Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Oil Gas IBR Steam Boilers

Listing ID #4097008

  • Supply Type Manufacturer, Exporter, Supplier
Preferred Buyer From : All over the world

Type : Three pass horizontal, smoke tube, fully wetback, packaged boiler, conforming to the latest revisions of Indian Boiler Regulations. (IBR) Capacity : 1000 to 25000 kg/h F & A100º C Working....
View More Details
Send Enquiry

Company Information

  • Member Since 6 Years
  • Nature of Business Retailer

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Type : Three pass horizontal, smoke tube, fully wetback, packaged boiler, conforming to the latest revisions of Indian Boiler Regulations. (IBR)
Capacity : 1000 to 25000 kg/h F & A100º C
Working Pressure: 10.54 / 14.5/ 17.5kg/cm2 (g) and above.
Fuel : LDO / FO / Gas / Dual Fuel (Oil cum Gas)
Thermal Efficiency : 88 ± 2 % without heat recovery unit and 92 ± 2 % with heat recovery unit based on NCV of fuel oil.
Burner : Fully automatic pressure jet (high - low / stepless modulation ); indigenous / imported burners.

The combustion chamber (furnace) forms the first pass in which the fuel is atomized, combusted and radiant heat transmitted to the water contained in the shell, submerging the furnace, reversing camber and smoke tubes. The hot flue gases are diverted through the internal reversing chamber (wetback) and subsequently to the second and third pass of tubes transferring the convective heat to the boiler.

The boiler is of Class 1 fusion-welded construction.

Burner & Boiler Controls

The burner programmer ensures an automatically controlled programme for start-up, firing, shutdown and restart of the boiler based on measurement of boiler pressure. Necessary interlocks are provided for safe operation.

The water level is controlled through Mobrey type dual controller which is a magnetically operated water level controller of vertical type in a float chamber and is externally mounted on the boiler. One switch of the dual controller operates the electric feed pump on/off. The second switch cuts out or locks out the burner in case of low level of water and at the same time operates a low level alarm.

The boiler is provided with one high pressure cutout switch and one additional pressure switch for high/low, or continuous modulation of operation.

Salient Features

MAXITHERM has adopted the modern concept of eccentrically located furnace with smoke tubes arranged in a staggered manner on one side of the furnace. The front and rear tubes and the furnace are accessible for inspection and maintenance. Generously proportioned furnace with large furnace volume ensuring;

  • Maximum possible absorption of radiant heat.
  • Avoidance of flame impeachment on the rear of the furnace.
  • Prevention of clinker formation.
  • Enhanced life of furnace.

Adequate water and steam spaces enable the boiler to meet fluctuating loads with out appreciable fall in the operating pressure. This also ensures prevention of priming, foaming and carryover of the boiler water into steam pipelines and further ensures steam with high dryness fraction.

The eccentrically located furnace has the following advantages :-

  • Easy accessibility to the outer surface of furnace for inspection and scale removal.
  • Possibility of providing single smoke box, which when opened makes all smoke tubes accessible for cleaning.

The burner is mounted directly in font of the furnace, facilitating opening of the front door to clean the tubes without disturbing the burner.



Company Details close-icon

Maxima Boilers Pvt. Ltd. was established in 1984 and incorporated as a Private Limited Company with its manufacturing facility at Rabale, Navi Mumbai.
A group of professionally qualified engineers having long years of experience in designing, manufacturing and marketing contributed in bringing out world class steam boilers, thermic fluid heaters, water heaters and hot air generators of different types and suitable for a variety of fuels and combinations of fuels.
MAXIMA launched a Group company namely MAXITHERM in the year 1992 and established a new works at Rabale, NAVI Mumbai. The capacity of production has increased considerably since then.
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Oil Gas IBR Steam Boilers?

Quantity
Seller Contact Details
  • Seller Maxima Group
  • Address Mulund, Mumbai, Maharashtra

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
Oil Gas IBR Steam Boilers at Best Price in Mumbai - ID: 4097008 | Maxima Group
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Oil Gas IBR Steam Boilers

Listing ID #4097008

  • Supply Type Manufacturer, Exporter, Supplier
Preferred Buyer From : All over the world

Type : Three pass horizontal, smoke tube, fully wetback, packaged boiler, conforming to the latest revisions of Indian Boiler Regulations. (IBR) Capacity : 1000 to 25000 kg/h F & A100º C Working....
View More Details
Send Enquiry

Company Information

  • Member Since 6 Years
  • Nature of Business Retailer

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Type : Three pass horizontal, smoke tube, fully wetback, packaged boiler, conforming to the latest revisions of Indian Boiler Regulations. (IBR)
Capacity : 1000 to 25000 kg/h F & A100º C
Working Pressure: 10.54 / 14.5/ 17.5kg/cm2 (g) and above.
Fuel : LDO / FO / Gas / Dual Fuel (Oil cum Gas)
Thermal Efficiency : 88 ± 2 % without heat recovery unit and 92 ± 2 % with heat recovery unit based on NCV of fuel oil.
Burner : Fully automatic pressure jet (high - low / stepless modulation ); indigenous / imported burners.

The combustion chamber (furnace) forms the first pass in which the fuel is atomized, combusted and radiant heat transmitted to the water contained in the shell, submerging the furnace, reversing camber and smoke tubes. The hot flue gases are diverted through the internal reversing chamber (wetback) and subsequently to the second and third pass of tubes transferring the convective heat to the boiler.

The boiler is of Class 1 fusion-welded construction.

Burner & Boiler Controls

The burner programmer ensures an automatically controlled programme for start-up, firing, shutdown and restart of the boiler based on measurement of boiler pressure. Necessary interlocks are provided for safe operation.

The water level is controlled through Mobrey type dual controller which is a magnetically operated water level controller of vertical type in a float chamber and is externally mounted on the boiler. One switch of the dual controller operates the electric feed pump on/off. The second switch cuts out or locks out the burner in case of low level of water and at the same time operates a low level alarm.

The boiler is provided with one high pressure cutout switch and one additional pressure switch for high/low, or continuous modulation of operation.

Salient Features

MAXITHERM has adopted the modern concept of eccentrically located furnace with smoke tubes arranged in a staggered manner on one side of the furnace. The front and rear tubes and the furnace are accessible for inspection and maintenance. Generously proportioned furnace with large furnace volume ensuring;

  • Maximum possible absorption of radiant heat.
  • Avoidance of flame impeachment on the rear of the furnace.
  • Prevention of clinker formation.
  • Enhanced life of furnace.

Adequate water and steam spaces enable the boiler to meet fluctuating loads with out appreciable fall in the operating pressure. This also ensures prevention of priming, foaming and carryover of the boiler water into steam pipelines and further ensures steam with high dryness fraction.

The eccentrically located furnace has the following advantages :-

  • Easy accessibility to the outer surface of furnace for inspection and scale removal.
  • Possibility of providing single smoke box, which when opened makes all smoke tubes accessible for cleaning.

The burner is mounted directly in font of the furnace, facilitating opening of the front door to clean the tubes without disturbing the burner.



Company Details close-icon

Maxima Boilers Pvt. Ltd. was established in 1984 and incorporated as a Private Limited Company with its manufacturing facility at Rabale, Navi Mumbai.
A group of professionally qualified engineers having long years of experience in designing, manufacturing and marketing contributed in bringing out world class steam boilers, thermic fluid heaters, water heaters and hot air generators of different types and suitable for a variety of fuels and combinations of fuels.
MAXIMA launched a Group company namely MAXITHERM in the year 1992 and established a new works at Rabale, NAVI Mumbai. The capacity of production has increased considerably since then.
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Oil Gas IBR Steam Boilers?

Quantity
Seller Contact Details
  • Seller Maxima Group
  • Address Mulund, Mumbai, Maharashtra

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice