Contact SupplierWe are offering modular patient monitor.
l plugin modular design, all modules support hot plug with free combination, convenient to use, maintain and upgrade
2 professional eeg monitoring to make it more perfect
3151719 inch high definition color display
4 standard six-parameter module: ecg, hr, nibp, spo2, resp and temp
5 powerful software functions, to show full range of information reports
6 3 level intelligent alarms: sound, light and voice alert, volume adjustable
7 compatible with central monitoring system
8 optional modules: eegpsg, etco2, ibp, csi (cerebral state index);
9 expandable eeg or eeg&psg module for brain function and polysomngraphic recording:
10 independent eeg module is 81632 channels optional
11. Integrated eeg$psg module including: eeg(816 channels);eog (2 channels); emg (1 channel); snoring (1 channel ); airflow (1 channel ); abdominal (1 channel )
ecg
lead type: 35 leads electric cable
input: 3 leads: ra, la, ll (lead method: i, ii, iii)
13 leads: ra, la, ll, rl, v (lead method: i, ii, iii, avr, avl, avf, v)
gain: â´250, â´500, â´1000, â´2000
heart rate range: 15~300bpm (adult), 15~350bpm (child & neonate)
accuracy: â±1bpm or â±1%, whichever is bigger
resolution: 1bpm
sensitivity: >200uv (peak to peak)
input impedance: >5mï�
bandwidth: diagnosis model: 0.05~130hz, monitoring: 0.5~40hz, operation: 1~20hz
cmrr: diagnosis model: >90db, monitoring model: >100db, operation model: >100db
electrode polarization and voltage range: â±300mv
pacemaker impulses amplitude: â±2mv~ â±700mv, width: 0.1ms~2ms, rise time: 10us~100âµs
recovery time:
signal range: â±8 mv peak to peak
calibrate signal: 1mv peak to peak; accuracy: â±5%
st detection: range: -2.0mv~ +2.0mv, accuracy: -0.8 mv~ +0.8mv, error: â±0.02mvâ±10%
arrhythmia analysis (13 kinds):
nibp (noninvasive blood pressure)
method: pulse wave oscillation
operation mode: manualautomaticcontinuous
time interval (automatic): 1min, 2mins, 3mins, 4mins, 5mins, 10mins, 15mins, 30mins, 60mins, 90mins, 2hours, 3hours, 4hours, 8hours
time interval (continuous): 5mins
range: adult: systolic blood pressure: 40~280mmhg
diastolic blood pressure: 10~220mmhg
mean pressure: 20~240mmhg
child: systolic blood pressure: 40~220mmhg
diastolic blood pressure: 10~160mmhg
mean pressure: 20~170mmhg
neonate: systolic blood pressure: 40~135mmhg
diastolic blood pressure: 10~100mmhg
mean pressure: 20~110mmhg
static pressure range: 0~300mmhg, static pressure accuracy: â±3mmhg
maximum average deviation: â±3mmhg; maximum standard deviation: â±6mmhg
over-pressure protection: 300 mmhg (adult), 240 mmhg (child), 150 mmhg (neonate)
spo?
range: 0~100%
resolution: 1%
accuracy: â±1% (70~100%), â±2% (40%~69%), not defined.