Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Non Chemical Water Treatment Plant

Listing ID #911372

  • Supply Type Manufacturer, Exporter, Supplier
Preferred Buyer From : All over the world

We manufacture and supply a comprehensive assortment of Non Chemical Water Treatment Plant. Non Chemical Water Treatment Plant comes in different sizes and flanges as per the requirements of the....
View More Details
Send Enquiry
  • Member Since 12 Years
  • Nature of Business Retailer

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

We manufacture and supply a comprehensive assortment of Non Chemical Water Treatment Plant. Non Chemical Water Treatment Plant comes in different sizes and flanges as per the requirements of the customers. Non Chemical Water Treatment Plant supplies water continuously and is eco-friendly. It is low in maintenance, with less power consumption and comes with a warranty of 5 years.

 

Specifications Of SCALE OFF - On Line Scale Prevention System

The unit is a non-chemical on-line type scale Preventor not requiring any chemicals.

  • Non-chemical water treatment system prevents the formation of hard scale in cooling circuits of air conditioning equipment.
  • It works with a combination of principles of Adsorption, and Turbulence.
  • The inner core converts the hardness salts into colloidal particles.
  • The unit does not require any electricity or any other source of energy.
  • The unit should not have any recurring, operating and maintenance cost.
  • The size of the unit is determined based on the water quality and water flow rate.
  • The unit is installed in the condenser water circuit.
  • The outer casing is of stainless steel.
  • The company have method of checking the performance of system through computer simulation
  • The unit is backed by 5 year replacement warranty and one year after sales service

 

Selection Procedure :

  • Each model of Scale off works on a defined range of flow rate
  • Each model of Scale off works on a defined range of flow rate
  • In order to select the model flow rate at the tapping of condenser should be known or this can be calculated on the basis of 3-4 USGPM per ton
  • In the table below minimum flow rate is mentioned against each model while maximum flow rate of a model becomes the minimum flow rate of the next higher model

 

Advantages :

SCALE OFF possesses many advantages over conventional water treatment systems, some of which include :-

  • As SCALE OFF has no moving parts, it requires no replacement of spares or extra maintenance other than normal plant maintenance.
  • Maintenance Free : As the equipment is installed on – line of the cooling circuit
  • Eliminate Recurring Costs of Expensive Chemicals / Resins : SCALE OFF has no recurring costs associated with chemical dosing or water softening, as no chemicals, regenerative salts or resins are used.
  • No Energy Consumption for running of the equipment : Unlike conventional water treatment SCALE OFF doesn’t require any power or electrical inputs
  • Saves in Energy Consumption of the plant : Scale reduces heat transfer efficiency resulting in increased energy consumption, which can rise by almost 50%. As SCALE OFF is constantly preventing the deposition of Scale, thereby saving valuable energy cost
  • No Corrosion Risk : Water softeners necessitate the use of corrosion inhibitors, as the water tends to be corrosive. SCALE OFF on the other hand has this unique advantage of preventing scale without increasing the risk of corrosion.
  • No Pollution : Chemical dosing and water softening system require the use of chemicals, which are hazardous and cause pollution. Disposal of such hazardous chemicals in the environment is also a difficult task faced by customers.
  • Low Payback Period and Saving of Operational Cost : The pricing of SCALE OFF ensures that the user of the systems derives a payback period of three months to one year. This is made possible by savings in operating cost as compared to the fixed investment required.


Details

Factors Water Softner Scale Off
Composition of Water It reduces the pH of water thereby making it more corrosive in nature. The water remains neutral only the physical properties changes.
Recurring Cost Heavy monthly expenses in procurement, inventory, storage, handling and supervision of chemicals and salts to be dozed. No Recurring Cost
Prevention of Scale Water softener is designed for a particular hardness level (max 600 ppm) Prevents scale formation and removes existing scales from pipelines and condenser tubes. It has treated water hardness upto 3000 ppm.
Maintenance Special manpower required for regeneration of resins and operation. No man power required as SCALE OFF is an online equipment.
Man Power Requires extra manpower for monitoring and dosing of chemicals. No man power required as SG is an online equipment
Energy Consumption Energy Consumption No energy required for operation thus saves the electricity bill.
Pollution Disposal of untreated Brine water is a major problem. No pollution
Inventory Space for softener is required No space is required as it is installed online. In the pipe line after the pump and before condenser
Pay back Adds on recurring cost per year. Depending on water hardness payback period can be from 3 months to 1 year

 

Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Non Chemical Water Treatment Plant?

Quantity
Seller Contact Details
  • Seller Weldon Engineers (india)
  • Address Hari Nagar, Delhi

Find similar products

View all

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
Non Chemical Water Treatment Plant at Best Price in Delhi - ID: 911372
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Non Chemical Water Treatment Plant

Listing ID #911372

  • Supply Type Manufacturer, Exporter, Supplier
Preferred Buyer From : All over the world

We manufacture and supply a comprehensive assortment of Non Chemical Water Treatment Plant. Non Chemical Water Treatment Plant comes in different sizes and flanges as per the requirements of the....
View More Details
Send Enquiry

Company Information

  • Member Since 12 Years
  • Nature of Business Retailer

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

We manufacture and supply a comprehensive assortment of Non Chemical Water Treatment Plant. Non Chemical Water Treatment Plant comes in different sizes and flanges as per the requirements of the customers. Non Chemical Water Treatment Plant supplies water continuously and is eco-friendly. It is low in maintenance, with less power consumption and comes with a warranty of 5 years.

 

Specifications Of SCALE OFF - On Line Scale Prevention System

The unit is a non-chemical on-line type scale Preventor not requiring any chemicals.

  • Non-chemical water treatment system prevents the formation of hard scale in cooling circuits of air conditioning equipment.
  • It works with a combination of principles of Adsorption, and Turbulence.
  • The inner core converts the hardness salts into colloidal particles.
  • The unit does not require any electricity or any other source of energy.
  • The unit should not have any recurring, operating and maintenance cost.
  • The size of the unit is determined based on the water quality and water flow rate.
  • The unit is installed in the condenser water circuit.
  • The outer casing is of stainless steel.
  • The company have method of checking the performance of system through computer simulation
  • The unit is backed by 5 year replacement warranty and one year after sales service

 

Selection Procedure :

  • Each model of Scale off works on a defined range of flow rate
  • Each model of Scale off works on a defined range of flow rate
  • In order to select the model flow rate at the tapping of condenser should be known or this can be calculated on the basis of 3-4 USGPM per ton
  • In the table below minimum flow rate is mentioned against each model while maximum flow rate of a model becomes the minimum flow rate of the next higher model

 

Advantages :

SCALE OFF possesses many advantages over conventional water treatment systems, some of which include :-

  • As SCALE OFF has no moving parts, it requires no replacement of spares or extra maintenance other than normal plant maintenance.
  • Maintenance Free : As the equipment is installed on – line of the cooling circuit
  • Eliminate Recurring Costs of Expensive Chemicals / Resins : SCALE OFF has no recurring costs associated with chemical dosing or water softening, as no chemicals, regenerative salts or resins are used.
  • No Energy Consumption for running of the equipment : Unlike conventional water treatment SCALE OFF doesn’t require any power or electrical inputs
  • Saves in Energy Consumption of the plant : Scale reduces heat transfer efficiency resulting in increased energy consumption, which can rise by almost 50%. As SCALE OFF is constantly preventing the deposition of Scale, thereby saving valuable energy cost
  • No Corrosion Risk : Water softeners necessitate the use of corrosion inhibitors, as the water tends to be corrosive. SCALE OFF on the other hand has this unique advantage of preventing scale without increasing the risk of corrosion.
  • No Pollution : Chemical dosing and water softening system require the use of chemicals, which are hazardous and cause pollution. Disposal of such hazardous chemicals in the environment is also a difficult task faced by customers.
  • Low Payback Period and Saving of Operational Cost : The pricing of SCALE OFF ensures that the user of the systems derives a payback period of three months to one year. This is made possible by savings in operating cost as compared to the fixed investment required.


Details

Factors Water Softner Scale Off
Composition of Water It reduces the pH of water thereby making it more corrosive in nature. The water remains neutral only the physical properties changes.
Recurring Cost Heavy monthly expenses in procurement, inventory, storage, handling and supervision of chemicals and salts to be dozed. No Recurring Cost
Prevention of Scale Water softener is designed for a particular hardness level (max 600 ppm) Prevents scale formation and removes existing scales from pipelines and condenser tubes. It has treated water hardness upto 3000 ppm.
Maintenance Special manpower required for regeneration of resins and operation. No man power required as SCALE OFF is an online equipment.
Man Power Requires extra manpower for monitoring and dosing of chemicals. No man power required as SG is an online equipment
Energy Consumption Energy Consumption No energy required for operation thus saves the electricity bill.
Pollution Disposal of untreated Brine water is a major problem. No pollution
Inventory Space for softener is required No space is required as it is installed online. In the pipe line after the pump and before condenser
Pay back Adds on recurring cost per year. Depending on water hardness payback period can be from 3 months to 1 year

 

Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Non Chemical Water Treatment Plant?

Quantity
Seller Contact Details
  • Seller Weldon Engineers (india)
  • Address Hari Nagar, Delhi

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice