Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Polypropylene Fume Hood

Listing ID #4668605

  • Supply Type Manufacturer, Exporter, Supplier
Preferred Buyer From : All over the world

Polypropylene Fume Hood for high acid and trace metal analysis use. WEIBER offers a range of Pp Fume Hood constructed from all white stress-relieved, acid resistant, non-corrosive polypropylene.....
View More Details
Send Inquiry
Netaji Subhash Place, Delhi
View Number
  • Member Since 12 Years
  • Nature of Business Retailer

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Polypropylene Fume Hood for high acid and trace metal analysis use. WEIBER offers a range of Pp Fume Hood constructed from all white stress-relieved, acid resistant, non-corrosive polypropylene. These hoods are specially engineered for use with harsh corrosive acids. They are available as conventional total exhaust hoods providing only operator protection, and as HEPA-filtered laminar flow fume hoods providing both operator and product protection.

Constructed almost entirely of polypropylene, this fume hood contains the Zero Leak Airflow System, available only from. The system prevents uneven particulate loading by eliminating direct blasts to the HEPA filter, dispensing air over 100% of the surface. These cabinets meet Federal Standard 209e, Class 10 air quality conditions, and have been independently tested for containment properties in accordance to ASHRAE Standard 110-1995 for Fume Hoods.

  • Microprocessor based controls
  • Manufactured from all-white, structural polypropylene.
  • Conventional total exhaust hoods are suitable for applications with harsh corrosive acids which regular steel hoods may not withstand.
  • A microprocessor controller monitors face velocity and displays the real-time airflow on the LCD screen in linear feet per minute.
  • Have an advanced airfoil design that is important to the overall safety and performance of the fume hood.
  • A removable work surface exposes a spill basin that may be fitted with a drain for disposal of any spills.
  • Built-in vapor-proof fluorescent light
  • Easy-access utilities panel for operation and maintenance
  • Flame-retardant polypropylene interior - higher temperature working range than fiberglass.
  • HEPA-filtered laminar flow fume hoods are suitable for use with trace metal applications. These units incorporate a top located filtration system powered by a dynamically balanced motorized impeller for even air distribution and excellent energy efficiency resulting in quiet operation.
  • Available with a wide range of options and accessories, including, service fixtures, sinks, electrical outlets, digital airflow alarms and base cabinetry.
  • Corrosion resistant interiors and exteriors.


Working dimensions (WXDXH)mm Weight kg
1232*914*1718 320
1537*914*1718 332
1842*914*1718 375
2451*914*1718 575
Exterior and interior construction Structural polypropylene
Exhaust 500 cFM-1250cFM
Static exhaust 20mm-38mm
Exhaust duct 102*610 mm
Power requirements 230V, 50 Hz
Down Flow Velocity 105 LFPM 60 LFPM (0.30 m/s)
Inflow Velocity 105 LFPM (0.53 m/s)
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Polypropylene Fume Hood?

Quantity
Seller Contact Details
  • Seller Acmas Technocracy Private Limited
  • Address Netaji Subhash Place, Delhi

Find similar products

View all

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
Polypropylene Fume Hood at Best Price in Delhi - ID: 4668605 | Acmas Technocracy Private Limited
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Polypropylene Fume Hood

Listing ID #4668605

  • Supply Type Manufacturer, Exporter, Supplier
Preferred Buyer From : All over the world

Polypropylene Fume Hood for high acid and trace metal analysis use. WEIBER offers a range of Pp Fume Hood constructed from all white stress-relieved, acid resistant, non-corrosive polypropylene.....
View More Details
Send Enquiry

Company Information

  • Member Since 12 Years
  • Nature of Business Retailer

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Polypropylene Fume Hood for high acid and trace metal analysis use. WEIBER offers a range of Pp Fume Hood constructed from all white stress-relieved, acid resistant, non-corrosive polypropylene. These hoods are specially engineered for use with harsh corrosive acids. They are available as conventional total exhaust hoods providing only operator protection, and as HEPA-filtered laminar flow fume hoods providing both operator and product protection.

Constructed almost entirely of polypropylene, this fume hood contains the Zero Leak Airflow System, available only from. The system prevents uneven particulate loading by eliminating direct blasts to the HEPA filter, dispensing air over 100% of the surface. These cabinets meet Federal Standard 209e, Class 10 air quality conditions, and have been independently tested for containment properties in accordance to ASHRAE Standard 110-1995 for Fume Hoods.

  • Microprocessor based controls
  • Manufactured from all-white, structural polypropylene.
  • Conventional total exhaust hoods are suitable for applications with harsh corrosive acids which regular steel hoods may not withstand.
  • A microprocessor controller monitors face velocity and displays the real-time airflow on the LCD screen in linear feet per minute.
  • Have an advanced airfoil design that is important to the overall safety and performance of the fume hood.
  • A removable work surface exposes a spill basin that may be fitted with a drain for disposal of any spills.
  • Built-in vapor-proof fluorescent light
  • Easy-access utilities panel for operation and maintenance
  • Flame-retardant polypropylene interior - higher temperature working range than fiberglass.
  • HEPA-filtered laminar flow fume hoods are suitable for use with trace metal applications. These units incorporate a top located filtration system powered by a dynamically balanced motorized impeller for even air distribution and excellent energy efficiency resulting in quiet operation.
  • Available with a wide range of options and accessories, including, service fixtures, sinks, electrical outlets, digital airflow alarms and base cabinetry.
  • Corrosion resistant interiors and exteriors.


Working dimensions (WXDXH)mm Weight kg
1232*914*1718 320
1537*914*1718 332
1842*914*1718 375
2451*914*1718 575
Exterior and interior construction Structural polypropylene
Exhaust 500 cFM-1250cFM
Static exhaust 20mm-38mm
Exhaust duct 102*610 mm
Power requirements 230V, 50 Hz
Down Flow Velocity 105 LFPM 60 LFPM (0.30 m/s)
Inflow Velocity 105 LFPM (0.53 m/s)
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Polypropylene Fume Hood?

Quantity
Seller Contact Details
  • Seller Acmas Technocracy Private Limited
  • Address Netaji Subhash Place, Delhi

Find similar products

View all products in Fume Hood

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice