Company Information
Ask for more detail from the seller
Contact Supplierwe have carved a niche in the market as the manufacturer, repairer & supplier of stainless steel s type load cells. we are based in maharashtra, india. the s type load cells we offer are used for conversion systems in various industries. we check the s type load cells on stringent quality parameters before the final delivery. buyers can acquire the s type load cells from us at reasonable prices.
applications :
suspended hooper weighing force measurement, tension/ compression, tensile testing, material testing, hybrid scale, crane scale, process weighting, industrial automation.
| All Dimensions are in MM | ||||
| Capacity | Height | Length | Width | Thread |
| 2 kg to 50 kg. | 75 | 50 | 16 | M-8 |
| 100 kg to 750 kg. | 75 | 50 | 20 | M-10 |
| 1 T to 5 T | 100 | 75 | 35 | M-20 |
| 7.5 to 10 Ton | 175 | 125 | 50 | M-33 |
| 15 T, 20 T | 175 | 125 | 70 | M-42 |
| 30 T | 230 | 190 | 85 | M-42 |
| ||||
| O/P | 2 mV/V # | |||
| Non Linearity | < ± 0.02%of Rated Load | |||
| Repeatability | < ± 0.02%of Rated Load | |||
| Hysteresis | < ± 0.02%of Rated Load | |||
| Creep@30 Min. | < ± 0.02%of Rated Load | |||
| Zero Balance | < ± 2%of Rated Load | |||
| Total Error | < ± 0.03% of Rated Load | |||
| I/P Impedance | 417 Ohms ± 15 Ohms | |||
| O/P impedance | 350 Ohms ±5ohms | |||
| Insulation Impedance | 1000 M Ohms@50VDC | |||
| Service Load | 100% of Rated Load | |||
| Safe Over Load | 150% of Rated Load | |||
| Ultimate Over Load | 200% of Rated Load | |||
| Tempt. Effect on Zero | < 0.002% of Rated Load /°C | |||
| Tempt. Effect on O/P | < 0.002% of Rated Load /°C | |||
| Deflection | <0.5 mm at Full load | |||
| # 3mV/V Optional | ||||