Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    Pressure Reducing Valves

    • ApplicationTypically Used At Outlet Of Hydropneumatic System For Maintaining Specific Pressure Ranges.
    • Number Of FlowerPressure Reducing Valve
    • Setting/Checking Pressure ProcedureDetailed Steps Provided For Setting/checking Pressure With A Pressure Gauge
    • Pressure Gauge Specifications¼' BSP End Connection, 50mm Dial, Ideally Back Mounted
    • Supply TypeExporter, Distributor
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 7 Years
    • building Nature of Business Supplier
    • gst icon GST No. 27AFXPS8829P1ZW

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • Number Of FlowerPressure Reducing Valve
    • ApplicationTypically Used At Outlet Of Hydropneumatic System For Maintaining Specific Pressure Ranges.
    • Ideal ApplicationSupplying Water To Higher Floors Or Where Low Output Pressure Is Required
    • Recommended Pressure Testing KitVarie Specialized Pressure Testing Kit With Built-in Air Release Arrangement
    • Pressure Gauge Specifications¼' BSP End Connection, 50mm Dial, Ideally Back Mounted
    • Outlet Pressure Range0.5 To 10 Kg/cm2
    • Special FeaturesForce Amplifier System For Sensitivity To Pressure, Uncompromised Flow Rate Even At Low Pressures
    • Setting/Checking Pressure ProcedureDetailed Steps Provided For Setting/checking Pressure With A Pressure Gauge

    VH The VH is similar in all feature to the W3 G but specially 
    designed for higher output pressure range (up to 10 kg/cm2) is required.
    Typically used at outlet of Hydropneumatic system where higher 
    pressures have to be kept to supply water to higher floors (approx 35 
    meters & above) and PRV cannot be installed at higher floor where 
    water will be drawn and thus has limitation of being installed at base 
    level near system only.
    VL The VL is similar in all 
    feature to the W3 G but specially designed for the low output pressure 
    range (0.5 to 2 kg/cm2). The force amplifier system used enhances 
    sensitivity to pressure and gives uncompromised flow rate even at low 
    pressures. Ideal where more than 4 branches are taken in a downtake line
    and lower branches will likely cross norm of 2.4 kg/cm2 pressure. 

    Setting Outlet Pressure
     
    Even
    if a PRV is calibrated for a certain outlet pressure from factory it is
    good practice to set & verify pressure at site with help of Varie 
    pressure testing kit* or a pressure gauge.
    For
    fast and efficient work the Varie specialized pressure testing kit is 
    recommended which has built-in arrangement for air release which helps 
    getting  correct readings and faster work.
    If the pressure testing kit is not used a simple pressure gauge with following specifications can be used:
     ¼' BSP end connection
     50mm dial
     Ideally back mounted but side mounted will also do. (PRV 40mm & 50mm needs side mounted only)
    Procedure of Setting / Checking Pressure with Pressure Gauge
     
     Close the shut off valve (Ball valve) installed before PRV.
     If not provided then close shut off valve installed at the
     Start of down take on terrace (Or uptake line in case of hydro pneumatic system).
     Open blanking plug with 'O' ring.
     Allow residual water in line to empty out through the open port.
     Thread-in
    the pressure gauge in the ¼" BSP threaded port. (Ensure few turns of 
    Teflon tape on thread of pressure gauge for sealing), Do not tighten 
    completely. (to ensure removal of air)
     
     Turn on supply by opening the shut-off valve before PRV.
     Allow some water to come out thru the threads of the pressure gauge (to ensure that air is removed).
     Tighten pressure gauge completely using a spanner.
     Ensure
    that 'no flow' of water is there on outlet, as pressure checking / 
    setting has always to be done in 'static' or 'no-flow' condition.
     
     T


    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Pressure Reducing Valves?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice