Contact SupplierWe are offering modular patient monitor.
Features:
1 modular design with higher integration, more stable functions, and lower power consumption, easy to replace
2 12 inch high definition color tft display
acdc available, suitable for ward bedsides, icu care and operating room
3 standard six-parameter module: ecg, hr, nibp, spo2, resp and temp
4 monitor and analysis: arrhythmia analysis, st segment analysis, drug concentration and titration table calculation
5 nibp measurement using a double overpressure protection technology to prevent injury from high inflation pressure
6 720 hours of trend data playback, 2 hours of waves playback, up to 1000 bp review, up to 200 alarm events review
7 3-level intelligent alarms: sound, light and voice alert, volume adjustable
8 support wired networking, support mixed network connection
specification of neuroplus series modular patient monitor
ecg
lead type: 35 leads electric cable
input: 3 leads: ra, la, ll (lead method: i, ii, iii)
5 leads: ra, la, ll, rl, v (lead method: i, ii, iii, avr, avl, avf, v)
gain: 250, 500, 1000, 2000
heart rate range: 15~300bpm (adult), 15~350bpm (child & neonate)
accuracy: ±1bpm or ±1%, whichever is bigger
resolution: 1bpm
sensitivity: >200uv (peak to peak)
input impedance: >5mω
bandwidth: diagnosis model: 0.05~130hz, monitoring: 0.5~40hz, operation: 1~20hz
cmrr: diagnosis model: >90db, monitoring model: >100db, operation model: >100db
electrode polarization and voltage range: 300mv
pacemaker impulses amplitude: ±2mv~ ±700mv, width: 0.1ms~2ms, rise time: 10us~100µs
recovery time:
signal range: 8 mv peak to peak
calibrate signal: 1mv peak to peak; accuracy: 5%
st detection: range: -2.0mv~ +2.0mv, accuracy: -0.8 mv~ +0.8mv, error: ±0.02mv±10%
arrhythmia analysis (13 kinds):
nibp (noninvasive blood pressure)
method: pulse wave oscillation
operation mode: manualautomaticcontinuous
time interval (automatic): 1min, 2mins, 3mins, 4mins, 5mins, 10mins, 15mins, 30mins, 60mins, 90mins, 2hours, 3hours, 4hours, 8hours
time interval (continuous): 5mins
range: adult: systolic blood pressure: 40~280mmhg
diastolic blood pressure: 10~220mmhg
mean pressure: 20~240mmhg
child: systolic blood pressure: 40~220mmhg
diastolic blood pressure: 10~160mmhg
mean pressure: 20~170mmhg
neonate: systolic blood pressure: 40~135mmhg
diastolic blood pressure: 10~100mmhg
mean pressure: 20~110mmhg
static pressure range: 0~300mmhg, static pressure accuracy: 3mmhg
maximum average deviation: 3mmhg; maximum standard deviation: 6mmhg
over-pressure protection: 300 mmhg (adult), 240 mmhg (child), 150 mmhg (neonate)
spo₂
range: 0~100%
resolution: 1%
accuracy: 1% (70~100%), 2% (40%~69%), not defined (.