    • Brand NameRish
    • Fuse500 Ma(f) / 440 H.b.c. 10ka Min (32mm X 6mm)
    • Storage Temp-25 °c to ++65 °c
    • Temp. Coefficient<0.1% per °c
    • Supply TypeManufacturer, Exporter, Supplier, Retailer, Trader
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 6 Years
    • building Nature of Business Supplier
    • gst icon GST No. 24ASGPP1450M1ZM

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • Brand NameRish
    • Storage Temp-25 °c to ++65 °c
    • Fuse500 Ma(f) / 440 H.b.c. 10ka Min (32mm X 6mm)
    • Battery6 X 1.5 V Cells Iec Lr6 Non-rechargeable Cells
    • Temp. Coefficient<0.1% per °c
    • Coltage MeasurementAc (sine), 50/60 Hz
    • Relative Humidity90% Rh At 40°c Max.

    Analog + Digital Display (Log scale for Insulation Measurement)
    The Analog scale for insulation resistance measurement is logarithmic in nature which gives the dynamic performance of an analog insulation tester. The Analog scale is linear for low ohm and voltage measurement.
     
    User Selectable Backlit Display
    The instrument is provided with user selectable backlit for taking measurements in dark areas/poor lighting conditions.
     
    Connector jack for External Mains Adapter (Optional)
    The instrument can be operated from mains supply (230V AC) instead of batteries using an external mains adapter (230V AC/9V DC, 500mA (4.5VA) isolated)
     
    Test Voltages 50V/100V/250V/500V/1000V
    Test voltages from 50V to 1000V can be selected for insulation resistance measurement. It covers all insulation tests up to 1000V.
     
    Insulation Resistance Measurement
    The instrument is capable of measuring insulation resistance from10kOhm…2GOhm.
     
    Low Resistances Measurement (0.01Ohm... 99.9 Ohm)
    Low resistances can be measured up to 99.9Ohm. There are two measuring ranges for Low Ohm : 9.99Ohm and 99.9Ohm.
     
    Hands-free continuity testing
    Continuity testing (0-10Ohm with acoustic signal) can be done without pressing the test button. In addition to the display function, an acoustic signal can be activated which sounds if the adjustable limit value is violated.
     
    Voltmeter
    Instrument measures voltages >25V … 600V AC/DC
     
    Automatic discharge for capacitive circuits after test measurement
    Capacitive devices under test, such as cables and windings that get charged during the test are discharged by the tester.
     
    Live circuit detection
    Displays presence of voltages >25V irrespective of function selected.
     
    Blown fuse indication
    The display FUSE points to a blown fuse.
     
    Pre-selectable measurement time for Insulation Resistance Measurement
    In normal course, the insulation test terminates and the measured insulation resistance value remains on display for 2 sec after the test key is released. With the Pre-selectable measurement time feature, the insulation test continues and the measured value remains on the display for the pre-determined time. Pre-selectable time: 10 sec - 5 min.
     
    Pre-selectable limit checks (Go/ No-go option) for MOhm / GOhm
    An acoustic signal can be generated when the measured value of insulation resistance falls below an adjustable limit value.
     
    Lead resistance null facility
    The instrument provides a facility to compensate the resistance of the leads for an accurate measurement of low resistances.
     
    Storage of MIN / MAX values
    In addition to the display of the actual measured value, the minimum or maximum value can constantly be updated or stored.
     
    Storage Memory for last 10 readings
    The instrument provides a facility to store and recall 10 values in each of the 5 ranges of insulation resistance measurement, continuity and resistance measurement.
     
    Stop Watch
    This function allows you to measure elapsed time up to 1 hour.
     
    Auto-power off function
    The instrument turns off automatically, if any of the keys or the selector switch have not been activated for about 10 minutes in insulation range and 5 minutes in other ranges or can be switched to continuous operation.
     
    Protective holster for rough duty
    A holster of soft rubber with tilt stand protects the meter against damage in case of shock and drop.


    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Insu 20 Insulation Tester?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice