Battery Type/Lifeafter 20 minutes of non-use (can be disabled)
Environment0 to 50°C (32 to 122°F); RH max 100%
pH Input impedence10¹² Ohms
pH CalibrationAutomatic, at one or two points with three standard buffers (4.01, 7.01,10.01)
Temperature Accuracy±0.4°C; ±0.8°F
Temperature ProbeHI7662 stainless steel temperature probe with 1 m (3.3’) cable (included)
Temperature Resolution0.1°C / 0.1°F
mV Range±699.9 mV; ±1999 mV
mV Resolution0.1 mV; 1 mV
Dimensions180 g (6.3oz.)
Temperature CompensationAutomatic from -20.0 to 120.0ºC (-4.0 to 248.0ºF) or manual without temperature probe connected
Temperature Range-20.0 to 120.0°C / -4.0 to 248.0°F
Dimensions164 x 76 x 45 mm (6.5 x 3.0 x 1.8”)
Automatic Shut-Offafter 20 minutes of non-use (can be disabled)
pH Accuracy±0.01 pH
pH ElectrodeHI1230B PEI body pH probe with BNC connector and 1 m (3.3’) cable (included)
Details
The HI8424 is an economical portable pH/ mV meter. This meter uses a BNC connector for the pH electrode input allowing for a wide selection of pH and ORP electrodes to be used. A separate temperature probe is supplied to provide temperature compensated pH measurement. The HI8424 is very basic in operation with automatic calibration to one or two points to any of the three programmed buffer values (pH 4.01, 7.01, and 10.01). The simplicity in operation and the economical price point has made the HI8424 one of the most popular meters available in the market.
Ordering Information - HI8424 is supplied with HI1230B pH electrode, HI7662 temperature probe, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI700601 electrode cleaning solution sachets (2), battery, protective case and instructions.
Features at-a-glance
Waterproof - Compact, heavy duty casing that is protected against any ingress of water that would damage the electronics.
Automatic Calibration - calibration to one or two points to any of the three programmed buffer values (pH 4.01, 7.01, and 10.01).
Automatic Temperature Compensation - Separate temperature probe is supplied to provide temperature compensated measurements.
High Resolution/Accuracy mV Range - The HI8424 automatically switches resolution from 1 mV to 0.1 mV when ORP readings are between -699.9 to +699.9 mV. The accuracy within this range is ±0.2 mV.
Automatic Shutoff - The automatic shutoff feature will turn the meter off after 20 minutes to conserve battery life.
Low Battery Indicator - A low battery indicator will be displayed when the battery life is almost exhausted (5% remaining) alerting the user that a new battery will be needed in the near future.
Interested in this product? Ask for more details & Latest Price from seller