Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    Siemens - (6ag1222-1hf30-2xb0), Siplus - (s7-1200 Sm1222 8rly Conformal Coating)

    ₹ 17,215.82 / 181 181 Piece
    Get Latest Price
    • MOQ1 Piece(s)
    • TYPEPLC
    • Brand NameSiemens
    • Supply TypeExporter
    • Preferred Buyer Location All over the world

    Supply voltage permissible range, lower limit (dc) 5 v permissible range, upper limit (dc) 30 v input current from backplane bus 5 v dc, max. 120 ma digital inputs from load voltage l+ (without....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 13 Years
    • building Nature of Business Exporter
    • Year of Establishment 2000

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    Supply voltage
    permissible range, lower limit (dc) 5 v
    permissible range, upper limit (dc) 30 v
    input current
    from backplane bus 5 v dc, max. 120 ma
    digital inputs
    from load voltage l+ (without load), max. 11 marelay coil
    power losses
    power loss, typ. 4.5 w
    digital inputs
    numberbinary inputs 0
    digital outputs
    numberbinary outputs 8
    in groups of 2
    functionalityshort-circuit strength no; to be provided externally
    switching capacity of the outputs
    with resistive load, max. 2 a
    on lamp load, max. 30 w dc ; 200 w ac
    output voltage
    rated value (ac) 5 to 250 v ac
    rated value (dc) 5 to 30 v dc
    output current
    for signal "1" permissible range, max. 2 a
    output delay with resistive load
    0 to "1", max. 10 ms
    1 to "0", max. 10 ms
    aggregate current of outputs (per group)
    horizontal installation
    up to 50 °c, max. 10 a; current per mass
    relay outputs
    number of relay outputs 8
    rated input voltage of relay coil l+ (dc) 24 v
    number of operating cycles, max. Mechanically 10 million, at rated load voltage 100,000
    switching capacity of contacts
    with inductive load, max. 2 a
    on lamp load, max. 30 w dc ; 200 w ac
    switching frequencycontactsat ohmic loadmaximum 2 a
    cable length
    cable length, shielded, max. 500 m
    cable length unshielded, max. 150 m
    interruptsdiagnosticsstatus information
    alarms
    alarms yes
    diagnostic alarm yes
    diagnostic messages
    diagnostic functions yes
    diagnostics indication led
    for status of the outputs yes
    for maintenance yes
    status indicator digital output (green) yes
    galvanic isolation
    galvanic isolation digital outputs
    between the channels relay
    between the channels, in groups of 2
    between the channels and the backplane bus 1500 v ac for 1 minute
    degree and class of protection
    ip20 yes
    standards, approvals, certificates
    ce mark yes
    fm approval yes
    ambient conditions
    extended ambient conditions
    relative to ambient temperature-atmospheric pressure-installation altitude tmin . Tmax at 1080 hpa ... 795 hpa (-1000 m ... +2000 m) tmin ... (tmax - 10k) at 795 hpa ... 658 hpa (+2000 m ... +3500 m) tmin ... (tmax - 20k) at 658 hpa ... 540 hpa (+3500 m ... +5000 m)
    relative humidity
    with condensation maximum 100 %; relative humidity, incl. Condensation frost permitted (no commissioning under condensation conditions)
    resistance
    to biologically active substances conformity with en 60721-3-3 yes; , class 3b2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
    to chemically active substances conformity with en 60721-3-3 yes; , class 3c4 incl. Salt spray. The supplied connector covers must remain on the unused interfaces during operation!
    to mechanically active substances conformity with en 60721-3-3 yes; , class 3s4 incl. Sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
    climatic and mechanical conditions for storage and transport
    climatic conditions for storage and transport
    free fall
    drop height, max. (in packaging) 0.3 m; five times, in dispatch package
    temperature
    permissible temperature range -40 °c to +70 °c
    mechanical and climatic conditions during operation
    climatic conditions in operation
    temperature
    min. -25 °c; = tmin
    max. 70 °c; = tmax
    connection method
    required front connector yes
    mechanicsmaterial
    type of housing (front)
    plastic yes
    dimensions
    width 45 mm
    height 100 mm
    depth 75 mm
    weight
    weight, approx. 190 g


    Additional Information

    • Payment Terms T/TWestern Union
    • Port of DispatchShenzhen
    • Packaging Details100% Siemens Original and New. Standard Air Conditioning Packing
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for Siemens - (6ag1222-1hf30-2xb0), Siplus - (s7-1200 Sm1222 8rly Conformal Coating)?

    Quantity
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice