    Patient Monitor, Weight : 2kg

    • Supply TypeManufacturer, Exporter, Supplier
    • Preferred Buyer Location All over the world

    We are offering mm-c004 modular type patient monitor. features : 6 standard parameters: ecg, resp, nibp, spo2, 2-temp, pr/hr, etco2, 2ibp and recorder, ag, bis, co, ob/gyn (toco,fhr, fm) are....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 18 Years
    • building Nature of Business Supplier
    • Year of Establishment 2001

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details

    Product Details no_img_icon

    We are offering mm-c004 modular type patient monitor. features :

    • 6 standard parameters: ecg, resp, nibp, spo2, 2-temp, pr/hr, etco2, 2ibp and recorder, ag, bis, co, ob/gyn (toco,fhr, fm) are optional
    • patient range: neonate, pediatric, and adult patients
    • touch screen 15"high resolution 1024 x 768 color tft lcd display
    • real time s-t segment analysis (15 types), drug calculation (15 types), pace-maker detection.
    • indication of incorrect manipulation and malfunction analysis.
    • patient info input management function
    • multi-lead ecg waveforms display in phase.
    • large volume of tabular and graphic trends information easy to recall.
    • capture dynamic waveforms.
    • efficient resistance to interference of defibrillator and hf knife.
    • up to 6 hours working capacity of built-in rechargeable 2 battery.
    performance specifications :display :
    • 15"color tft touch screen
    • rolling and refreshing waveform display
    • resolution: 1024x768
    • standard display
    • multi channels display
    trace :
    • 6 waveforms
    • sweep speed: 12.5mm/s, 25mm/s, 50mm/s
    indicator :
    • power/battery indicator light
    • qrs beep and alarm sound
    battery :
    • rechargeable lead acid cell, 12v/4ah
    • max.24 hours for charging, 3 hours for continuous working
    trend time :
    • above 256 hours
    alarm :
    • user-adjustable high , medium and low limits 3-level audible and visual alarm
    recorder :
    • built-in , thermal array
    • plethysmogram waveform: 2 channels
    • record mode: manual, on alarm, time-defined
    • recording width: 50mm
    • printing speed: 25mm/s
    • recording type: frozen waveform record
    • nibp recall record
    • trend table recordalarm record
    • fixed- time record
    ecg :
    • lead mode: 5 –leads (r,l,f,n,c)
    • lead selection: i,ii,iii,avr,avl,avf,v
    • waveform: 2 and 6 channel selectable
    • gain selection: 0.25mm/mv, 0.5mm/mv, 1 mm/mv, 2 mm/mv
    • sweep speed: 12.5mm/s;25mm/s;50mm/s
    • heart rate range: adult: 15~300bpm;neonate:/pediatric: 15~350bpm
    • accuracy: ±1bpm or ±1%, whichever is greater
    • resolution: 1bpm
    • filter: surgery mode :1~20hz
    • monitor mode: 0.5~40hz
    • diagnostic mode:0.05~130hz
    • scaling signal: 1mv, ±3%
    • protection: withstand 4000vac/50 voltage isolation
    • against electrosurgical interference and defibrillation
    • alarm range: 15~350bpm
    • s-t segment detection: measurement range:-2.0mv~ +2.0mv
    • alarm range: -2.0mv~ +2.0mv
    • accuracy: -0.8mv ~+0.8mv
    • error: ±0.02mv
    • arrhythmia analysis: yes. 15types
    nibp :
    • method: digital automatic oscillometric
    • operation mode: manual/automatic/continuous
    • auto measurement time: adjustable(1~480min)
    • measurement unit: mmhg/kpa selectable
    • measurement types: systolic, diastolic, mean
    • measurement range:
    • range of systolic pressure: adult: 40~270mmhg
    • pediatric:40~200mmhg
    • neonate: 40~135mmhg
    • range of mean pressure: adult: 20~235mmhg
    • pediatric:20~165mmhg
    • neonate: 20~110mmhg
    • range of diastolic pressure: adult: 10~215mmhg
    • pediatric:10~150mmhg
    • neonate: 10~100mmhg
    • over-pressure protection: double safety
    • protection resolution: 1mm hg
    • alarm: systolic, diastolic, mean
    spo2 :
    • measurement range: 0~100%
    • resolution: 1%
    • accuracy: ±2%(70-100%);0-69% unspecified
    • alarm range: 0~100%
    • pulse rate: range: 20~300bpm
    • solution: 1bpm
    • error: ±1bpm or ±2%, whichever is greater
    respiration :
    • method: thoracic impedance
    • measurement range: adult : 7~120rpm; neonate/pediatric: 7~150rpm
    • apnea alarm: yes, 10~40s
    • solution : 1rpm
    • accuracy: ±2rpm
    temperature :
    • compatible probe: ysi or cyf
    • measurement range: 0~50 c
    • resolution: 0.1 c
    • accuracy: ±0.1 c
    • channel: dual-channel, provide t1;t2,dt
    • refreshing time: about 1s
    • average measuring time: 70rmp)
    • respiration time:


    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Patient Monitor?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice