Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    Heat Transfer In Forced Convection, Certification : ISO 9001:2008 Certified

    • MOQ1 Piece(s)
    • CertificationISO 9001:2008 Certified
    • Total CarbohydrateYes
    • Country of OriginIndia
    • Heat Transfer LabHeat Transfer in Natural Convection
    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 9 Years
    • building Nature of Business Retailer
    • Year of Establishment 2010

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • CertificationISO 9001:2008 Certified
    • Total CarbohydrateYes
    • Country of OriginIndia
    • Brand NameSLISCO
    • Heat Transfer LabHeat Transfer in Natural Convection
    • Heat Transfer LabParrallel & Counter Flow Heat Exchanger
    • Heat Transfer LabStefan Boltzman Apparatus

    Product description:our company offers best quality heat transfer in forced convection at an affordable market price. The apparatus offered by us is utilized for measuring average surface heat transfer coefficient or the reynolds number for a pipe losing heat under forced convection conditions. Manufactured under strict supervision in accordance with industry set norms and parameters, this apparatus is appreciated by the clients for compact design, seamless finishing and longer functional life.
    Description:
    � the apparatus consists of blower unit fitted with the test pipe.
    Â�¢ nichrome wire heater surrounds the test section. Four temperature sensors are embedded on the test section, two placed in the air stream at the entrance and exit of the test section to measure the inlet and outlet air temperature.
    Â�¢ test pipe is connected to the delivery side of the blower along with the orifice to measure flow of air through the pipe.
    Â�¢ constant heat flux is given to pipe by an electric heater through a variac and measured by digital voltmeter and digital ammeter.


    Additional Information

    • Payment Terms L/C, D/A, D/PT/T
    • Delivery Time7 days
    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Heat Transfer In Forced Convection?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice