    Alpha Test House has built a testing facilities for LED & Luminaries Testing which is certified by ISO 9001:2015 & accredited by NABL & approved by BIS. The Laboratory is also providing BEE Regulator....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 13 Years
    • building Nature of Business Retailer

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Service Details

    • Company Details

    no_img_icon

    Alpha Test House has built a testing facilities for LED & Luminaries Testing which is certified by ISO 9001:2015 & accredited by NABL & approved by BIS. The Laboratory is also providing BEE Regulator accepted Testing. The Objectives of BEE Standards & Labeling Program is to provide the consumer an informed choice about the energy saving and thereby the cost saving potential of the marketed household and other equipment like LED LAMPS, Color TV, Electric Geysers, Computer (Notebook/Laptops), Office Equipments (Printer, Copier, Scanner) etc.

    The laboratory has installed a latest & highest reliable & branded Goniophotometer, Spectrophotometer, Integrating Sphere, LED Lamp, Led Luminaries, Led Control gear Test Instruments, CFL Test Instruments, Photometer and Colorimeter, Electrical Safety Testing, Environmental Testing, AC and DC Power Supply and etc.

    The laboratory also provide Ingress Protection Testing at a competitive price including Safety testing, Vibration testing, LM79 etc.


    Many products undergo a variety of tests before they reach the market. These tests include product safety testing, electromagnetic compatibility, vibration testing and many others. Products used indoors or outdoors are often tested against "ingress," that is, the product's resistance to water, dust and foreign objects. There are several reasons for ingress testing, including safety, functionality and product marketing. We provide Ingress Protection Testing in very competitive price including Safety testing, Vibration testing, LM79 etc.



    Following products are covered under Compulsory Registration Scheme:

    Sl. No.

    Product

    Indian Standard number( IS No.)

    1

    SELF-BALLASTED LED LAMPS FOR GENERAL LIGHTING SERVICES

    IS 16102(Part 1):2012

    2

    DC OR AC SUPPLIED ELECTRONIC CONTROLGEAR FOR LED MODULES

    IS 15885 (Part 2/Sec13) 2012+A1:  2015

    3

    FIXED GENERAL PURPOSE LED LUMINAIRES

    IS 10322(Part 5/Sec 1):2012

    4

    Recessed LED Luminaries

    IS 10322 (Part 5/Section 2) : 2012

    5

    LED Luminaries for Road and Street lighting

    IS 10322 (Part 5/Section 3) : 2012

    6

    LED Flood Lights

    IS 10322 (Part 5/Section 5) : 2013

    7

    LED Hand lamps

    IS 10322 (Part 5/Section 6) : 2013

    8

    LED Lighting Chains

    IS 10322 (Part 5/Section 7) : 2013

    9

    LED Luminaries for Emergency Lighting

    IS 10322 (Part 5/Section 8) : 2013

    Luminaries- Particular Requirements- Fixed General purpose Luminaries:

    Specific tests performed

    Standard against which tests are performed

    Marking

     Cl. 6 of IS 10322 (Part5/Sec 1): 2012/ IEC 60598-2-1: 1979+ A1: 1987 Cl. 1.5 of EN 60598-2-1: 1997

    Construction

    Cl. 7 of IS 10322 (Part5/Sec 1): 2012/IEC 60598-2-1: 1979+ A1: 1987 
    Cl. 1.6 of EN 60598-2-1: 1997

    Creepage Distance and Clearances

    Clause 8 Of IS 10322 (Part5/Sec 1): 2012/IEC 60598-2-1: 1979+ A1: 1987
    Clause 1.7 of EN 60598-2-1: 1997

    Provision for Earthing

    Clause 9 of IS 10322 (Part5/Sec 1): 2012/IEC 60598-2-1: 1979+ A1: 1987
    Clause 1.8 of EN 60598-2-1: 1997

    Terminals

    IS 10322 (Part5/Sec 1): 2012 Clause 10 IEC 60598-2-1: 1979+ A1: 1987
    Clause 1.9 of EN 60598-2-1: 1997

    External and Internal Wiring

    Clause 11 IS 10322 (Part5/Sec 1): 2012/IEC 60598-2-1: 1979+ A1: 1987 Clause 1.10             of EN 60598-2-1: 1997

    Protection Against Electric shock

    Clause 12 of IS 10322 (Part5/Sec 1): 2012/IEC 60598-2-1: 1979+ A1: 1987 Clause 1.11 of EN 60598-2-1: 1997

    Endurance Tests and Thermal Tests

    Clause 13 of IS 10322 (Part5/Sec 1): 2012/IEC 60598-2-1: 1979+ A1: 1987 Clause 1.12 of EN 60598-2-1: 1997

    Resistance to Dust and Moisture

    Clause 14 of IS 10322 (Part5/Sec 1): 2012/IEC 60598-2-1: 1979+ A1: 1987
    Clause 1.13 of EN 60598-2-1: 1997

    Insulation Resistance and Electric Strength

    Clause 15 of IS 10322 (Part5/Sec 1): 2012 /IEC 60598-2-1: 1979+ A1: 1987
    Clause 1.14 of EN 60598-2-1: 1997

    Resistance to Heat, Fire and Tracking

    IS 10322 (Part5/Sec 1): 2012 Clause 16 IEC 60598-2-1: 1979+ A1: 1987
    Clause 1.15 EN 60598-2-1: 1997

    Safety of Lamp Control gear Part 2: Particular Requirement Section : 13 d.c. or a.c. Supplied Electronic Control gear for LED Modules

    Specific tests performed

    Standard against which tests are performed

    Marking

    IS 15885 (Part 2/ Sec 13): 2012 IEC 61347-2-13, Ed2:2014 EN 61347-2-13: 2006,Clause No: 7

    Protection against accidental contact with live parts

    IS 15885 (Part 2/ Sec 13): 2012 IEC 61347-2-13, Ed2:2014 EN 61347-2-13: 2006,Clause No: 8

    Terminals

    IS 15885 (Part 2/ Sec 13): 2012 IEC 61347-2-13, Ed2:2014 EN 61347-2-13: 2006,Clause No: 9

    Provision for Protective Earthing

    IS 15885 (Part 2/ Sec 13): 2012,IEC 61347-2-13, Ed2:2014 EN 61347-2-13: 2006,Clause No: 10

    Moisture Resistance and insulation

    IS 15885 (Part 2/ Sec 13): 2012 IEC 61347-2-13, Ed2:2014 EN 61347-2-13: 2006,Clause No: 11

    Electric Strength

    IS 15885 (Part 2/ Sec 13): 2012 IEC 61347-2-13, Ed2:2014 EN 61347-2-13: 2006,Clause No: 12

    Fault conditions

    IS 15885 (Part 2/ Sec 13): 2012 IEC 61347-2-13, Ed2:2014 EN 61347-2-13: 2006,Clause No: 14

    Construction

    Clause No: 16 of IS 15885 (Part 2/ Sec 13): 2012/
    IEC 61347-2-13, Ed2:2014 Clause No: 17 of 
    EN 61347-2-13: 2006

    Creepage Distance and clearance

    Clause No: 17 of IS 15885 (Part 2/ Sec 13): 2012
    IEC 61347-2-13, Ed2:2014 Clause No: 18 of EN 61347-2-13: 2006,

    Screws, current- carrying parts and connections

    Clause No: 18 of IS 15885 (Part 2/ Sec 13): 2012/ IEC 61347-2-13, Ed2:2014 Cl. 19EN 61347-2-13: 2006,

    Resistance to heat, fire and tracking

    Clause No: 19 IS 15885 (Part 2/ Sec 13): 2012/Clause No: 19 IEC 61347-2-13, Ed2:2014
    Clause No: 20 of EN 61347-2-13: 2006,

    Self-Ballasted LED Lamps For general purpose Lighting Services ,Safety Requirements IS:16102(Part 1):2012, IEC 62560:2011+A1:2015

    Specific tests performed

    Standard against which tests are performed

    Marking

    Cl. 5 of IS:16102
    (Part 1):2012/IEC 62560:2011

    Interchangeability

    Cl. 6 of IS:16102
    (Part 1):2012/IEC 62560:2011

    Protection Against accidental Contact With Live Parts

    Cl. 7 of IS:16102
    (Part 1):2012/IEC 62560:2011

    Insulation Resistance and Electric Strength Test After Humidity

    Cl. 8 of IS:16102
    (Part 1):2012/IEC 62560:2011

    Mechanical Strength

    Cl. 9 of IS:16102
    (Part 1):2012/IEC 62560:2011

    Cap Temperature Rise Test

    Cl. 10 of IS:16102
    (Part 1):2012/IEC 62560:2011

    Resistance To Heat

    Cl. 11 of IS:16102
    (Part 1):2012/IEC 62560:2011

    Resistance to Flame and Ignition

    Cl. 12 of IS:16102
    (Part 1):2012/IEC 62560:2011

    Fault Conditions

    Cl. 13 of IS:16102
    (Part 1):2012/IEC 62560:2011

    Creepage Distance And Clearances

    Cl. 14 of IS:16102
    (Part 1):2012/IEC 62560:2011

    Secondary cells and batteries containing alkaline or other non-acid electrolytes-safety requirements for portable sealed secondary cells, and for batteries made from them ,for use in portable applications IS 16046:2015,IEC 62133:2012

    Specific tests performed

    Standard against which tests are performed

    Continuous low-ratse charging

    Cl. 7.2.1 & Cl. 8.2.1
    of IS 16046:2015/IEC 62133:2012

    Vibration

    Cl. 7.2.2 & 8.2.2
    of IS 16046:2015/IEC 62133:2012

    Molded case Stress

    Cl. 7.2.3 & 7.2.4
    of IS 16046:2015/IEC 62133:2012

    Temperature cycling

    Cl. 7.2.4
    of IS 16046:2015/IEC 62133:2012

    Incorrect installation

    Cl. 7.3.1
    of IS 16046:2015/IEC 62133:2012

    External short circuit

    Cl. 7.3.2 & 8.3.2
    of IS 16046:2015/IEC 62133:2012

    Free Fall

    Cl. 7.3.3 & 8.3.3
    of IS 16046:2015/IEC 62133:2012

    Mechanical shock(crash hazards)

    Cl. 7.3.4
    of IS 16046:2015/IEC 62133:2012

    Thermal abuse

    Cl. 7.3.5 & 8.3.4
    of IS 16046:2015/IEC 62133:2012

    Low pressure

    Cl. 7.3.7
    of IS 16046:2015/IEC 62133:2012

    Overcharge

    Cl. 7.3.8 & 8.3.6
    of IS 16046:2015/IEC 62133:2012

    Force discharge

    Cl. 7.3.9 & 8.3.7
    of IS 16046:2015/IEC 62133:2012


































    Share your requirements for a quick response!
    Tell us what you need?

    Looking for LED and Luminaries Testing?

    Quantity
    Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice