    Features : Front button for resetting in manual mode External potential free (zero volt /no voltage) terminal contacts for auto mode. LED indication for relay status Window displays the type of....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 11 Years
    • building Nature of Business Manufacturer
    • Year of Establishment 1995

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    Features :

    • Front button for resetting in manual mode
    • External potential free (zero volt /no voltage) terminal contacts for auto mode.
    • LED indication for relay status
    • Window displays the type of fault that has occurred during unhealthy condition
    • Trip delay time and limits for each parameter can be set digitally
    • All programs can be locked by removing short link across specified terminals
    • Unwanted parameters can be by-passed as per user's choice.
    • Relay can be configured to have NO or NC status during healthy condition
    • Unit will retain fault till accepted in manual mode
    • PVMD, PVMD-G : Monitors and trips the circuit after the set trip delay time when ever power unhealthiness (phase failure, phase sequence, phase unbalance under voltage or over voltage) occurs.
    • Displays all the 3 phase voltages in a scrolling fashion during healthy condition.
    • PVMD – Panel / Flush mounting, PVMD-G Din Rail mounting
    • PVIMD, PVIMD-G : Monitors and trips the circuit after the set trip delay time when ever power unhealthiness (phase failure, phase sequence, phase unbalance under voltage, over voltage, under current or over current)
    • Displays all the 3 phase voltages and 3 phase currents in a scrolling fashion during healthy condition.
    • User can program nominal current. Under current and over current limits can be set in percentage with reference to nominal current.
    • User can set the in-rush time delay.
    • Terminals to connect all the 3 phase CTs are provided.
    • CT primary can be programmed up to 500 in steps of 5. CT secondary will be factory set for 5
    • PVIMD – Panel / Flush mounting. PVIMD-G - Din Rail mounting
    • Din sized enclosure with Auto / manual Switch


    Dimensions :

    • Overall : PVMD, PVIMD– 96 x 96 x 97.5mm, PVMD-G, PVIMD-G,– 76 x 78 x 115mm (W x H x D)
    • Cut-out : PVMD, PVIMD– 92 x 92mm (W x H)


    Applications : Any 3 phase 4wire systems like Motors, pumps, generators, Distribution panels, MCC, air conditioners, elevators, cranes, escalators


    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Power Monitoring Device?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice