Company Information
Ask for more detail from the seller
Contact SupplierApplication : Ideal for agricultural greenhouse power stations, shery water power stations, and rooftop power stations of industrial and commercial buildings
Superior Eciency for Increased Protability
High Reliability with Reduced Investment
User-friendly Installation and Intelligent Maintenancee
| Model | SE 2KTL | SE 3KTL |
|---|---|---|
| Eciency | ||
| Max. Eciency | 99.00% | 99.00% |
| European Eciency | 98.50% | 98.50% |
| Input(DC) | ||
| Max. DC Usable Power | 60,000W | 72,000W |
| Max. Input Voltage | 1100V | 1100V |
| Max. Input Current | 110A (33/33/22/22) | 132A (33/333/33/33) |
| Min. Operating Voltage/Start Input Voltage | 200V/250V | 200V/250V |
| MPPT Operating Voltage Range | 200V-950V | 200V-950V |
| MPPT Operating Voltage Range (Full -Load) | 540V-850V | 540V-850V |
| Max. Number of PV Strings | 10(3/3/2/2) | 12(3/3/3/3) |
| No. of MPPTs | 4 | 4 |
| Output(AC) | ||
| Rated AC Active Power | 50,000W | 60,000W |
| Max. AC Apparent Power | 55,000VA | 66,000VA |
| Max. AC Active Power (PF=1) | 50,000W | 66,000W |
| Max. AC Output Current | 83A | 92A |
| Rated AC Voltage | 380V, 3W+N+PE | 380V, 3W+N+PE |
| AC Voltage Range* | 277Vac-520Vac (adjustable) | 277Vac-520Vac (adjustable) |
| Rated Grid Frequency | 50Hz/60Hz | 50Hz/60Hz |
| Grid Frequency Range** | 45Hz-55Hz/55Hz-65H | 45Hz-55Hz/55Hz-65Hz |
| THDI | <3% | <3% |
| DC Current Injection | <0.5%In | <0.5%In |
| Power Factor | > 0.99 rated power (adjistable 0.8 LD - 0.8 LG) | |
| Protection | ||
| DC switch | support | |
| Anti-islanding protection | support | |
| AC overcurrent protection | support | |
| AC short circuit protection | support | |
| DC reverse connection | support | |
| Surge Arrester | AC Type Ill | |
| Insulation detection | support | |
| Leakage current protection | support | |
| Anti-PID Function | Optional | |
| General | ||
| Topology | Transformerless | |
| IP Rating | IP65 | |
| Cooling | Fan cooling | |
| Operating Temperature Range | -25°C-60°C | |
| Relative Humidity Range | 0-100% | |
| Max. Operating Altitude | 4000m | |
| Noise | <50dB | |
| Dimensions (W*H*D) | 855mm*555mm*275mm | |
| Weight | 65kg | 67kg |
| HMI & COM | ||
| Display | Blue-tooth & LED indicator, LCD (optional) | |
| Communication | RS485, WIFI (optional), GPRS(optional) | |
| Certification | ||
| Safety | IEC62109-1, IEC62109-2 | |
| EMC | EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12 | |
| Grid Code | VDE-AR-N 4105, IEC 61727 | |
Remarks The range of output voltage and frequency may vary depending upon dierent grid codes. Specications are subject to change without advancenotice.