    Alloy Steel Non Polished Orifice Plate Flowmeter, For Gas Industries, Oil Industries, Petrochemical Industries

    • MaterialAlloy Steel, Mild Steel, Stainless Steel
    • FinishingNon Polished, Polished
    • CertificationYes
    • Packaging TypeCorrugated Box, Plastic Bags
    • Supply TypeManufacturer, Exporter, Supplier, Retailer, Distributor, Importer, Trader
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 14 Years
    • building Nature of Business Manufacturer
    • gst icon GST No. 07APKPS1463E1ZT

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • CertificationYes
    • ApplicationGas Industries, Oil Industries, Petrochemical Industries, Power Station, Sugar Industries
    • FinishingNon Polished, Polished
    • Packaging TypeCorrugated Box, Plastic Bags
    • Accuracy+/-1%
    • Line Size0-250NB, 25-500 NB, 500-1000 NB
    • Number Of FlowerOrifice Plate
    • MaterialAlloy Steel, Mild Steel, Stainless Steel

    Orifice Plate Flowmeter

    Series OP Orifice Plate Flowmeter

    The Series OP Orifice Plate Flowmeter is a complete orifice plate flow metering package. It incorporates a stainless steel orifice plate with a unique holder or carrier ring containing metering taps and integral gaskets. It was designed for use wherever there is an application for a conventional flow orifice plate. It can also be used in place of other primary differential producers for efficiency and cost effectiveness. Installation is accomplished simply by slipping the unit between standard flanges (orifice flanges are not required). The Series OP is available in line sizes from 1/2" to 24" and can be used with compatible liquids and gases.

    Features:

    Mounted with standard flanges

    Standard "corner tap" configuration

    Corrosion free material

    Simplified installation

    Built in metering taps (1/4" female NPT STD)

    Proven through a wide range of applications for accuracy and energy efficiency

    Assures long term reliability and accuracy

    Service : Compatible liquids and gases.

    Installation : Standard flange 125/150 rating.

    Pipe Requirements : General requirements 10 diameter upstream and 5 diameter downstream.

    Applications:

    Fluid flow rates in building water lines

    Boiler feedwater

    Cooling water

    Combustion or compressed air

    Steam flow

    Accuracy:

    The Series OP utilizes the corner tap proportions as defined in ISO 5167. While this code may not be referred to as International Standard until accepted by the ISO Council, the ASME Fluid Meters Research Committee has suggested that the dimensionless coefficient equation developed by the International Standards Organization (ISO) and presented in ISO 5167 is significantly better for the broad spectrum of flow measurement applications throughout process industries.

    The coefficient values used in the Series OP bore calculations represent the same confidence level assigned to the flange and radius taps widely accepted in fluid flow measurement.

    The accuracy assigned to the coefficient values is ±0.6% full scale flow for d/D (Beta) values 0.2 to 0.6 and ±0.7% for Beta values 0.7 to 0.75 (i.e. ß of 0.7 would have an uncertainty value of ±0.7% full scale flow).

    Accuracy of the differential signal produced by the Series OP equals or exceeds that of a properly manufactured and installed flange or radius tap orifice meter.

    Mounting:

    The orifice metering primary shall be suitable for installation between standard ANSI 125/150# flanges (any material) mounted on standard pipe (any material). The unit shall be "self centering" within the bolt circle of the flanges. No alignment of the orifice shall be necessary unless used with 300# or non-standard flange ratings. Drilling and or tapping of the main or flanges will not be allowed or required. The overall laying length shall be 1.25  including pre-attached ring type 1/8 ?? thick Buna "N" Gaskets.

    Pipe Requirements:

    Upstream and downstream pipe requirements are contingent upon two factors: (a) Beta Ratio-ratio of the orifice bore to the pipe I.D. (d/D); (b) The type of fitting or disturbance upstream of the Series OP. For most applications, 10 pipe dia. upstream & 5 dia. downstream are sufficient. (5 pipe dia. up and 2 dia. down are acceptable for non-critical application.)

    Type : Orifice Plate Flowmeter

    Material : Buna-N Gaskets.

    Accuracy : ±0.6% Full Scale Flow. (Beta= .2-.6) ±0.7% For Beta Greater Than .6.

    Application : Compatible Liquids And Gases.

    Certification : YES

     


    Additional Information

    • Payment Terms L/C, D/A, D/PT/T
    • Port of DispatchDelhi
    • Delivery Time4-6 week
    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry

    Product Images

    • Orifice Plate Flowmeter
    • Orifice Plate Flowmeter
    • Orifice Plate Flowmeter
    • Orifice Plate Flowmeter
    • Orifice Plate Flowmeter
    • Orifice Plate Flowmeter
    • Orifice Plate Flowmeter
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Orifice Plate Flowmeter?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice