Supplier
Preferred Buyer From : All over the world
View More Details
Send Enquiry

Company Information

  • Member Since 12 Years
  • Nature of Business Manufacturer
  • GST No. 24AANFK0752A1ZS

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Based in Vadodara, Gujarat, we are an esteemed manufacturer and supplier of Admittance Level Switches. Admittance Level Switch is used to measure level precisely. The Switch comprises of an evaluation unit and an immune coat probe which is usually mounted on the vessel. In order to achieve highest accuracy, the Switch makes use of 3-Electrode technique with a driven shield arrangement. The Calibration controls of these Switches are set-up in the evaluation unit, which also comprises of a special ten LED dot display. Our Admittance Level Switches are highly preferred by the clients, for their precision in measurements.

 

Detrails :

  • Admittance based level switch with RF signal transmission between probe and evaluation unit via a co-axial cable with drain wire having driven shield arrangement to eliminate cable capacitance and drift due to change of cable capacitance with temperature. You can install the evaluation unit even far from the probe. The calibration controls are available in the evaluation unit. A special ten LED dot display/bar display simplifies calibration and indicates material trend in vicinity of the point level.
  • The SLA...M Seriesswitch can be efficiently used to reduce the inventory as the same evaluation unit can be field configured either for High or Low level fail-safe detection. The SLA...M series Ignores build-up of service material between probe, the vessel walls and the coating. The level limit switch uses 3-Electrode technique with driven shield arrangement to achieve high degree of immunity.
    The measuring system for this level limit detection tool consists of an evaluation unit and an immune-coat probe that could be mounted either from the top or side of the vessel. The probe comprises sense and shield electrodes electrically isolated from the metallic tank by means of suitable insulators. The sense electrode of the switch and the vessel wall serve as the two electrodes of a capacitor with the service material as the dielectric. A change in material level causes a change in dielectric, which in turn causes a change in admittance of this tank capacitor.
  •  The processed signal is used to energize or de-energize a relay whose output contacts are available for annunciation or control.
  •  An accurate measurement of this change affords an indirect measure of the level of material in the tank. The evaluation unit measures the change of admittance accurately by using radio frequency (R.F.) technique coupled with coat immunizing circuitry.
  • Many process industries viz. cement, power, steel, food, chemicals, fertilizer, sugar, detergent etc. have been using the SLA...M series for reliably measuring and self checking the level of service material which may include fine or coarse solids of low dielectric constant that have a tendency to stick. 
  • A wide variety of probes with different mounting connections is available to suit various applications. We offer specially designed ceramic insulated rod / rope probe suitable for operating temperatures up to 600° C max.

 

Note : 

  • Bar display is recommended for longer distance between probe and evaluation unit and for materials having tendency to absorb moisture.
  • A wide variety of probes with different mounting connections is available to suit various applications. We offer specially designed ceramic insulated rod / rope probe suitable for operating temperatures up to 6000 C max.


Technical Data Evaluation Unit

Housing Cast Aluminum, weather proof, back panel / wall mounting.
Cable Entries 3 No. / 2 No.
Max. Amb. Temp. -20º C to + 60º C.
Power Consumption 5 VA approx.
Mains Voltage 230 V or 110 V AC (-15% to +10%), 50 Hz; 24 V AC/DC 90 to 260 V AC universal power supply (to be specified while ordering).
Relay Output One/two set (s) of potential free change over contacts rated at 230V AC 6A, 50 Hz for non-inductive loads.
Fail-Safe Mode Max. or Min. field selectable.
Indication (switching) Red LED for alarm, Green LED for normal.
Indication (sensitivity) 10 step LED dot / bar display
Response Time 0.2 second typical.
Switching Delay Adjustable from 0.5 to 20 second for probe covered or uncovered.
Connection to Probe Via co-axial screened cable with drain wire.
Switching Hysteresis 0.2 pF. typical.

Additional Information

  • Payment Terms T/T
  • Port of Dispatch MUMBAI
  • Packaging Details Wooden cages & Bubble sheet.
  • Delivery Time WITHIN A WEEK

Product Images

  • Admittance Level Switches
  • Admittance Level Switches
  • Admittance Level Switches

Company Details close-icon

We are pleased to introduce ourselves as one of the leading Quality manufacturers of FLOW, LEVEL, PRESSURE AND TEMPRATURE INSTRUMENTS based at Vadodara an industrial town in western India.
“KABIR INSTRUMENTS & TECHNOLOGY” was established by Mr. Rikesh Bhagat, Mr. Sunil Bhagat & Mr. Ketan Patel in 2011 with the aim of manufacturing process control Instruments such as Rota Meters (Glass & Metal Tube), Acrylic Body Rota Meters, By-Pass Rota Meters, Orifice Flange Assemblies with accessories, Electromagnetic Flow meters, Level Instruments (i.e. Indicators, Gauges, Switches, Transmitters), Sight Flow Indicators (Sight Glasses Full View, Double Window & Single Window type), Manometers, Toughened Glasses , Pressure Gauges, Temperature Gauges, Temperature Elements (i.e. RTD PT 100, Thermocouples) which find application in a wide range of manufacturing processes in a wide spectrum of industries. We are currently exporting to Asian Countries such as UAE, Malaysia.
  • Nature of Business Manufacturer / Exporter / Supplier
  • Number of Employees Below 20
  • Year of Establishment 2012
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Admittance Level Switches?

Quantity
Seller Contact Details
  • Seller Kabir Instruments & Technology
  • Address Makarpura, Vadodara, Gujarat
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice