    Pro Plus Class II Type B2 Biological Safety Cabinet

    • Country of OriginIndia
    • Brand NameMAC
    • Heavy Duty Exhause SystemStandard Fitted to the System for 100% Exhaust
    • Sash LiftCan Be Lifted and Adjusted Manually
    • Supply TypeExporter, Supplier
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    location Somwar Peth, Pune, Maharashtra
    4.5/5fill iconfill iconfill iconfill iconhalf icon(20)
    View Number
    • calendar Member Since 10 Years
    • building Nature of Business Trader
    • gst icon GST No. 27AABFJ1118P1ZA

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • Country of OriginIndia
    • Heavy Duty Exhause SystemStandard Fitted to the System for 100% Exhaust
    • Brand NameMAC
    • Power Supply220/230 Volts AC supply
    • Sash LiftCan Be Lifted and Adjusted Manually
    • Electrical SocketElectrical Socket is Provided for Using Small Electrical Devices

    Features:

    • 100 % air exhaust
    • Negative pressure air surrounding all biological contaminated parts
    • Class II, Type B2 cabinets are total exhaust cabinets, widely used in toxicology laboratories and similar applications where chemical effluent is present and clean air is essential.
    • There is no recirculation within the work area.
    • Room air enters through a blower/motor in the top of the cabinet and passes through a HEPA supply filter into the work area as the vertical unidirectional airflow.
    • Descending air is pulled through the base of the cabinet through the perforated front and rear grilles.
    • Simultaneously, air entering through the perforated front opening is pulled through the grille and exhausted immediately,
    • 100% of the air is pulled into the facility exhaust system for appropriate treatment.
    • Type B2 cabinet is hard-connected to an exhaust system.
    • Negative pressure surrounds the work area with double-wall plenums for protection.
    • Air drawn through pre-filter is made to pass through highly effective HEPA (High-Efficiency Particular Air) filters. The prefilter fitted extends the life of the HEPA filter drastically. Fitted with HEPA Filter made from water-resistant, fire retardant, imported microfine glass fiber media; conforms to EU - 14 Grade, with an efficiency rating better than 99.999% for 0.3 μ. These filters are designed to accommodate higher air flow volume.
    • Prefilter is made from Non-Woven Synthetic with HDPE mesh and Al expanded mesh on the air leaving side; conforms to EU-4 /G-4 Grade, with the efficiency of down to 10 microns. These filters can be cleaned by compressed air & also washable.
    • Mounted on heavy tubular stand with lockable castors.
    • Aerodynamic airflow grills maintain safety and prevents blockage.
    • U.V and fluorescent interlock available
    • Ergonomic and comfortable sloped front window for comfortable head and elbow rest position, thus reducing fatigue
    • Sash is counterbalanced for smooth and lightweight operation with a standard opening for easier access to the work zone and enhanced user safety.
    • CLASS-II design ensures PERSONNEL, PRODUCT and ENVIRONMENT PROTECTION.

     

    Cass II Biosafety Cabinet Protection

    • Personnel protection from harmful agents used inside the biosafety cabinet.
    • Product protection to avoid contamination of the works, experiment or process from outside contaminants.
    • Environmental protection from contaminants contained within the biosafety cabinet.

     

    Cass II Biosafety Cabinet Key Features

    • A front access opening with carefully maintained inward airflow.
    • HEPA-filtered, vertical, unidirectional airflow within the work area.
    • HEPA-filtered exhaust air to the room or exhaust to a facility exhaust system.

     

    Cass II Biosafety Key Applications

    • Typically used for biosafety levels 1 through 3 for low to moderate risk biological agents.
    • The type B2 total exhaust cabinets are widely used in toxicology laboratories and similar applications where chemical effluent is present and clean air is essential.
    • All types of Class II cabinets may be used in biosafety level 4 laboratories when workers utilize positive pressure suits. However, for level 4 Class III cabinets are recommended.
    • Upper & Front Cover
    • Removable upper and front cover simplifies filter, blower and front control panel replacements and maintenance easier.

     

    Material Of Construction

    Working Table is made up of Stainless Steel (SS-304). External Cabinet is fabricated of electrogalvanized powder coated OR Stainless Steel (SS-304) (as ordered).

     

    Front Window/Sash

    Front Sash consists of a thick plexi-glass or toughened transparent glass (Option) for a clear inside view. In addition it serves optimum resistance and protection from harmful UV rays, protection user from exposure to harmful Ultraviolet radiation.

     

    Drain Trough With Valve

    The trough at base is easy to clean and for offloading liquid spillage if any.

     

    Decontamination By UV Lamp

    UV Lamp to produce UV rays of 253.7 nanometers and fluorescent lamp are interlocked and the motor blower is turned off/on as and when the front sash is closed/opened. UV lamps function through a timer (Option) to control the decontamination cycle and maximize UV lamp life. The UV lamp shuts off once the desired set time of decontamination is over and switches the fluorescent lamp to ON position.

     

    Splash Proof Electric Supply Socket

    Splash proof sockets is provided for optimum convenience of using small electrical devices inside the cabinet.

     

    Front Airflow Intake Grid

    Aerodynamically designed front airflow intake grid eliminates potential turbulence and contamination.

     

    Floor Stand And Castor Wheels

    Floor Stand is made up of heavy-duty tubular pipe duly powder coated and fitted with durable castor wheels for rotation and total brake system on front wheels.

     

    Controller

    • All system and control through a 3.5” touch screen LCD display with in-built data logging (real-time) and USB port on front facia for data download for further transfer to pc.
    • Audiovisual alarm for blower tripping and fault acknowledgment.
    • Alarm triggers in case front door is raised more than 8” (i.e. safe clear opening during operation)
    • U. V. Light with Hour Meter & interlocking arrangement to put off U. V. light if either side door opens
    • UV Light with Hour Meter
    • Alarm for the front door of BSC for safe clear opening

     

    Options

    • Magnehelic Pressure Differential Gauge (To track filter pressure in lieu of static pressure manometer).
    • Electronic filter choke alarm (Differential Pressure Monitor).
    • Exhaust ducting per running feet.
    • Gas Burner.
    • Spare U.V. Germicidal Tube (1.5 feet).
    • Spare U.V. Germicidal Tube (3.0 feet).


    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Pro Plus Class II Type B2 Biological Safety Cabinet?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice