    Features: 30% air exhaust 70% air recirculation HEPA OR ULPA -filtered exhaust air in Type A2 cabinet may be recirculated into the room or exhausted to the outdoors through a canopy exhaust....
    View More Details
    Send Enquiry

    Company Information

    location Somwar Peth, Pune, Maharashtra
    4.5/5fill iconfill iconfill iconfill iconhalf icon(16)
    View Number
    • calendar Member Since 9 Years
    • building Nature of Business Trader
    • gst icon GST No. 27AABFJ1118P1ZA

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    Features:

    • 30% air exhaust
    • 70% air recirculation
    • HEPA OR ULPA -filtered exhaust air in Type A2 cabinet may be recirculated into the room or exhausted to the outdoors through a canopy exhaust connection.
    • HEPA OR ULPA -filtered downflow air is a portion of mixed downflow and inflow air from a common plenum.
    • Negative Pressure air surrounding all biological contaminated ducts and plenums.
    • Negative pressure surrounds the work area with double wall plenums for protection.
    • Air drawn through pre-filter is made to pass through highly effective HEPA OR ULPA (High Efficiency Particular Air) filters. The prefilter fitted extends the life of HEPA OR UPLA filter drastically. Fitted with HEPA OR ULPA Filter made from water resistant, fire retardant, imported micro fine glass fibre media; conforms to EU – 14 Grade, with an efficiency rating better than 99.999% for 0.3 μ.These filters are designed to accommodate higher air flow volume.
    • Prefilter are made from Non-Woven Synthetic with HDPE mesh and Al expanded mesh on air leaving side; conforms to EU – 4 / G-4 Grade, with an efficiency of down to 10 micron. These filters can be cleaned by compressed air & also washable.
    • Mounted on heavy tubular stand with lockable castors.
    • Aerodynamic airflow grills maintain safety and prevent blockage
    • U.V and fluorescent interlock available
    • Ergonomic and comfortable 10 degrees sloped front window for comfortable head and elbow rest position, thus reducing fatigue.
    • The sash is counterbalanced for smooth and lightweight operation with the standard opening of 200mm ±10 mm for easier access to work zone and enhanced user safety.

     

    Cass II Biosafety Cabinet Protection

    • High velocity air forced through HEPA filters.
    • Filtered air is thrown in the chamber through jet nozzles with a high velocity which in turn disperse particulate matter on all surface.
    • The lower portion of the Air showers suck the contaminated air and allow it to pass to blower supply plenum through pre-filter installed at the base.
    • This process is a continuous process in which air is continuously filtered and recirculated inside the chamber without any exchange with the external environment.

     

    Upper & Front Cover

    Removable upper and front cover simplifies filter, blower and front control panel replacements and maintenance easier.

     

    Material Of Construction

    Working Table is made up of Stainless Steel (SS-304). External Cabinet is fabricated of CRC sheet duly powder coated OR Stainless Steel (SS-304) (as ordered).

     

    Front Window/Sash

    Front Sash consists of a toughened transparent glass for a clear inside view. In addition it serves optimum resistance and protection from harmful UV rays, protects user from exposure to harmful Ultraviolet radiation.

     

    Drain Trough With Valve

    The trough at base is easy to clean and for offloading liquid spillage if any.

     

    Decontamination By UV Lamp

    UV Lamp to produce UV rays of 253.7 nanometers and fluorescent lamp are interlocked and motor blower are turned off/on as and when front sash is closed/opened. UV lamps functions through a timer (Option) to control the decontamination cycle and maximize UV lamp life. The UV lamp shuts off once the desired set time of decontamination is over and switches the fluorescent lamp to ON position.

     

    Electrical Utilities

    Splash proof sockets is provided for optimum convenience of using small electrical devices inside the cabinet. ON/OFF Switches for motor & Lights.

     

    Front Airflow Intake Grid

    Aerodynamically designed front airflow intake grid eliminates potential turbulence and contamination.

     

    Floor Stand And Castor Wheels

    Floor Stand is made up of heavy duty tubular pipe duly powder coated and fitted with durable castor wheels for rotation and total brake system on front wheels.

     

    Magnehelic Gauge

    Magnehelic Gauge Differential Pressure Gauge (0 – 50 mm: 1 No.) monitor differential pressure across HEPA Filter with respect to ambient. Magnehelic Differential Pressure Gauge to monitor pressure drop across Workarea with respect to ambient.

     

    Emergency Stop

    Emergency switch for any emergency situation

     

    Controller

    • ALL SYSTEM AND CONTROL THROUGH A 3.5” TOUCH SCREEN LCD DISPLAY WITH IN-BUILT DATA LOGGING (REAL TIME) AND USB PORT ON FRONT FACIA FOR DATA DOWNLOAD FOR FURTHER TRANSFER TO PC.
    • Audio – visual alarm for blower tripping and fault acknowledgement.
    • Alarm triggers in case front door is raised more than 8” (i.e. safe clear opening during operation)
    • U. V. Light with Hour Meter & interlocking arrangement to put off U. V. light if either side door opens
    • UV Light with Hour Meter
    • Alarm for front door of BSC for safe clear opening

     

    Options:

    • Magnehelic Pressure Differential Gauge (To track filter pressure in lieu of static pressure manometer).
    • Electronic filter choke alarm (Differential Pressure Monitor).
    • Exhaust ducting per running feet.
    • Gas Burner.
    • Spare U.V. Germicidal Tube (1.5 feet).
    • Spare U.V. Germicidal Tube (3.0 feet).


    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Pro Plus Class II Type A2 Biological Safety Cabinet?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice