    • DisplaySuper bright in 4 + 4 format , with NO BLINK programming technique Upper 4 digits 0.5" red colour Lower 4 digits 0.39" green colour
    • PROFILER2 Profile Programmes / 8 Segments Each Each segment programmable for either RAMP or SOAK Profiler can be configured as : - RAMP/SOAK - RAMP/RAMP - SOAK/SOAK - SOAK/COOL Soak Time programmable in HH-MM , MM-SEC Overshoot control during
    • CommunicationRS485, 2-Wire, Half duplex RS485 MODBUS on request, MODBUS RTU or ASCII Baud Rate Programmable 1200/2400/4800/9600, contact factory for higher Baud Rates
    • Retransmission4-20 mA or 20-4 mA or 0-20 mA or 20-0 mA programmable, Non-isolated, Retransmission assign for O/P 2 and O/P 3 Provided on request
    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 8 Years
    • building Nature of Business Retailer

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • DisplaySuper bright in 4 + 4 format , with NO BLINK programming technique Upper 4 digits 0.5" red colour Lower 4 digits 0.39" green colour
    • AmbientCompensation automatic, ambient 0-60°C
    • Ananciation L.E.D's7 L.E.D.'s , 3 mm , multi colour, 3 for O/P's, 1 each for A/M, Alarm, Profile, Soak Time
    • Control ModesHeat / Cool / Heat-Cool
    • Overshoot ControlProvided
    • OutputsTHREE, Programmable outputs with modular attachments Relay module SSR module 4-20 mA module Retransmission module
    • Soak TimerAssigned for O/P 2 or O/P 3, Soak Timer programmable (HH-MM or MM-SEC) Set Point Start up or Power on start up
    • ALARMSAssigned for O/P2 and O/P3 Alarm Types : Low / High /Band /Deviation / End of Profile Alarm Acknowledge : Latchable / Unlatchable Alarm Inhibit : Available
    • Retransmission4-20 mA or 20-4 mA or 0-20 mA or 20-0 mA programmable, Non-isolated, Retransmission assign for O/P 2 and O/P 3 Provided on request
    • Control Action AssignPID for O/P 1 and O/P 2 ON-OFF for O/P 1, O/P 2 , O/P 3 T/P for O/P 1, O/P 2 , O/P 3
    • RangeRefer 'table A''
    • Manual OutputProvided, 0 to 100%
    • CommunicationRS485, 2-Wire, Half duplex RS485 MODBUS on request, MODBUS RTU or ASCII Baud Rate Programmable 1200/2400/4800/9600, contact factory for higher Baud Rates
    • Parameter SettingBy soft touch, Elegant, Sturdy membrane keys & User friendly menu driven software
    • NoteOutput modules are predefined All three outputs can be assigned as relay or SSR or 4-20 mA, this means at a time either 3 relays or 3 SSR's or 3 4-20 mAs outputs also available
    • InputONE UNIVERSAL Input Thermocouples : J,K,T,R,S RTD's : PT-100, PT-1000 DC mA : 0 – 20 mA, 4 – 20 mA (Maximum 12 Volts) DC mV : ± 50 mV, ± 100 mV, ± 200 mV, ± 250 mV DC Volts : ± 1V, ± 3.3V, ± 5V, ± 10V
    • CONTROLS 
    • Resolution1 or 0.1 or .01 or .001 programmable
    • Control ActionPID / On-OFF / TP PID P = Propotional Band = 1.0 to 999.9 units adjustable I = Integral = 0 to 3600 ( 0-1200) seconds adjustable D = Derivative = 0 to 500 seconds adjustable CT = Cycle Time = 0.5 to100 seconds adjustable On-OFF Hys
    • INPUT Control Outputs RatingRelay SPST 230V / 3 Amp, 12 volts DC pulses for , 4-20 mA (Load 450 ohms)
    • PROFILER2 Profile Programmes / 8 Segments Each Each segment programmable for either RAMP or SOAK Profiler can be configured as : - RAMP/SOAK - RAMP/RAMP - SOAK/SOAK - SOAK/COOL Soak Time programmable in HH-MM , MM-SEC Overshoot control during

    Anupam's introduces state of art, truly universal, powerful PID controller with inhouse design. The PID2020 series is developed with state of art microcontroller. The robust hardware and software makes the controller very useful in noisy industrial environment. The PID2020 finds applications in Industrial Ovens, Muffle Furnaces, B.O.D. Incubators, Humidity Chambers, Environmental Chambers, Sterlizers, Blood Bank Equipments, Constant Temperature Baths, Packaging, Plastic Moulding, Thyristors Heat Controllers, Motor Controllers, Controlled Melting, Valve Control...etc.

    Features
    • Initializing the controller integral to a desired value
    • Increasing the setpoint in a suitable ramp
    • Disabling the integral function until the PV has entered the controllable region
    • Limiting the time period over which the integral error is calculated
    • Preventing the integral term from accumulating above or below pre-determined bounds.


    INPUTSENSORRANGEACCURACY
    R.T.D.PT-100-200 to 600°C± 1°C
    PT-10000 to 500°C± 1°C
    THERMOCOUPLESChromel/Alumel (K)0 to 1300°C± 1°C
    Iron - Constantan (J)0 to 750°C± 1°C
    Copper-Constantan (T)-200 to 350°C± 1°C
    Pt / Rh (R or S)0 to 1700°C± 1°C
    D.C. LINEAR INPUTS4 to 20 mA / 0 to 20 mAUser Programmable± Least count
    ± 50 mV, ± 100 mV,User Programmable± Least count
    ± 200 mV, ± 250 mV
    ± 1V, ± 3.3V,User Programmable± Least count
    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for PID Controllers?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice