Company Information
Ask for more detail from the seller
Contact Supplierinstallation and service industries.
The detector relies on the property of halogenated gases to reduce the current produced in a corona discharge at the sensor. The current change is detected and presented as an increase in frequency of an audible alarm. The higher the frequency, the greater the concentration of halogen detected.The unit is supplied complete with its own battery supply and requires no other electrical or gas services. Also supplied with the equipment is a check leak which will test the sensitivity ofthe equipment in service. The instrument is ready for use immediately it is switched on and will not be adversely affected by large concentrations of halogenated gases in the atmosphere.
Main Advantages
● Rapid Response
● Audio Output
● No warm-up time
● Battery Operated
● Lightweight
● Built-in Test Leak
● Detects a leak of less than 1/10 oz per year
● Completely new design sensortip insensitive to draughts
Technical Specifications
Sensitivity: Better than 1/10th oz per year R12
Response Time: 0.1 second
Specification: 356 x 75 x 89 mm
Battery Life: 30 hours normal use
Duty Cycle: Continuous Operating
Temperature: 0 to 40°C
Check Leak: Normally /2 oz/year (14 gm/year)
Probe Length: 240 mm
Weight: 305 gm (10.7 oz) containing batteryand spares supplied
Packaging: Instrument supplied in PVC pouch, packed with spares in cardboard box with space available for accessory box.