Contact SupplierThe KRD12 series shock test system is used to measure and determine the horizontal impact resistance of a product or package, and to evaluate the reliability and structural integrity of the test unit in a horizontal impact environment. The system can perform conventional half-sine wave, post-peak sawtooth wave, or square wave shock test to realize the shock energy that the product is subjected to in the actual environment, thereby improving the product or packaging structure. Windows-based stable control system, full-automatic remote-control interface Pneumatic cylinder driving with advantages of large driving force, short accelerating stroke, low cost and pollution free. Trapezoidal guide posts: large supporting force, good lubricity and full-automatic positioning table. Automatic control of shock speed: the shock overload value is achieved by adjusting the air pressure. After the cylinder pressure is set, system will automatically control the shock speed with high accuracy and good repeatability. Adopts the high strength and hardness cast aluminum table, which has high first-order resonance frequency, featured with low noise and no clutter The most reliable double-brake system: effectively avoids secondary rebound collisions, more securely positioning the table, and more reliably guarantees the safety of the operator. Multiple waveforms: can perform conventional half-sine waves, post-peak sawtooth waves, or square waves. Easy installation: the device comes with a base, due to short driving stroke of the pneumatic cylinder, the footprint is small.
Model Parameters | KRD12-10 | KRD12-50 | KRD12-100 | KRD12-200 | KRD12-500 | KRD12-1000 | KRD12-2000 | KRD12-3000 | ||
Rated Load (kg) | 10 | 50 | 100 | 200 | 500 | 1000 | 2000 | 3000 | ||
Table Size (mm) | 200×200 | 500×500 | 600×600 | 800×800 | 1000×1000 | 1200×1200 | 1500×1500 | 2000×2000 | ||
Peak Acc. (g)
| Half-Sine | 10-5k | 10~1.5k | 10~1k | 10-800 | 10-600 | 10-500 | 10-200 | 10-150 | |
Post-Peak Sawtooth | 10~200 | 10~100 | 10~50 | |||||||
Trapezoid | / | 15~200 | 15~200 | 15-100 | 15-60 | 15-60 | 15-50 | 30-50 | ||
Pulse Duration (ms) | Half-Sine | 0.3~40 | 1~60 | 1.5~60 | 2~60 | 2.5~60 | 3~60 | 6~60 | 8~60 | |
Post-Peak Sawtooth | 3~18 | 6~18 | ||||||||
Trapezoid | / | 3~18 | 6~18 | |||||||
Bump Waveform | Half sine wave | |||||||||
Bump Peak Acceleration (g) | 4-150 | 5-100 | ||||||||
Bump Pulse Duration (ms) | 2-30 | 3-30 | ||||||||
Bump Rate (Times/Min) | 10-120 | |||||||||
Overall Dimension (mm) | 3000×1150×850 | 3300×1150×850 | 3500×1200×850 | 3800×1300×850 | 4000×1450×850 | 4500×1650×850 | 5500×2000×850 | 6000×2200×850 | ||
Weight (kg) | 2000 | 2500 | 3000 | 4000 | 4500 | 5000 | 6000 | 7500 | ||
Installation Condition | Environment | Temperature range 0 ~ 40℃; Humidity ≤ 80%, non-condense | ||||||||
Power | AC220V±10%, 50Hz | |||||||||
Air source | ≤1MPa | |||||||||
Floor | Foundation-free, the cement floor shall be leveled and the working distance of 800 ~ 1000mm shall be reserved around the equipment | |||||||||
Standard | MIL-STD-810F IEC68-2-27 UN38.3 IEC62281 IEC62133-2 UL2054 IEEE1625 SAEJ2929 IEC62660-2 ISO12405-3 UL2580 | |||||||||