    Magnetic Flowmeter

    • Ambient Temperature25°C~+60°C
    • Nominal Pressure0.6~4.0MPa
    • Supply TypeManufacturer, Exporter, Supplier
    • Preferred Buyer Location All over the world

    Accuracy: ±0.5% of reading. ±0.3% is available upon request. Damping Time Constant: 0~100s (90%) selectable. Display and Buttons: Large LCD display with backlight. Display the instantaneous flow,....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 12 Years
    • building Nature of Business Supplier

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details

    Product Details no_img_icon

    Accuracy: ±0.5% of reading. ±0.3% is available upon request.
    Damping Time Constant: 0~100s (90%) selectable.
    Display and Buttons: Large LCD display with backlight. Display the instantaneous flow, total flow, and alarm.
    Totalizer: Three built-in totalizers: forward flow totalizer, reverse flow totalizer and net totalizer.
    Output Signals:
    Analog output: Bi-directional, isolated 0~•10mA4~20mA. Load resistor: 0~1.5ΚΩ for 0~10mA, 0~750Ω for 4~20mA
    Frequency output: Forward & reverse flow output with the frequency range of 1~5000Hz. The external voltage must be lower than 35V and the max output current must be 250mA when the transistor is turned on.
    Alarm output: Two isolated Open Collector Transistor (OCT) outputs for alarm signals. The external voltage must be lower than 35V and the max output current must be 250mA when the transistor is turned on. Alarm will be activated when the pipe is empty, the excitation circuits are broken or the volume of flow rate exceeds the value of designed limits.
    Pulse output: the OCT circuit is used for forward or reverse flowrate output. The upper frequency of the output pulse can be up to 5000cps. The relevant value of pulse is from 0.0001 to 1.0m3cp. Pulse width can be set to 20ms or 50% occupancy. The external voltage must be lower than 35V and maximum output current must be 250mA when the transistor is on.


    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Magnetic Flowmeter?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice